Tao Luo, Dezheng Zhang, Kui Wang, Zhenchuan Ma, Wenbo Xuan, Haozhong Cheng
{"title":"特高压交流一体化电网无功规划研究","authors":"Tao Luo, Dezheng Zhang, Kui Wang, Zhenchuan Ma, Wenbo Xuan, Haozhong Cheng","doi":"10.1109/ICPES56491.2022.10072580","DOIUrl":null,"url":null,"abstract":"URV AC transmission has the characteristics of large capacity, long distance, low loss and effective utilization of transmission corridor. It is an inevitable choice for the development of power grid in China. The operation of UHV AC system will have a considerable impact on the operation economy and stability of power grid, and also put forward new requirements for reactive power planning. In this paper, a two-stage reactive power planning model is proposed, in which the first-stage reactive power planning model aims at the minimization of system operation cost, active power loss and traversing reactive power under normal conditions. The second-stage model is to obtain the optimal reactive power planning scheme with the goal of minimizing the investment cost and the constraint of voltage stability margin under severe faults based on the first-stage planning scheme. Finally, the effectiveness of this model is verified through numerical results.","PeriodicalId":425438,"journal":{"name":"2022 12th International Conference on Power and Energy Systems (ICPES)","volume":"191 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on Reactive Power Planning for Power Grid with the Integration of UHV AC System\",\"authors\":\"Tao Luo, Dezheng Zhang, Kui Wang, Zhenchuan Ma, Wenbo Xuan, Haozhong Cheng\",\"doi\":\"10.1109/ICPES56491.2022.10072580\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"URV AC transmission has the characteristics of large capacity, long distance, low loss and effective utilization of transmission corridor. It is an inevitable choice for the development of power grid in China. The operation of UHV AC system will have a considerable impact on the operation economy and stability of power grid, and also put forward new requirements for reactive power planning. In this paper, a two-stage reactive power planning model is proposed, in which the first-stage reactive power planning model aims at the minimization of system operation cost, active power loss and traversing reactive power under normal conditions. The second-stage model is to obtain the optimal reactive power planning scheme with the goal of minimizing the investment cost and the constraint of voltage stability margin under severe faults based on the first-stage planning scheme. Finally, the effectiveness of this model is verified through numerical results.\",\"PeriodicalId\":425438,\"journal\":{\"name\":\"2022 12th International Conference on Power and Energy Systems (ICPES)\",\"volume\":\"191 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 12th International Conference on Power and Energy Systems (ICPES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPES56491.2022.10072580\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 12th International Conference on Power and Energy Systems (ICPES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPES56491.2022.10072580","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research on Reactive Power Planning for Power Grid with the Integration of UHV AC System
URV AC transmission has the characteristics of large capacity, long distance, low loss and effective utilization of transmission corridor. It is an inevitable choice for the development of power grid in China. The operation of UHV AC system will have a considerable impact on the operation economy and stability of power grid, and also put forward new requirements for reactive power planning. In this paper, a two-stage reactive power planning model is proposed, in which the first-stage reactive power planning model aims at the minimization of system operation cost, active power loss and traversing reactive power under normal conditions. The second-stage model is to obtain the optimal reactive power planning scheme with the goal of minimizing the investment cost and the constraint of voltage stability margin under severe faults based on the first-stage planning scheme. Finally, the effectiveness of this model is verified through numerical results.