高频传导扰动对变频感应电动机匝间绝缘的影响

R. Candela, C. Petrarca, P. Romano
{"title":"高频传导扰动对变频感应电动机匝间绝缘的影响","authors":"R. Candela, C. Petrarca, P. Romano","doi":"10.1109/CEIDP.2003.1254904","DOIUrl":null,"url":null,"abstract":"As shown in recent papers, Partial Discharge activity has a fundamental role in the premature failure of electrical insulation of machine stator windings fed by PWM inverters. The existence of Partial Discharges can be easily explained if the presence of micro voids inside a composite insulation is considered to be unavoidable. Since such micro cavities are filled with a gas whose permittivity is generally several times lower than the permittivity of the surrounding dielectric, the electric field in such occlusions can be much higher than the local expected average stress. On the basis of a numerical study carried out by using a multi conductor transmission line model for the evaluation of the potential distribution inside the machine and a PD simulation model for the evaluation of the possible ensuing PD activity, in this paper, a new experimental approach to evaluate the effect of PD generated by inverter distorted voltages is proposed. PD measurements under 50 Hz -10 kHz quasi-square and sine wave voltage waveform are performed by means of an Hv capacitive bridge measurement system in order to reject external disturbances, like voltage overshoots, and they are acquired by ultra-wide band (UWB) acquisition system.","PeriodicalId":306575,"journal":{"name":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Effect of high frequency conducted disturbances on the interturn insulation of an inverter-fed induction motor\",\"authors\":\"R. Candela, C. Petrarca, P. Romano\",\"doi\":\"10.1109/CEIDP.2003.1254904\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As shown in recent papers, Partial Discharge activity has a fundamental role in the premature failure of electrical insulation of machine stator windings fed by PWM inverters. The existence of Partial Discharges can be easily explained if the presence of micro voids inside a composite insulation is considered to be unavoidable. Since such micro cavities are filled with a gas whose permittivity is generally several times lower than the permittivity of the surrounding dielectric, the electric field in such occlusions can be much higher than the local expected average stress. On the basis of a numerical study carried out by using a multi conductor transmission line model for the evaluation of the potential distribution inside the machine and a PD simulation model for the evaluation of the possible ensuing PD activity, in this paper, a new experimental approach to evaluate the effect of PD generated by inverter distorted voltages is proposed. PD measurements under 50 Hz -10 kHz quasi-square and sine wave voltage waveform are performed by means of an Hv capacitive bridge measurement system in order to reject external disturbances, like voltage overshoots, and they are acquired by ultra-wide band (UWB) acquisition system.\",\"PeriodicalId\":306575,\"journal\":{\"name\":\"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2003.1254904\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2003.1254904","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

正如最近的论文所示,局部放电活动在PWM逆变器供电的机器定子绕组电气绝缘过早失效中起着根本作用。局部放电的存在可以很容易地解释,如果存在的微空洞的复合绝缘被认为是不可避免的。由于这种微腔中充满的气体的介电常数通常比周围介质的介电常数低几倍,因此这种闭塞中的电场可能远远高于局部预期的平均应力。本文在采用多导体传输线模型评估机内电位分布和采用局部放电仿真模型评估可能的局部放电活度的数值研究基础上,提出了一种新的实验方法来评估逆变器畸变电压产生局部放电的影响。在50 Hz -10 kHz的准方波和正弦波电压波形下,通过高压电容式电桥测量系统进行PD测量,以抑制电压过调等外部干扰,并通过超宽带(UWB)采集系统进行PD测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of high frequency conducted disturbances on the interturn insulation of an inverter-fed induction motor
As shown in recent papers, Partial Discharge activity has a fundamental role in the premature failure of electrical insulation of machine stator windings fed by PWM inverters. The existence of Partial Discharges can be easily explained if the presence of micro voids inside a composite insulation is considered to be unavoidable. Since such micro cavities are filled with a gas whose permittivity is generally several times lower than the permittivity of the surrounding dielectric, the electric field in such occlusions can be much higher than the local expected average stress. On the basis of a numerical study carried out by using a multi conductor transmission line model for the evaluation of the potential distribution inside the machine and a PD simulation model for the evaluation of the possible ensuing PD activity, in this paper, a new experimental approach to evaluate the effect of PD generated by inverter distorted voltages is proposed. PD measurements under 50 Hz -10 kHz quasi-square and sine wave voltage waveform are performed by means of an Hv capacitive bridge measurement system in order to reject external disturbances, like voltage overshoots, and they are acquired by ultra-wide band (UWB) acquisition system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The effect of temperature and the mutual influence between two cavities of on the appearance of partial discharges in gaseous cavities contained in the insulator of high voltage Breakdown strength at the interface between epoxy resin and silicone rubber Surface change of polyamide nanocomposite caused by partial discharges Surface finish effects on partial discharge with embedded electrodes Roles of cumyl alcohol and crosslinked structure in homo-charge trapping in crosslinked polyethylene
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1