{"title":"欠压保护在关键电机中的应用","authors":"M. Proctor","doi":"10.1109/CPRE.2018.8349774","DOIUrl":null,"url":null,"abstract":"Undervoltage protection is commonly used to protect motors from damage during abnormal conditions and to prevent breaker-fed motors from re-accelerating after a restoration of bus voltage. This protection method has the unfortunate consequence of introducing the possibility of a nuisance trip when VT's fail. This paper explores fundamentals of under voltage protection as well as pros and cons of different methods that can be deployed to prevent VT failure from causing costly outages. Case studies will be presented as well as methods which include both monitoring of hardwired VT status contacts and internal relay algorithms.","PeriodicalId":285875,"journal":{"name":"2018 71st Annual Conference for Protective Relay Engineers (CPRE)","volume":"68 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Application of undervoltage protection to critical motors\",\"authors\":\"M. Proctor\",\"doi\":\"10.1109/CPRE.2018.8349774\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Undervoltage protection is commonly used to protect motors from damage during abnormal conditions and to prevent breaker-fed motors from re-accelerating after a restoration of bus voltage. This protection method has the unfortunate consequence of introducing the possibility of a nuisance trip when VT's fail. This paper explores fundamentals of under voltage protection as well as pros and cons of different methods that can be deployed to prevent VT failure from causing costly outages. Case studies will be presented as well as methods which include both monitoring of hardwired VT status contacts and internal relay algorithms.\",\"PeriodicalId\":285875,\"journal\":{\"name\":\"2018 71st Annual Conference for Protective Relay Engineers (CPRE)\",\"volume\":\"68 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-03-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 71st Annual Conference for Protective Relay Engineers (CPRE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPRE.2018.8349774\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 71st Annual Conference for Protective Relay Engineers (CPRE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPRE.2018.8349774","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Application of undervoltage protection to critical motors
Undervoltage protection is commonly used to protect motors from damage during abnormal conditions and to prevent breaker-fed motors from re-accelerating after a restoration of bus voltage. This protection method has the unfortunate consequence of introducing the possibility of a nuisance trip when VT's fail. This paper explores fundamentals of under voltage protection as well as pros and cons of different methods that can be deployed to prevent VT failure from causing costly outages. Case studies will be presented as well as methods which include both monitoring of hardwired VT status contacts and internal relay algorithms.