{"title":"中压OIP套管状态监测试验技术","authors":"Suthat Suksagoolpanya, N. Pattanadech","doi":"10.1109/ICEAST52143.2021.9426285","DOIUrl":null,"url":null,"abstract":"A bushing is one of the most important parts of a transformer. Failure of the bushing may cause the transformer destruction, which can lead to the failure of the electrical power system. Therefore the insulation monitoring of the bushings is essential.This paper investigates the approximate 30 years in serviced medium voltage bushings. The 5 units of aged and deteriorated bushings were removed from the electrical power system, and the electrical testing was performed. The electrical testing included the insulation power factor (IPF) testing and the polarization and depolarization current measurement (PDC).The test results showed that the IPF of the main insulation was increased approximately 1-10 times from the nameplate values and the initial currents of PDC measurement were high for all bushings compared with initial currents of PDC measurement of the good bushing insulation condition from the database. From the test results, the combined test techniques between the power factor testing and the PDC measurement provided useful data for the insulation condition diagnosis of the service bushings.","PeriodicalId":416531,"journal":{"name":"2021 7th International Conference on Engineering, Applied Sciences and Technology (ICEAST)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Condition Monitoring Test Techniques for Medium Voltage OIP Bushings\",\"authors\":\"Suthat Suksagoolpanya, N. Pattanadech\",\"doi\":\"10.1109/ICEAST52143.2021.9426285\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A bushing is one of the most important parts of a transformer. Failure of the bushing may cause the transformer destruction, which can lead to the failure of the electrical power system. Therefore the insulation monitoring of the bushings is essential.This paper investigates the approximate 30 years in serviced medium voltage bushings. The 5 units of aged and deteriorated bushings were removed from the electrical power system, and the electrical testing was performed. The electrical testing included the insulation power factor (IPF) testing and the polarization and depolarization current measurement (PDC).The test results showed that the IPF of the main insulation was increased approximately 1-10 times from the nameplate values and the initial currents of PDC measurement were high for all bushings compared with initial currents of PDC measurement of the good bushing insulation condition from the database. From the test results, the combined test techniques between the power factor testing and the PDC measurement provided useful data for the insulation condition diagnosis of the service bushings.\",\"PeriodicalId\":416531,\"journal\":{\"name\":\"2021 7th International Conference on Engineering, Applied Sciences and Technology (ICEAST)\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 7th International Conference on Engineering, Applied Sciences and Technology (ICEAST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEAST52143.2021.9426285\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 7th International Conference on Engineering, Applied Sciences and Technology (ICEAST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEAST52143.2021.9426285","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

套管是变压器最重要的部件之一。套管的失效可能会造成变压器的破坏,从而导致电力系统的故障。因此,对套管的绝缘监测是必不可少的。本文对服役中压轴套进行了近30年的研究。将老化变质的5套衬套从电力系统中拆下,并进行电气试验。电气测试包括绝缘功率因数(IPF)测试和极化与去极化电流测量(PDC)。试验结果表明,主绝缘的IPF比铭牌值提高了约1-10倍,与数据库中绝缘条件良好的套管的PDC测量初始电流相比,所有套管的PDC测量初始电流都高。从试验结果来看,功率因数测试与PDC测量相结合的测试技术为服役套管的绝缘状态诊断提供了有用的数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Condition Monitoring Test Techniques for Medium Voltage OIP Bushings
A bushing is one of the most important parts of a transformer. Failure of the bushing may cause the transformer destruction, which can lead to the failure of the electrical power system. Therefore the insulation monitoring of the bushings is essential.This paper investigates the approximate 30 years in serviced medium voltage bushings. The 5 units of aged and deteriorated bushings were removed from the electrical power system, and the electrical testing was performed. The electrical testing included the insulation power factor (IPF) testing and the polarization and depolarization current measurement (PDC).The test results showed that the IPF of the main insulation was increased approximately 1-10 times from the nameplate values and the initial currents of PDC measurement were high for all bushings compared with initial currents of PDC measurement of the good bushing insulation condition from the database. From the test results, the combined test techniques between the power factor testing and the PDC measurement provided useful data for the insulation condition diagnosis of the service bushings.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Mobile Application for Basic Computer Troubleshooting using TensorFlow Lite Exploitation of IoTs for PMU in Tethered Drone Multi-Tier Model with JSON-RPC in Telemedicine Devices Authentication and Authorization Protocol Neuro-fuzzy Model with Neighborhood Component Analysis for Air Quality Prediction Extremely Low-Power Fifth-Order Low-Pass Butterworth Filter
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1