敏感人根状牙本质形态学特征及光固化树脂衬套对管状牙合的影响。

M Yoshiyama, K Ozaki, S Ebisu
{"title":"敏感人根状牙本质形态学特征及光固化树脂衬套对管状牙合的影响。","authors":"M Yoshiyama,&nbsp;K Ozaki,&nbsp;S Ebisu","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A dentin biopsy technique was employed to compare the morphological features of hypersensitive and non-sensitive human radicular dentin. Specimens sampled from different areas in the same root surface displaying hypersensitivity or non-sensitivity were prepared for examination in the scanning electron microscope (SEM). Before analysis some specimens were exposed to surface demineralization and digestion of collagen to allow observation of subsurface portions of the dentinal tubules. In another set of observations the potential of a light-curing resin liner to penetrate root dentin in vitro and to maintain tubular occlusion over time following treatment of hypersensitive radicular dentin were examined. Orifices of many dentinal tubules were open in hypersensitive regions while non-sensitive areas generally displayed tubules occluded with mineralized material. SEM-images of HCl-collagenase treated specimens demonstrated the frequent presence of membrane-like structures in tubules of hypersensitive dentin. In non-sensitive dentin these structures were sparse. Topical application of a light-curing resin liner to wedge shaped defects prepared in radicular dentin of extracted human teeth resulted in a surface coating with a resin thickness of 20-50 microns. Resin penetrated dentinal tubules to a depth of more than 5 microns. Dentin biopsies examined 6 months after treatment with the liner showed presence of resin-like material in a majority of the tubules in dentin where hypersensitivity was no longer perceived. In none of the specimens did the liner remain as a surface coating. In areas of recurrent hypersensitivity more than half of the tubules presented with open orifices.(ABSTRACT TRUNCATED AT 250 WORDS)</p>","PeriodicalId":76355,"journal":{"name":"Proceedings of the Finnish Dental Society. Suomen Hammaslaakariseuran toimituksia","volume":"88 Suppl 1 ","pages":"337-44"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Morphological characterization of hypersensitive human radicular dentin and the effect of a light-curing resin liner on tubular occlusion.\",\"authors\":\"M Yoshiyama,&nbsp;K Ozaki,&nbsp;S Ebisu\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A dentin biopsy technique was employed to compare the morphological features of hypersensitive and non-sensitive human radicular dentin. Specimens sampled from different areas in the same root surface displaying hypersensitivity or non-sensitivity were prepared for examination in the scanning electron microscope (SEM). Before analysis some specimens were exposed to surface demineralization and digestion of collagen to allow observation of subsurface portions of the dentinal tubules. In another set of observations the potential of a light-curing resin liner to penetrate root dentin in vitro and to maintain tubular occlusion over time following treatment of hypersensitive radicular dentin were examined. Orifices of many dentinal tubules were open in hypersensitive regions while non-sensitive areas generally displayed tubules occluded with mineralized material. SEM-images of HCl-collagenase treated specimens demonstrated the frequent presence of membrane-like structures in tubules of hypersensitive dentin. In non-sensitive dentin these structures were sparse. Topical application of a light-curing resin liner to wedge shaped defects prepared in radicular dentin of extracted human teeth resulted in a surface coating with a resin thickness of 20-50 microns. Resin penetrated dentinal tubules to a depth of more than 5 microns. Dentin biopsies examined 6 months after treatment with the liner showed presence of resin-like material in a majority of the tubules in dentin where hypersensitivity was no longer perceived. In none of the specimens did the liner remain as a surface coating. In areas of recurrent hypersensitivity more than half of the tubules presented with open orifices.(ABSTRACT TRUNCATED AT 250 WORDS)</p>\",\"PeriodicalId\":76355,\"journal\":{\"name\":\"Proceedings of the Finnish Dental Society. Suomen Hammaslaakariseuran toimituksia\",\"volume\":\"88 Suppl 1 \",\"pages\":\"337-44\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Finnish Dental Society. Suomen Hammaslaakariseuran toimituksia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Finnish Dental Society. Suomen Hammaslaakariseuran toimituksia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用牙本质活检技术比较了过敏和不敏感的人根状牙本质的形态学特征。从同一根表面的不同区域采集过敏或不敏感的标本,在扫描电镜下观察。在分析之前,一些标本暴露于表面脱矿和消化胶原蛋白,以便观察牙本质小管的地下部分。在另一组观察中,光固化树脂衬垫在体外穿透根牙本质的潜力,并在治疗过敏根状牙本质后长期维持管状咬合。许多牙本质小管在高敏区是开放的,而非敏感区通常显示小管被矿化物质堵塞。hcl -胶原酶处理标本的扫描电镜图像显示,在过敏牙本质的小管中经常出现膜样结构。在非敏感牙本质中,这些结构稀疏。将光固化树脂衬垫局部应用于人拔牙根状牙本质中制备的楔形缺陷,可获得厚度为20-50微米的树脂涂层。树脂渗透到牙本质小管的深度超过5微米。用内胆治疗6个月后进行的牙本质活检显示,在大多数牙本质小管中存在树脂样物质,不再感觉到过敏。在所有的标本中,衬里都没有作为表面涂层保留下来。在复发性过敏的区域,超过一半的小管呈开孔。(摘要删节250字)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Morphological characterization of hypersensitive human radicular dentin and the effect of a light-curing resin liner on tubular occlusion.

A dentin biopsy technique was employed to compare the morphological features of hypersensitive and non-sensitive human radicular dentin. Specimens sampled from different areas in the same root surface displaying hypersensitivity or non-sensitivity were prepared for examination in the scanning electron microscope (SEM). Before analysis some specimens were exposed to surface demineralization and digestion of collagen to allow observation of subsurface portions of the dentinal tubules. In another set of observations the potential of a light-curing resin liner to penetrate root dentin in vitro and to maintain tubular occlusion over time following treatment of hypersensitive radicular dentin were examined. Orifices of many dentinal tubules were open in hypersensitive regions while non-sensitive areas generally displayed tubules occluded with mineralized material. SEM-images of HCl-collagenase treated specimens demonstrated the frequent presence of membrane-like structures in tubules of hypersensitive dentin. In non-sensitive dentin these structures were sparse. Topical application of a light-curing resin liner to wedge shaped defects prepared in radicular dentin of extracted human teeth resulted in a surface coating with a resin thickness of 20-50 microns. Resin penetrated dentinal tubules to a depth of more than 5 microns. Dentin biopsies examined 6 months after treatment with the liner showed presence of resin-like material in a majority of the tubules in dentin where hypersensitivity was no longer perceived. In none of the specimens did the liner remain as a surface coating. In areas of recurrent hypersensitivity more than half of the tubules presented with open orifices.(ABSTRACT TRUNCATED AT 250 WORDS)

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Function of masticatory system after surgical-orthodontic correction of maxillomandibular discrepancies. The Finnish Family Competence Study: young fathers' views on health education. Oral health status in a Finnish village. Trigeminal foraminal patterns in "skeletal" Class II and Class III adults--a radiocephalometric study. Comparison of dental arch dimensions in children from southern and northern Finland.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1