{"title":"有关国家变电站防雷系统设计的打击距离问题","authors":"S. C. Lim, Md Mahmudul Hasan, Ong Chang Shen","doi":"10.1109/APL57308.2023.10181684","DOIUrl":null,"url":null,"abstract":"Since the dawn of civilization, humans have been fascinated by one of the most common natural occurrences called lightning. It’s not just a fascinating but also dangerous occurrence for electrical equipment. Substation, which is one of the most important parts of power transmission and distribution, is susceptible to lightning strikes. If lightning directly strikes a substation, it may cause huge damage to the equipment of the substation. Thus, a proper lightning protection system is required in order to protect the substation. Striking distance is one of the most important aspects of a substation’s lightning protection design. This study aims to analyze the striking distance range for Japan, Austria, Brazil, Sweden and the USA based on methodologies and recorded lightning current found in the literature. The values of lightning peak current and types of lightning protection systems (mast/wire) are considered in the calculation of striking distance for the selected countries. Among the countries studied, the USA has the greatest striking distance range, while Sweden has the smallest. It is also observed that the striking distance range is significantly higher when the lightning mast is used instead of shield wire as lightning protection device. In addition, this paper presents a graphical representation of the recommended striking distance range for the selected countries which will help the designer to efficiently design the lightning protection system of substations for those selected countries.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On the Striking Distance for the Design of Lightning Protection System for Substations in Selected Countries\",\"authors\":\"S. C. Lim, Md Mahmudul Hasan, Ong Chang Shen\",\"doi\":\"10.1109/APL57308.2023.10181684\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Since the dawn of civilization, humans have been fascinated by one of the most common natural occurrences called lightning. It’s not just a fascinating but also dangerous occurrence for electrical equipment. Substation, which is one of the most important parts of power transmission and distribution, is susceptible to lightning strikes. If lightning directly strikes a substation, it may cause huge damage to the equipment of the substation. Thus, a proper lightning protection system is required in order to protect the substation. Striking distance is one of the most important aspects of a substation’s lightning protection design. This study aims to analyze the striking distance range for Japan, Austria, Brazil, Sweden and the USA based on methodologies and recorded lightning current found in the literature. The values of lightning peak current and types of lightning protection systems (mast/wire) are considered in the calculation of striking distance for the selected countries. Among the countries studied, the USA has the greatest striking distance range, while Sweden has the smallest. It is also observed that the striking distance range is significantly higher when the lightning mast is used instead of shield wire as lightning protection device. In addition, this paper presents a graphical representation of the recommended striking distance range for the selected countries which will help the designer to efficiently design the lightning protection system of substations for those selected countries.\",\"PeriodicalId\":371726,\"journal\":{\"name\":\"2023 12th Asia-Pacific International Conference on Lightning (APL)\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 12th Asia-Pacific International Conference on Lightning (APL)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APL57308.2023.10181684\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 12th Asia-Pacific International Conference on Lightning (APL)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APL57308.2023.10181684","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

自文明诞生以来,人类就被一种最常见的自然现象——闪电所吸引。对于电气设备来说,这不仅是一件令人着迷的事情,也是一件危险的事情。变电站是输配电系统的重要组成部分之一,易受雷击。如果雷击直接击中变电站,可能会对变电站的设备造成巨大的破坏。因此,需要适当的防雷系统来保护变电站。防雷距离是变电站防雷设计的重要内容之一。本研究旨在分析日本、奥地利、巴西、瑞典和美国的雷击距离范围,基于方法和文献中发现的记录雷击电流。在计算选定国家的雷击距离时,考虑了雷电峰值电流的值和避雷系统(桅杆/电线)的类型。在研究的国家中,美国的打击距离最大,而瑞典的打击距离最小。我们还观察到,当使用避雷桅杆代替屏蔽线作为避雷装置时,其打击距离范围明显更高。此外,本文还给出了所选国家的推荐打击距离范围的图形表示,以帮助设计人员有效地设计所选国家的变电站防雷系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
On the Striking Distance for the Design of Lightning Protection System for Substations in Selected Countries
Since the dawn of civilization, humans have been fascinated by one of the most common natural occurrences called lightning. It’s not just a fascinating but also dangerous occurrence for electrical equipment. Substation, which is one of the most important parts of power transmission and distribution, is susceptible to lightning strikes. If lightning directly strikes a substation, it may cause huge damage to the equipment of the substation. Thus, a proper lightning protection system is required in order to protect the substation. Striking distance is one of the most important aspects of a substation’s lightning protection design. This study aims to analyze the striking distance range for Japan, Austria, Brazil, Sweden and the USA based on methodologies and recorded lightning current found in the literature. The values of lightning peak current and types of lightning protection systems (mast/wire) are considered in the calculation of striking distance for the selected countries. Among the countries studied, the USA has the greatest striking distance range, while Sweden has the smallest. It is also observed that the striking distance range is significantly higher when the lightning mast is used instead of shield wire as lightning protection device. In addition, this paper presents a graphical representation of the recommended striking distance range for the selected countries which will help the designer to efficiently design the lightning protection system of substations for those selected countries.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of cost-effective lightning protection measures for underprivileged communities Preliminary Results of Corona Discharge Current Measurements in the Early Formation of Lightning on Tower Performance of Bentonite and Peat Moss Mixtures as Grounding Enhancement Materials Thunderstorm Prediction Model Using SMOTE Sampling and Machine Learning Approach A Year of Global Lightning Deaths and Injuries
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1