{"title":"分析用argento测定方法对排末(TPA) II Musi II Palembang周围的氯化井浓度的分析","authors":"M. Huljani, Nur Rahma","doi":"10.19109/alkimia.v2i2.2987","DOIUrl":null,"url":null,"abstract":"The community around Tempat Pembuangan Akhir (TPA) II Musi II Kelurahan Karya Jaya still relying on borehole water to fulfill their daily needs. The existence of TPA around these community environments can have a negative impact, including an indication of contamination of borehole water. One of the water pollution that is suspected to occur due to contamination of leachate from TPA is over chloride level in borehole water. The present work aimed at determining chloride level in borehole water in the area around Musi II TPA II Musi II Kelurahan Karya Jaya using Mohr argentometry titration method. The results showed chloride level in borehole water in the area around Musi II TPA II Musi II Kelurahan Karya Jaya is 301.75 mg/L. Based on PerMenKes RI No.492/MENKES/SK/VI/2010 and PerMenKes RI No.416/MENKES/ PER/IX/1990, the maximum level of chloride for drinking water is 250 mg/L, while for clean water is 600 mg/L, so that it can be concluded that borehole water in the area around Musi II TPA II Musi II Kelurahan Karya Jaya can’t be used for primary needs, for example drinking and cooking needs, but borehole water can still be used for secondary needs such as bathing and washing.","PeriodicalId":196624,"journal":{"name":"ALKIMIA : Jurnal Ilmu Kimia dan Terapan","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Analisis Kadar Klorida Air Sumur Bor Sekitar Tempat Pembuangan Akhir (TPA) II Musi II Palembang dengan Metode Titrasi Argentometri\",\"authors\":\"M. Huljani, Nur Rahma\",\"doi\":\"10.19109/alkimia.v2i2.2987\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The community around Tempat Pembuangan Akhir (TPA) II Musi II Kelurahan Karya Jaya still relying on borehole water to fulfill their daily needs. The existence of TPA around these community environments can have a negative impact, including an indication of contamination of borehole water. One of the water pollution that is suspected to occur due to contamination of leachate from TPA is over chloride level in borehole water. The present work aimed at determining chloride level in borehole water in the area around Musi II TPA II Musi II Kelurahan Karya Jaya using Mohr argentometry titration method. The results showed chloride level in borehole water in the area around Musi II TPA II Musi II Kelurahan Karya Jaya is 301.75 mg/L. Based on PerMenKes RI No.492/MENKES/SK/VI/2010 and PerMenKes RI No.416/MENKES/ PER/IX/1990, the maximum level of chloride for drinking water is 250 mg/L, while for clean water is 600 mg/L, so that it can be concluded that borehole water in the area around Musi II TPA II Musi II Kelurahan Karya Jaya can’t be used for primary needs, for example drinking and cooking needs, but borehole water can still be used for secondary needs such as bathing and washing.\",\"PeriodicalId\":196624,\"journal\":{\"name\":\"ALKIMIA : Jurnal Ilmu Kimia dan Terapan\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ALKIMIA : Jurnal Ilmu Kimia dan Terapan\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.19109/alkimia.v2i2.2987\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ALKIMIA : Jurnal Ilmu Kimia dan Terapan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19109/alkimia.v2i2.2987","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
摘要
temat Pembuangan Akhir (TPA) II Musi II Kelurahan Karya Jaya周围的社区仍然依靠钻孔水来满足他们的日常需求。在这些社区环境周围存在TPA可能会产生负面影响,包括表明钻孔水受到污染。被怀疑由TPA渗滤液污染引起的水污染之一是井水氯含量超标。本研究旨在利用莫尔滴定法测定Musi II TPA II Musi II Kelurahan Karya Jaya附近地区钻孔水中的氯化物含量。结果表明,Musi II TPA II Musi II Kelurahan Karya Jaya周边地区钻孔水中氯含量为301.75 mg/L。基于PerMenKes RI No.492 /门克斯/ SK / VI / 2010和PerMenKes RI No.416 /门克斯/ / / IX / 1990,最大程度的饮用水氯化是250 mg / L,而对于干净的水是600 mg / L,这样它就可以被认为井眼周围的水Musi II TPA II Musi II Kelurahan Karya Jaya不能用于基本需求,例如饮用和烹饪需求,但是仍然可以用于二次钻孔水需要洗澡和洗等。
Analisis Kadar Klorida Air Sumur Bor Sekitar Tempat Pembuangan Akhir (TPA) II Musi II Palembang dengan Metode Titrasi Argentometri
The community around Tempat Pembuangan Akhir (TPA) II Musi II Kelurahan Karya Jaya still relying on borehole water to fulfill their daily needs. The existence of TPA around these community environments can have a negative impact, including an indication of contamination of borehole water. One of the water pollution that is suspected to occur due to contamination of leachate from TPA is over chloride level in borehole water. The present work aimed at determining chloride level in borehole water in the area around Musi II TPA II Musi II Kelurahan Karya Jaya using Mohr argentometry titration method. The results showed chloride level in borehole water in the area around Musi II TPA II Musi II Kelurahan Karya Jaya is 301.75 mg/L. Based on PerMenKes RI No.492/MENKES/SK/VI/2010 and PerMenKes RI No.416/MENKES/ PER/IX/1990, the maximum level of chloride for drinking water is 250 mg/L, while for clean water is 600 mg/L, so that it can be concluded that borehole water in the area around Musi II TPA II Musi II Kelurahan Karya Jaya can’t be used for primary needs, for example drinking and cooking needs, but borehole water can still be used for secondary needs such as bathing and washing.