基于空间频率分布的体表心房信号分析:不同信号变换的比较

Olivier Meste, S. Zeemering, Joël M. H. Karel, T. Lankveld, U. Schotten, H. Crijns, R. Peeters, P. Bonizzi
{"title":"基于空间频率分布的体表心房信号分析:不同信号变换的比较","authors":"Olivier Meste, S. Zeemering, Joël M. H. Karel, T. Lankveld, U. Schotten, H. Crijns, R. Peeters, P. Bonizzi","doi":"10.23919/cinc53138.2021.9662947","DOIUrl":null,"url":null,"abstract":"In contrast to electrograms, Body-Surface Potential Mapping (BSPM) records the global atrial activity, at the expenses of a lower spatial accuracy. The aim of this study is to investigate whether BSPM recordings can discriminate persistent patients undergoing electrical cardiover-sion, based on the body-surface normalized AF spatial frequency distribution. High-density BSPMs (120 anterior, 64 posterior electrodes) were recorded in 63 patients with persistent AF. For each patient and electrode recording, the frequency content of AF was analyzed on the raw signal, and also by means of the normalized correlation function, and by Singular Spectrum Analysis (SSA). In order to compare the body-surface spatial distributions of AF frequency in all patients, these distributions were first normalized, before performing statistical analysis. We found that the distribution of AF frequency on the body-surface, and its interpretation, are strongly dependent on the specific method employed. Moreover, the estimated body-surface AF frequency was greater over the central posterior and the right anterior BSPM locations. Finally, SSA-based decomposition followed by frequency analysis could discriminate AF patients recurring 4 to 6 weeks after electrical cardioversion from those who did not, based on the frequency content in the proximity of V1.","PeriodicalId":126746,"journal":{"name":"2021 Computing in Cardiology (CinC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Body-Surface Atrial Signals Analysis Based on Spatial Frequency Distribution: Comparison Between Different Signal Transformations\",\"authors\":\"Olivier Meste, S. Zeemering, Joël M. H. Karel, T. Lankveld, U. Schotten, H. Crijns, R. Peeters, P. Bonizzi\",\"doi\":\"10.23919/cinc53138.2021.9662947\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In contrast to electrograms, Body-Surface Potential Mapping (BSPM) records the global atrial activity, at the expenses of a lower spatial accuracy. The aim of this study is to investigate whether BSPM recordings can discriminate persistent patients undergoing electrical cardiover-sion, based on the body-surface normalized AF spatial frequency distribution. High-density BSPMs (120 anterior, 64 posterior electrodes) were recorded in 63 patients with persistent AF. For each patient and electrode recording, the frequency content of AF was analyzed on the raw signal, and also by means of the normalized correlation function, and by Singular Spectrum Analysis (SSA). In order to compare the body-surface spatial distributions of AF frequency in all patients, these distributions were first normalized, before performing statistical analysis. We found that the distribution of AF frequency on the body-surface, and its interpretation, are strongly dependent on the specific method employed. Moreover, the estimated body-surface AF frequency was greater over the central posterior and the right anterior BSPM locations. Finally, SSA-based decomposition followed by frequency analysis could discriminate AF patients recurring 4 to 6 weeks after electrical cardioversion from those who did not, based on the frequency content in the proximity of V1.\",\"PeriodicalId\":126746,\"journal\":{\"name\":\"2021 Computing in Cardiology (CinC)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 Computing in Cardiology (CinC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/cinc53138.2021.9662947\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Computing in Cardiology (CinC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/cinc53138.2021.9662947","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

与电图相比,体表电位映射(BSPM)记录了整体心房活动,以较低的空间精度为代价。本研究的目的是基于体表归一化心房颤动的空间频率分布,探讨BSPM记录是否可以区分持续性心电性心律失常患者。记录63例持续性房颤患者的高密度BSPMs(120个前电极,64个后电极)。对每个患者和电极记录的房颤频率内容进行原始信号分析,并通过归一化相关函数和奇异谱分析(SSA)进行分析。为了比较所有患者AF频率的体表空间分布,首先将这些分布归一化,然后进行统计分析。我们发现AF频率在体表上的分布及其解释强烈依赖于所采用的具体方法。此外,估计的体表AF频率在BSPM中央后位和右前位更高。最后,基于ssa的分解和频率分析可以根据V1附近的频率内容区分电转复后4至6周复发的AF患者和未复发的AF患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Body-Surface Atrial Signals Analysis Based on Spatial Frequency Distribution: Comparison Between Different Signal Transformations
In contrast to electrograms, Body-Surface Potential Mapping (BSPM) records the global atrial activity, at the expenses of a lower spatial accuracy. The aim of this study is to investigate whether BSPM recordings can discriminate persistent patients undergoing electrical cardiover-sion, based on the body-surface normalized AF spatial frequency distribution. High-density BSPMs (120 anterior, 64 posterior electrodes) were recorded in 63 patients with persistent AF. For each patient and electrode recording, the frequency content of AF was analyzed on the raw signal, and also by means of the normalized correlation function, and by Singular Spectrum Analysis (SSA). In order to compare the body-surface spatial distributions of AF frequency in all patients, these distributions were first normalized, before performing statistical analysis. We found that the distribution of AF frequency on the body-surface, and its interpretation, are strongly dependent on the specific method employed. Moreover, the estimated body-surface AF frequency was greater over the central posterior and the right anterior BSPM locations. Finally, SSA-based decomposition followed by frequency analysis could discriminate AF patients recurring 4 to 6 weeks after electrical cardioversion from those who did not, based on the frequency content in the proximity of V1.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Influence of Hydroxychloroquine Dosage on the Occurrence of Arrhythmia in COVID-19 Infected Ventricle Guinea Pig ECG Changes under the Effect of New Drug Candidate TP28b Electrocardiographic Imaging of Sinus Rhythm in Pig Hearts Using Bayesian Maximum A Posteriori Estimation Sensitivity Analysis and Parameter Identification of a Cardiovascular Model in Aortic Stenosis Semi-Supervised vs. Supervised Learning for Discriminating Atrial Flutter Mechanisms Using the 12-lead ECG
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1