{"title":"心血管对集中应用氯化钠溶液的反应。","authors":"A Brattström, E Appenrodt, A Brattström, L Pharow","doi":"10.3109/10641969209038192","DOIUrl":null,"url":null,"abstract":"<p><p>In conscious and anaesthetized rats the baroreceptor heart reflex (BHR) was checked before and after i.c.v. application of isotonic or hypertonic (0.6 M; 1.0 M) NaCl solution, artificial cerebrospinal fluid (aCSF) and 1.0 M mannitol solution. The BHR was tested by evaluating the alteration of the inter-beat interval (IBI) in response to an artificial BP rise or drop which had been evoked by i.v. bolus injection of either phenylephrine or sodium nitroprusside. The slope of the correlation function was taken to index the reflex sensitivity. In anaesthetized rats the mean sensitivity of the BHR was 0.6 ms/mm Hg (phenylephrine). l.c.v. administration of isotonic NaCl solution did not change BP, IBI or the BHR sensitivity, whilst i.c.v. infusion of hypertonic NaCl solution increased BP and shortened IBI. The BHR sensitivity was impaired only when 1.0 M NaCl solution was i.c.v. infused by 0.23 ms/mm Hg. In conscious rats the mean sensitivity of the BHR was 1.14 ms/mm Hg (phenylephrine) and 1.35 ms/mm Hg (sodium nitroprusside). In the conscious rats i.c.v. bolus injection of hypertonic NaCl solution increased BP as in anaesthetized rats, however, the IBI was prolonged, whilst 1.0 M mannitol solution and aCSF were without any influence on BP, IBI and BHR. l.c.v. administration of hypertonic NaCl solution reduced the BHR sensitivity by approximately 0.6 ms/mm Hg.</p>","PeriodicalId":10339,"journal":{"name":"Clinical and experimental hypertension. Part A, Theory and practice","volume":"14 6","pages":"1051-65"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10641969209038192","citationCount":"3","resultStr":"{\"title\":\"Cardiovascular responses to centrally applied sodium chloride solution.\",\"authors\":\"A Brattström, E Appenrodt, A Brattström, L Pharow\",\"doi\":\"10.3109/10641969209038192\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In conscious and anaesthetized rats the baroreceptor heart reflex (BHR) was checked before and after i.c.v. application of isotonic or hypertonic (0.6 M; 1.0 M) NaCl solution, artificial cerebrospinal fluid (aCSF) and 1.0 M mannitol solution. The BHR was tested by evaluating the alteration of the inter-beat interval (IBI) in response to an artificial BP rise or drop which had been evoked by i.v. bolus injection of either phenylephrine or sodium nitroprusside. The slope of the correlation function was taken to index the reflex sensitivity. In anaesthetized rats the mean sensitivity of the BHR was 0.6 ms/mm Hg (phenylephrine). l.c.v. administration of isotonic NaCl solution did not change BP, IBI or the BHR sensitivity, whilst i.c.v. infusion of hypertonic NaCl solution increased BP and shortened IBI. The BHR sensitivity was impaired only when 1.0 M NaCl solution was i.c.v. infused by 0.23 ms/mm Hg. In conscious rats the mean sensitivity of the BHR was 1.14 ms/mm Hg (phenylephrine) and 1.35 ms/mm Hg (sodium nitroprusside). In the conscious rats i.c.v. bolus injection of hypertonic NaCl solution increased BP as in anaesthetized rats, however, the IBI was prolonged, whilst 1.0 M mannitol solution and aCSF were without any influence on BP, IBI and BHR. l.c.v. administration of hypertonic NaCl solution reduced the BHR sensitivity by approximately 0.6 ms/mm Hg.</p>\",\"PeriodicalId\":10339,\"journal\":{\"name\":\"Clinical and experimental hypertension. Part A, Theory and practice\",\"volume\":\"14 6\",\"pages\":\"1051-65\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10641969209038192\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical and experimental hypertension. Part A, Theory and practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10641969209038192\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and experimental hypertension. Part A, Theory and practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10641969209038192","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
摘要
清醒大鼠和麻醉大鼠分别用等渗或高渗(0.6 M;1.0 M) NaCl溶液,人工脑脊液(aCSF)和1.0 M甘露醇溶液。BHR是通过静脉注射苯肾上腺素或硝普钠引起的人工血压升高或下降对搏动间期(IBI)的影响来检测的。用相关函数的斜率来表示反射灵敏度。麻醉大鼠BHR平均敏感性为0.6 ms/mm Hg(苯肾上腺素)。等渗NaCl对血压、IBI及BHR敏感性无明显影响,而高渗NaCl使血压升高,IBI缩短。仅当1.0 M NaCl溶液中注入0.23 ms/mm Hg时,BHR的敏感性受损,清醒大鼠BHR的平均敏感性为1.14 ms/mm Hg(苯肾上腺素)和1.35 ms/mm Hg(硝普钠)。在清醒大鼠中,大量注射高渗NaCl溶液使血压升高,但与麻醉大鼠相比,IBI延长,而1.0 M甘露醇溶液和aCSF对BP、IBI和BHR无影响。高渗NaCl溶液使BHR敏感性降低约0.6 ms/mm Hg。
Cardiovascular responses to centrally applied sodium chloride solution.
In conscious and anaesthetized rats the baroreceptor heart reflex (BHR) was checked before and after i.c.v. application of isotonic or hypertonic (0.6 M; 1.0 M) NaCl solution, artificial cerebrospinal fluid (aCSF) and 1.0 M mannitol solution. The BHR was tested by evaluating the alteration of the inter-beat interval (IBI) in response to an artificial BP rise or drop which had been evoked by i.v. bolus injection of either phenylephrine or sodium nitroprusside. The slope of the correlation function was taken to index the reflex sensitivity. In anaesthetized rats the mean sensitivity of the BHR was 0.6 ms/mm Hg (phenylephrine). l.c.v. administration of isotonic NaCl solution did not change BP, IBI or the BHR sensitivity, whilst i.c.v. infusion of hypertonic NaCl solution increased BP and shortened IBI. The BHR sensitivity was impaired only when 1.0 M NaCl solution was i.c.v. infused by 0.23 ms/mm Hg. In conscious rats the mean sensitivity of the BHR was 1.14 ms/mm Hg (phenylephrine) and 1.35 ms/mm Hg (sodium nitroprusside). In the conscious rats i.c.v. bolus injection of hypertonic NaCl solution increased BP as in anaesthetized rats, however, the IBI was prolonged, whilst 1.0 M mannitol solution and aCSF were without any influence on BP, IBI and BHR. l.c.v. administration of hypertonic NaCl solution reduced the BHR sensitivity by approximately 0.6 ms/mm Hg.