M. Bajger, Fei Ma, M. Bottema
{"title":"用于配准和质量检测算法的乳房x光片MST分割的自动调整","authors":"M. Bajger, Fei Ma, M. Bottema","doi":"10.1109/DICTA.2009.72","DOIUrl":null,"url":null,"abstract":"A technique utilizing an entropy measure is developed for automatically tuning the segmentation of screening mammograms by minimum spanning trees (MST). The lack of such technique has been a major obstacle in previous work to segment mammograms for registration and applying mass detection algorithms. The proposed method is tested on two sets of mammograms: a set of 55 mammograms chosen from a publicly available Mini-MIAS database, and a set of 37 mammograms selected from a local database. The method performance is evaluated in conjunction with three different preprocessing filters: gaussian, anisotropic and neutrosophic. Results show that the automatic tuning has the potential to produce state-of-the art segmentation of mass-like objects in mammograms. The neutrosophic filtering provided the best performance.","PeriodicalId":277395,"journal":{"name":"2009 Digital Image Computing: Techniques and Applications","volume":"73 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Automatic Tuning of MST Segmentation of Mammograms for Registration and Mass Detection Algorithms\",\"authors\":\"M. Bajger, Fei Ma, M. Bottema\",\"doi\":\"10.1109/DICTA.2009.72\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A technique utilizing an entropy measure is developed for automatically tuning the segmentation of screening mammograms by minimum spanning trees (MST). The lack of such technique has been a major obstacle in previous work to segment mammograms for registration and applying mass detection algorithms. The proposed method is tested on two sets of mammograms: a set of 55 mammograms chosen from a publicly available Mini-MIAS database, and a set of 37 mammograms selected from a local database. The method performance is evaluated in conjunction with three different preprocessing filters: gaussian, anisotropic and neutrosophic. Results show that the automatic tuning has the potential to produce state-of-the art segmentation of mass-like objects in mammograms. The neutrosophic filtering provided the best performance.\",\"PeriodicalId\":277395,\"journal\":{\"name\":\"2009 Digital Image Computing: Techniques and Applications\",\"volume\":\"73 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Digital Image Computing: Techniques and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DICTA.2009.72\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Digital Image Computing: Techniques and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DICTA.2009.72","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

提出了一种利用熵测度的方法,利用最小生成树(MST)自动调整乳房x线影像的分割。缺乏这样的技术一直是一个主要障碍,在以前的工作中,分割乳房x线照片登记和应用质量检测算法。所提出的方法在两组乳房x光片上进行了测试:一组从公开可用的Mini-MIAS数据库中选择的55张乳房x光片,以及从本地数据库中选择的37张乳房x光片。结合三种不同的预处理滤波器:高斯滤波器、各向异性滤波器和中性滤波器,对该方法的性能进行了评估。结果表明,自动调谐有可能在乳房x光片中产生最先进的肿块样物体分割。中性粒细胞过滤效果最好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Automatic Tuning of MST Segmentation of Mammograms for Registration and Mass Detection Algorithms
A technique utilizing an entropy measure is developed for automatically tuning the segmentation of screening mammograms by minimum spanning trees (MST). The lack of such technique has been a major obstacle in previous work to segment mammograms for registration and applying mass detection algorithms. The proposed method is tested on two sets of mammograms: a set of 55 mammograms chosen from a publicly available Mini-MIAS database, and a set of 37 mammograms selected from a local database. The method performance is evaluated in conjunction with three different preprocessing filters: gaussian, anisotropic and neutrosophic. Results show that the automatic tuning has the potential to produce state-of-the art segmentation of mass-like objects in mammograms. The neutrosophic filtering provided the best performance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Video Surveillance: Legally Blind? Mixed Pixel Analysis for Flood Mapping Using Extended Support Vector Machine 3D Reconstruction of Patient Specific Bone Models from 2D Radiographs for Image Guided Orthopedic Surgery Improved Single Image Dehazing Using Geometry Crowd Counting Using Multiple Local Features
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1