{"title":"三相高输出感应功率传输中的无功补偿","authors":"A. Safaee, K. Woronowicz, Tim R. Dickson","doi":"10.1109/EPEC.2015.7379979","DOIUrl":null,"url":null,"abstract":"Inductive power transfer becomes increasingly more popular as a method for contact less charging of high power loads. Enabled by the rapid progress in power electronics components and controls, the power transfer solutions cross the previously unattainable boundaries of power levels and cost limits. Because of the high frequencies necessary for voltage induction in the secondary parts of the transformers and because of a rather low magnetic coupling, the system would have to constantly supply high levels of the reactive power, generating very high losses and limiting the available output power. Various tuning techniques have developed to tune-out the reactive power. In this paper a systematic approach to tuning of a high power three phase coupled transformer is presented and arithmetical calculations backed by simulation utilizing its values from the electromagnetic FEA analysis. The approach is based on the fundamental frequency approximation neglecting the higher order harmonics which is valid for tuning the system at the fundamental harmonics of the switching frequency.","PeriodicalId":231255,"journal":{"name":"2015 IEEE Electrical Power and Energy Conference (EPEC)","volume":"78 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Reactive power compensation in three phase high output inductive power transfer\",\"authors\":\"A. Safaee, K. Woronowicz, Tim R. Dickson\",\"doi\":\"10.1109/EPEC.2015.7379979\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Inductive power transfer becomes increasingly more popular as a method for contact less charging of high power loads. Enabled by the rapid progress in power electronics components and controls, the power transfer solutions cross the previously unattainable boundaries of power levels and cost limits. Because of the high frequencies necessary for voltage induction in the secondary parts of the transformers and because of a rather low magnetic coupling, the system would have to constantly supply high levels of the reactive power, generating very high losses and limiting the available output power. Various tuning techniques have developed to tune-out the reactive power. In this paper a systematic approach to tuning of a high power three phase coupled transformer is presented and arithmetical calculations backed by simulation utilizing its values from the electromagnetic FEA analysis. The approach is based on the fundamental frequency approximation neglecting the higher order harmonics which is valid for tuning the system at the fundamental harmonics of the switching frequency.\",\"PeriodicalId\":231255,\"journal\":{\"name\":\"2015 IEEE Electrical Power and Energy Conference (EPEC)\",\"volume\":\"78 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Electrical Power and Energy Conference (EPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPEC.2015.7379979\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Electrical Power and Energy Conference (EPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEC.2015.7379979","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

感应功率传输作为一种高功率负载的无接触充电方法越来越受到人们的欢迎。由于电力电子元件和控制的快速发展,电力传输解决方案跨越了以前无法实现的功率水平和成本限制。由于变压器二次部分的电压感应所需的高频和相当低的磁耦合,系统将不得不不断地提供高水平的无功功率,产生非常高的损耗并限制可用的输出功率。各种各样的调谐技术已经发展出来以调谐无功功率。本文提出了一种大功率三相耦合变压器的系统调谐方法,并利用电磁有限元分析的数值进行了仿真计算。该方法基于基频近似,忽略高次谐波,可以在开关频率的基频处对系统进行调谐。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reactive power compensation in three phase high output inductive power transfer
Inductive power transfer becomes increasingly more popular as a method for contact less charging of high power loads. Enabled by the rapid progress in power electronics components and controls, the power transfer solutions cross the previously unattainable boundaries of power levels and cost limits. Because of the high frequencies necessary for voltage induction in the secondary parts of the transformers and because of a rather low magnetic coupling, the system would have to constantly supply high levels of the reactive power, generating very high losses and limiting the available output power. Various tuning techniques have developed to tune-out the reactive power. In this paper a systematic approach to tuning of a high power three phase coupled transformer is presented and arithmetical calculations backed by simulation utilizing its values from the electromagnetic FEA analysis. The approach is based on the fundamental frequency approximation neglecting the higher order harmonics which is valid for tuning the system at the fundamental harmonics of the switching frequency.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison between numerical and analytical methods of AC resistance evaluation for Medium Frequency Transformers: Validation on a prototype Improved control strategy of full-bridge modular multilevel converter Appliance scheduling optimization in smart home networks comprising of smart appliances and a photovoltaic panel Dynamic Reactive Power Compensation for voltage support using Static VAR Compensator (SVC) In Saudi Arabia Observability analysis of power systems in the presence of hybrid measurements
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1