建筑物中组合梁的最小剪切连接度

E. Aggelopoulos, G. Couchman, M. Lawson
{"title":"建筑物中组合梁的最小剪切连接度","authors":"E. Aggelopoulos, G. Couchman, M. Lawson","doi":"10.4995/ASCCS2018.2018.7127","DOIUrl":null,"url":null,"abstract":"Composite floors are often used in building construction where beams typically span from 6 to 18 m. They are commonly used together with decking of 50 to 80 mm depth that spans 3 to 4.5 m between the beams. Rules for the minimum degree of shear connection in composite beams are presented in Eurocode 4 and other international Codes, and were derived for beams in propped construction.Eurocode 4 defines a minimum limit for the degree of shear connection, primarily to ensure that slip at the steel-concrete interface does not exceed a limiting value. This limit is proportionate to the beam span and also depends on the steel strength and the asymmetry of the flange areas of the section. Currently, many designs cannot achieve the codified degree of shear connection demands, since it is not possible to accommodate a sufficient number of shear connectors on the span as dictated by the spacing of the deck ribs. However, there are special cases which are not explicitly accounted for in Codes. This paper aims to investigate the degree of shear connection requirements in such cases, including beams that are unpropped in construction, beams that are not fully utilised in bending because serviceability criteria govern their design and beams that are predominantly loaded by point loads rather than uniform loading.The results from parametric finite element analyses carried out using ANSYS for beams in the span range of 6 to 18 m are presented. The finite element models have been calibrated against composite beam tests. Comparisons are made with the current Eurocode 4 provisions and modifications are proposed where appropriate.","PeriodicalId":320267,"journal":{"name":"Proceedings 12th international conference on Advances in Steel-Concrete Composite Structures - ASCCS 2018","volume":"15 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Minimum degree of shear connection in composite beams in buildings\",\"authors\":\"E. Aggelopoulos, G. Couchman, M. Lawson\",\"doi\":\"10.4995/ASCCS2018.2018.7127\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Composite floors are often used in building construction where beams typically span from 6 to 18 m. They are commonly used together with decking of 50 to 80 mm depth that spans 3 to 4.5 m between the beams. Rules for the minimum degree of shear connection in composite beams are presented in Eurocode 4 and other international Codes, and were derived for beams in propped construction.Eurocode 4 defines a minimum limit for the degree of shear connection, primarily to ensure that slip at the steel-concrete interface does not exceed a limiting value. This limit is proportionate to the beam span and also depends on the steel strength and the asymmetry of the flange areas of the section. Currently, many designs cannot achieve the codified degree of shear connection demands, since it is not possible to accommodate a sufficient number of shear connectors on the span as dictated by the spacing of the deck ribs. However, there are special cases which are not explicitly accounted for in Codes. This paper aims to investigate the degree of shear connection requirements in such cases, including beams that are unpropped in construction, beams that are not fully utilised in bending because serviceability criteria govern their design and beams that are predominantly loaded by point loads rather than uniform loading.The results from parametric finite element analyses carried out using ANSYS for beams in the span range of 6 to 18 m are presented. The finite element models have been calibrated against composite beam tests. Comparisons are made with the current Eurocode 4 provisions and modifications are proposed where appropriate.\",\"PeriodicalId\":320267,\"journal\":{\"name\":\"Proceedings 12th international conference on Advances in Steel-Concrete Composite Structures - ASCCS 2018\",\"volume\":\"15 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-03-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings 12th international conference on Advances in Steel-Concrete Composite Structures - ASCCS 2018\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4995/ASCCS2018.2018.7127\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings 12th international conference on Advances in Steel-Concrete Composite Structures - ASCCS 2018","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4995/ASCCS2018.2018.7127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

复合地板通常用于梁跨度通常为6至18米的建筑施工中。它们通常与50至80毫米深的甲板一起使用,横梁之间的跨度为3至4.5米。欧洲规范4和其他国际规范中提出了组合梁的最小剪切连接度规则,并推导了支撑结构梁的规则。欧洲规范4规定了剪切连接程度的最小限值,主要是为了确保钢-混凝土界面的滑移不超过限值。这一限制是成比例的梁跨度,也取决于钢的强度和截面的法兰区域的不对称。目前,许多设计无法达到规范的剪切连接要求,因为根据甲板肋间距的规定,不可能在跨度上容纳足够数量的剪切连接。但是,有些特殊情况在守则中没有明确说明。本文旨在研究在这种情况下剪切连接要求的程度,包括在施工中没有支撑的梁,由于使用标准控制其设计而没有充分利用弯曲的梁,以及主要由点荷载而不是均匀荷载加载的梁。给出了用ANSYS对跨度为6 ~ 18 m的梁进行参数化有限元分析的结果。根据复合梁试验对有限元模型进行了校正。与现行的欧洲法规4条款进行比较,并在适当的情况下提出修改建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Minimum degree of shear connection in composite beams in buildings
Composite floors are often used in building construction where beams typically span from 6 to 18 m. They are commonly used together with decking of 50 to 80 mm depth that spans 3 to 4.5 m between the beams. Rules for the minimum degree of shear connection in composite beams are presented in Eurocode 4 and other international Codes, and were derived for beams in propped construction.Eurocode 4 defines a minimum limit for the degree of shear connection, primarily to ensure that slip at the steel-concrete interface does not exceed a limiting value. This limit is proportionate to the beam span and also depends on the steel strength and the asymmetry of the flange areas of the section. Currently, many designs cannot achieve the codified degree of shear connection demands, since it is not possible to accommodate a sufficient number of shear connectors on the span as dictated by the spacing of the deck ribs. However, there are special cases which are not explicitly accounted for in Codes. This paper aims to investigate the degree of shear connection requirements in such cases, including beams that are unpropped in construction, beams that are not fully utilised in bending because serviceability criteria govern their design and beams that are predominantly loaded by point loads rather than uniform loading.The results from parametric finite element analyses carried out using ANSYS for beams in the span range of 6 to 18 m are presented. The finite element models have been calibrated against composite beam tests. Comparisons are made with the current Eurocode 4 provisions and modifications are proposed where appropriate.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A novel one-sided push-out test for shear connectors in composite beams Bending Moment Capacity of Stainless Steel-Concrete Composite Beams COMPARISON OF DESIGN FOR COMPOSITE COLUMNS IN STEEL AND CONCRETE ACCORDING TO EUROCODE 4 AND CHINESE DESIGN CODES An innovative concrete-steel structural system allowing for a fast and simple erection Influence of joint rigidity on the elastic buckling load of sway and non-sway steel frames
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1