无线胶囊内窥镜超声(WCEU)

J. H. Lee, G. Traverso, Carl M. Schoellhammer, D. Blankschtein, R. Langer, K. Thomenius, D. Boning, B. Anthony
{"title":"无线胶囊内窥镜超声(WCEU)","authors":"J. H. Lee, G. Traverso, Carl M. Schoellhammer, D. Blankschtein, R. Langer, K. Thomenius, D. Boning, B. Anthony","doi":"10.1109/ULTSYM.2014.0181","DOIUrl":null,"url":null,"abstract":"Wireless capsule endoscopy (WCE) has revolutionized the capacity for evaluation of the gastrointestinal (GI) tract. Although WCE provides high quality images of the GI tract, evaluation is limited to the mucosal surface. This work investigates feasibility and design considerations for wireless capsule endoscopic ultrasound (WCEU) that combines the benefits of WCE and ultrasound imaging. This work has two goals: (1) evaluate transducer designs appropriate for WCEU and (2) investigate whether peristalsis can produce sufficient contact to ensure acoustic coupling. Between mechanical scanning (MS) and side-looking array (SLA) designs, MS performs better for both imaging performance and system complexity. In vivo imaging in pigs demonstrates promising results, although the effect of peristalsis and resulting coverage needs further investigation and quantification.","PeriodicalId":153901,"journal":{"name":"2014 IEEE International Ultrasonics Symposium","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":"{\"title\":\"Towards wireless capsule endoscopic ultrasound (WCEU)\",\"authors\":\"J. H. Lee, G. Traverso, Carl M. Schoellhammer, D. Blankschtein, R. Langer, K. Thomenius, D. Boning, B. Anthony\",\"doi\":\"10.1109/ULTSYM.2014.0181\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Wireless capsule endoscopy (WCE) has revolutionized the capacity for evaluation of the gastrointestinal (GI) tract. Although WCE provides high quality images of the GI tract, evaluation is limited to the mucosal surface. This work investigates feasibility and design considerations for wireless capsule endoscopic ultrasound (WCEU) that combines the benefits of WCE and ultrasound imaging. This work has two goals: (1) evaluate transducer designs appropriate for WCEU and (2) investigate whether peristalsis can produce sufficient contact to ensure acoustic coupling. Between mechanical scanning (MS) and side-looking array (SLA) designs, MS performs better for both imaging performance and system complexity. In vivo imaging in pigs demonstrates promising results, although the effect of peristalsis and resulting coverage needs further investigation and quantification.\",\"PeriodicalId\":153901,\"journal\":{\"name\":\"2014 IEEE International Ultrasonics Symposium\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE International Ultrasonics Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.2014.0181\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE International Ultrasonics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2014.0181","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

摘要

无线胶囊内窥镜(WCE)已经彻底改变了评估胃肠道(GI)的能力。虽然WCE提供了高质量的胃肠道图像,但评估仅限于粘膜表面。这项工作探讨了无线胶囊内窥镜超声(WCEU)的可行性和设计考虑,它结合了WCE和超声成像的优点。这项工作有两个目标:(1)评估适合WCEU的换能器设计;(2)研究振动是否能产生足够的接触以确保声学耦合。在机械扫描(MS)和侧视阵列(SLA)设计之间,MS在成像性能和系统复杂性方面都表现得更好。猪体内成像显示了有希望的结果,尽管蠕动的影响和由此产生的覆盖范围需要进一步的调查和量化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Towards wireless capsule endoscopic ultrasound (WCEU)
Wireless capsule endoscopy (WCE) has revolutionized the capacity for evaluation of the gastrointestinal (GI) tract. Although WCE provides high quality images of the GI tract, evaluation is limited to the mucosal surface. This work investigates feasibility and design considerations for wireless capsule endoscopic ultrasound (WCEU) that combines the benefits of WCE and ultrasound imaging. This work has two goals: (1) evaluate transducer designs appropriate for WCEU and (2) investigate whether peristalsis can produce sufficient contact to ensure acoustic coupling. Between mechanical scanning (MS) and side-looking array (SLA) designs, MS performs better for both imaging performance and system complexity. In vivo imaging in pigs demonstrates promising results, although the effect of peristalsis and resulting coverage needs further investigation and quantification.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Carotid plaque assessment using non-invasive shear strain elastography Elastic modulus contrast enhancement in shear wave imaging using mechanical nonlinearity: In vitro tissue mimicking phantom study Tumor perfusion and neovascular morphology measurements using dynamic contrast-enhanced ultrasound imaging Application of a rigorous nonlinear P-matrix method to the simulation of third order intermodulation in test devices and duplexers Adaptive beamforming for thermal strain imaging using a single ultrasound linear array
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1