{"title":"[用Cardio 200计算机评价左室壁动力学]。","authors":"A Vosecková, H Weisbauerová, J Sístek","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The WALLMO program was used in comparing normal kinetic values of left ventricle wall with those obtained from control patients and literature sources. Authors concluded that, when based on the original data for RAO projection, the evaluation of regional LV wall contractility gives erroneous results in estimating whether a given section is normo- hypo- or hyperkinetic. Therefore, the set of normal kinetic values of LV motion has been formed for individual numbers of radials. This set may be used also at other working sites.</p>","PeriodicalId":76515,"journal":{"name":"Sbornik vedeckych praci Lekarske fakulty Karlovy univerzity v Hradci Kralove. Supplementum","volume":"35 1","pages":"81-8"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Evaluation of the kinetics of the left ventricular wall using the Cardio 200 computer].\",\"authors\":\"A Vosecková, H Weisbauerová, J Sístek\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The WALLMO program was used in comparing normal kinetic values of left ventricle wall with those obtained from control patients and literature sources. Authors concluded that, when based on the original data for RAO projection, the evaluation of regional LV wall contractility gives erroneous results in estimating whether a given section is normo- hypo- or hyperkinetic. Therefore, the set of normal kinetic values of LV motion has been formed for individual numbers of radials. This set may be used also at other working sites.</p>\",\"PeriodicalId\":76515,\"journal\":{\"name\":\"Sbornik vedeckych praci Lekarske fakulty Karlovy univerzity v Hradci Kralove. Supplementum\",\"volume\":\"35 1\",\"pages\":\"81-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sbornik vedeckych praci Lekarske fakulty Karlovy univerzity v Hradci Kralove. Supplementum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sbornik vedeckych praci Lekarske fakulty Karlovy univerzity v Hradci Kralove. Supplementum","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Evaluation of the kinetics of the left ventricular wall using the Cardio 200 computer].
The WALLMO program was used in comparing normal kinetic values of left ventricle wall with those obtained from control patients and literature sources. Authors concluded that, when based on the original data for RAO projection, the evaluation of regional LV wall contractility gives erroneous results in estimating whether a given section is normo- hypo- or hyperkinetic. Therefore, the set of normal kinetic values of LV motion has been formed for individual numbers of radials. This set may be used also at other working sites.