配电网承载能力:分布式发电导致的网络拥塞风险评估

M. Rossi, G. Vigano, D. Moneta
{"title":"配电网承载能力:分布式发电导致的网络拥塞风险评估","authors":"M. Rossi, G. Vigano, D. Moneta","doi":"10.1109/ICCEP.2015.7177570","DOIUrl":null,"url":null,"abstract":"The integration of generation units in distribution grids is one of the main research topics in the field of smart grids. Governments are supporting the connection of small/medium size generators directly to the distribution network, but the consequent growing number of energy producers poses several technical issues. For the planning and operation of a distribution network it is then important to estimate the maximum installable generation according to the limits imposed by the power quality standards. In the recent years, several methods for the evaluation of the Hosting Capacity (HC) has been proposed and designed in order to take into account different aspects related to the reliable operation of the network. However, many methods are not taking into account the effects of the grid allocation of distributed generation and, especially, the unknown position of it before the power plants realization. The paper describes a novel solution to compute the HC on the basis of the risk of network congestion. In addition to the classical voltage and current constraints, the proposed approach also integrates the stochastic allocation of distributed generation and separately evaluates their impact on the HC value.","PeriodicalId":423870,"journal":{"name":"2015 International Conference on Clean Electrical Power (ICCEP)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"26","resultStr":"{\"title\":\"Hosting capacity of distribution networks: Evaluation of the network congestion risk due to distributed generation\",\"authors\":\"M. Rossi, G. Vigano, D. Moneta\",\"doi\":\"10.1109/ICCEP.2015.7177570\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The integration of generation units in distribution grids is one of the main research topics in the field of smart grids. Governments are supporting the connection of small/medium size generators directly to the distribution network, but the consequent growing number of energy producers poses several technical issues. For the planning and operation of a distribution network it is then important to estimate the maximum installable generation according to the limits imposed by the power quality standards. In the recent years, several methods for the evaluation of the Hosting Capacity (HC) has been proposed and designed in order to take into account different aspects related to the reliable operation of the network. However, many methods are not taking into account the effects of the grid allocation of distributed generation and, especially, the unknown position of it before the power plants realization. The paper describes a novel solution to compute the HC on the basis of the risk of network congestion. In addition to the classical voltage and current constraints, the proposed approach also integrates the stochastic allocation of distributed generation and separately evaluates their impact on the HC value.\",\"PeriodicalId\":423870,\"journal\":{\"name\":\"2015 International Conference on Clean Electrical Power (ICCEP)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"26\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Clean Electrical Power (ICCEP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCEP.2015.7177570\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Clean Electrical Power (ICCEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCEP.2015.7177570","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

摘要

配电网中发电机组的集成是智能电网领域的主要研究课题之一。各国政府正在支持将中小型发电机直接连接到配电网,但随之而来的能源生产商数量的增加带来了若干技术问题。对于配电网的规划和运行,根据电能质量标准规定的限制估计最大可安装发电量是很重要的。近年来,为了考虑到与网络可靠运行相关的不同方面,提出并设计了几种评估承载能力(HC)的方法。然而,许多方法没有考虑到分布式发电并网分配的影响,特别是分布式发电在电厂实现前的位置未知。本文提出了一种新的基于网络拥塞风险的HC计算方法。除了经典的电压和电流约束外,该方法还集成了分布式发电的随机分配,并分别评估了它们对HC值的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Hosting capacity of distribution networks: Evaluation of the network congestion risk due to distributed generation
The integration of generation units in distribution grids is one of the main research topics in the field of smart grids. Governments are supporting the connection of small/medium size generators directly to the distribution network, but the consequent growing number of energy producers poses several technical issues. For the planning and operation of a distribution network it is then important to estimate the maximum installable generation according to the limits imposed by the power quality standards. In the recent years, several methods for the evaluation of the Hosting Capacity (HC) has been proposed and designed in order to take into account different aspects related to the reliable operation of the network. However, many methods are not taking into account the effects of the grid allocation of distributed generation and, especially, the unknown position of it before the power plants realization. The paper describes a novel solution to compute the HC on the basis of the risk of network congestion. In addition to the classical voltage and current constraints, the proposed approach also integrates the stochastic allocation of distributed generation and separately evaluates their impact on the HC value.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A single input dual buck-boost output reconfigurable converter for distributed generation Overhead transmission lines dynamic line rating estimation in WAMS environments Fast estimation of MPPs in mismatched PV arrays based on lossless model Frontiers of photovoltaic technology: A review Risk-based probabilistic approach to estimate power system security in the Sicilian context
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1