LC滤波器在谐波抑制中的应用

N. Mahamad, M. Hadzer, Syafrudin Masri
{"title":"LC滤波器在谐波抑制中的应用","authors":"N. Mahamad, M. Hadzer, Syafrudin Masri","doi":"10.1109/PECON.2004.1461656","DOIUrl":null,"url":null,"abstract":"In recent years, harmonics are considered as one of the most essential problems in electrical power systems. Even though, this new highly efficient electronic technology provides improved product quality with increased productivity by the use of smaller and lighter electrical components but they are the sources of harmonics. Recent surveys on the three-phase four-wire electric power distribution systems with computer and nonlinear loads show excessive currents in the neutral conductor. The neutral currents are basically zero-sequence current harmonics, which is mostly, consists of triplen current harmonics. As a result, the perfect sinusoidal voltage and current waveform are very much distorted. To solve this problem, a simple and practical approach to reduce harmonics current in 3-phase 4-wire power distribution system is proposed. The using of LC filter in three-phase four-wire system reduces the harmonic problem in the system. This LC filter is depending on value of capacitor and inductor. It is not only reducing zero-sequence harmonics but also reduce other harmonics in the system. Besides that, this application also can improve power factor and reduced the THD system to the standard IEEE-std 519. The practical excellency and validity of reducing are demonstrated experimentally.","PeriodicalId":375856,"journal":{"name":"PECon 2004. Proceedings. National Power and Energy Conference, 2004.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2004-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Application of LC filter in harmonics reduction\",\"authors\":\"N. Mahamad, M. Hadzer, Syafrudin Masri\",\"doi\":\"10.1109/PECON.2004.1461656\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In recent years, harmonics are considered as one of the most essential problems in electrical power systems. Even though, this new highly efficient electronic technology provides improved product quality with increased productivity by the use of smaller and lighter electrical components but they are the sources of harmonics. Recent surveys on the three-phase four-wire electric power distribution systems with computer and nonlinear loads show excessive currents in the neutral conductor. The neutral currents are basically zero-sequence current harmonics, which is mostly, consists of triplen current harmonics. As a result, the perfect sinusoidal voltage and current waveform are very much distorted. To solve this problem, a simple and practical approach to reduce harmonics current in 3-phase 4-wire power distribution system is proposed. The using of LC filter in three-phase four-wire system reduces the harmonic problem in the system. This LC filter is depending on value of capacitor and inductor. It is not only reducing zero-sequence harmonics but also reduce other harmonics in the system. Besides that, this application also can improve power factor and reduced the THD system to the standard IEEE-std 519. The practical excellency and validity of reducing are demonstrated experimentally.\",\"PeriodicalId\":375856,\"journal\":{\"name\":\"PECon 2004. Proceedings. National Power and Energy Conference, 2004.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-11-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PECon 2004. Proceedings. National Power and Energy Conference, 2004.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECON.2004.1461656\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PECon 2004. Proceedings. National Power and Energy Conference, 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECON.2004.1461656","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

近年来,谐波问题被认为是电力系统中最重要的问题之一。尽管如此,这种新的高效电子技术通过使用更小更轻的电子元件提高了产品质量和生产率,但它们是谐波的来源。最近对具有计算机和非线性负载的三相四线制配电系统的研究表明,中性导体电流过大。中性点电流基本为零序电流谐波,多由三次电流谐波组成。结果,完美的正弦电压和电流波形被严重扭曲。针对这一问题,提出了一种简单实用的减小三相四线制配电系统谐波电流的方法。LC滤波器在三相四线制系统中的应用,减少了系统中的谐波问题。此LC滤波器取决于电容器和电感的值。它不仅降低了零序谐波,而且降低了系统中的其他谐波。除此之外,该应用还可以提高功率因数,将THD系统降低到IEEE-std 519标准。实验证明了该方法的实用性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Application of LC filter in harmonics reduction
In recent years, harmonics are considered as one of the most essential problems in electrical power systems. Even though, this new highly efficient electronic technology provides improved product quality with increased productivity by the use of smaller and lighter electrical components but they are the sources of harmonics. Recent surveys on the three-phase four-wire electric power distribution systems with computer and nonlinear loads show excessive currents in the neutral conductor. The neutral currents are basically zero-sequence current harmonics, which is mostly, consists of triplen current harmonics. As a result, the perfect sinusoidal voltage and current waveform are very much distorted. To solve this problem, a simple and practical approach to reduce harmonics current in 3-phase 4-wire power distribution system is proposed. The using of LC filter in three-phase four-wire system reduces the harmonic problem in the system. This LC filter is depending on value of capacitor and inductor. It is not only reducing zero-sequence harmonics but also reduce other harmonics in the system. Besides that, this application also can improve power factor and reduced the THD system to the standard IEEE-std 519. The practical excellency and validity of reducing are demonstrated experimentally.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Application of improved genetic algorithms for loss minimisation in power system Implementation of different passive filter designs for harmonic mitigation A new single-phase two-wire hybrid active power filter using extension p-q theorem for photovoltaic application Voltage stability based weak area clustering technique in power system Calculation of static thrust on a linear DC actuator
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1