饱和条件下电流互感器性能的实验评价

P. Chawande, S. Soman, P. Apte, S. Pandit
{"title":"饱和条件下电流互感器性能的实验评价","authors":"P. Chawande, S. Soman, P. Apte, S. Pandit","doi":"10.1109/IPEC.2005.206882","DOIUrl":null,"url":null,"abstract":"Current transformers form an integral part of protective systems. Ideal current transformers (CTs) are expected to reproduce the primary current faithfully on the secondary side. Often, during fault conditions an important component of current is exponentially decaying DC offset current. Under such conditions the CT saturates, and hence it cannot reproduce the primary current faithfully. This paper deals with experimental methods for determining CT performance under saturation. A laboratory setup has been developed to observe CT response under steady state and fault conditions. Thus, it is now possible to experimentally evaluate the CT performance under fault conditions","PeriodicalId":164802,"journal":{"name":"2005 International Power Engineering Conference","volume":"87 11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Experimental evaluation of current transformer performance under saturation\",\"authors\":\"P. Chawande, S. Soman, P. Apte, S. Pandit\",\"doi\":\"10.1109/IPEC.2005.206882\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Current transformers form an integral part of protective systems. Ideal current transformers (CTs) are expected to reproduce the primary current faithfully on the secondary side. Often, during fault conditions an important component of current is exponentially decaying DC offset current. Under such conditions the CT saturates, and hence it cannot reproduce the primary current faithfully. This paper deals with experimental methods for determining CT performance under saturation. A laboratory setup has been developed to observe CT response under steady state and fault conditions. Thus, it is now possible to experimentally evaluate the CT performance under fault conditions\",\"PeriodicalId\":164802,\"journal\":{\"name\":\"2005 International Power Engineering Conference\",\"volume\":\"87 11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 International Power Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEC.2005.206882\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 International Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEC.2005.206882","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

电流互感器是保护系统的重要组成部分。理想的电流互感器(ct)被期望在二次侧忠实地再现一次电流。通常,在故障条件下,电流的一个重要组成部分是指数衰减的直流偏置电流。在这种情况下,CT饱和,因此它不能忠实地再现一次电流。本文讨论了饱和条件下CT性能测定的实验方法。建立了一个实验室装置来观察稳态和故障条件下的CT响应。因此,现在可以通过实验来评估CT在故障条件下的性能
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Experimental evaluation of current transformer performance under saturation
Current transformers form an integral part of protective systems. Ideal current transformers (CTs) are expected to reproduce the primary current faithfully on the secondary side. Often, during fault conditions an important component of current is exponentially decaying DC offset current. Under such conditions the CT saturates, and hence it cannot reproduce the primary current faithfully. This paper deals with experimental methods for determining CT performance under saturation. A laboratory setup has been developed to observe CT response under steady state and fault conditions. Thus, it is now possible to experimentally evaluate the CT performance under fault conditions
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The application of association rule mining in power system restoration The influence of model mismatch to power system calculation, part II: on the stability calculation Optimal participation of a microgrid to the energy market with an intelligent EMS An account of a modified lightning protection system for power stations An improved usage allocation method for deregulated transmission systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1