{"title":"基于LCL滤波器的分布式资源无缝传输控制算法研究","authors":"Shengli Huang, Li Kong, Haiping Xu","doi":"10.1109/DRPT.2008.4523888","DOIUrl":null,"url":null,"abstract":"Generally distributed resource (DR) with LCL-based grid inverter works as controlled current source in grid-connected mode, while operates in controlled voltage source in island. So in case of utility faults or intentional islanding, DR has to change its control strategy from controlled current source to controlled voltage source. This paper analyzes the transition between controlled current source and controlled voltage source on single-phase inverter and three-phase inverter, respectively, and then presents a novel control strategy based on controlled voltage mode whether connected to the grid or in stand-alone. Once the grid failure, this control strategy regulates the inverter output voltage amplitude quickly, which forces the grid currents through the SCR switches to decrease to zero at much less time and during this SCRs turn-off period, the voltage fluctuates within permissible levels. After disconnection from the grid, the inverter will recover its voltage amplitude to a rated level. The algorithm is discussed in this paper detailedly. Computer simulation and experiments proved the feasibility of this control scheme.","PeriodicalId":240420,"journal":{"name":"2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Control algorithm research on seamless transfer for distributed resource with a LCL filter\",\"authors\":\"Shengli Huang, Li Kong, Haiping Xu\",\"doi\":\"10.1109/DRPT.2008.4523888\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Generally distributed resource (DR) with LCL-based grid inverter works as controlled current source in grid-connected mode, while operates in controlled voltage source in island. So in case of utility faults or intentional islanding, DR has to change its control strategy from controlled current source to controlled voltage source. This paper analyzes the transition between controlled current source and controlled voltage source on single-phase inverter and three-phase inverter, respectively, and then presents a novel control strategy based on controlled voltage mode whether connected to the grid or in stand-alone. Once the grid failure, this control strategy regulates the inverter output voltage amplitude quickly, which forces the grid currents through the SCR switches to decrease to zero at much less time and during this SCRs turn-off period, the voltage fluctuates within permissible levels. After disconnection from the grid, the inverter will recover its voltage amplitude to a rated level. The algorithm is discussed in this paper detailedly. Computer simulation and experiments proved the feasibility of this control scheme.\",\"PeriodicalId\":240420,\"journal\":{\"name\":\"2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies\",\"volume\":\"66 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-04-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DRPT.2008.4523888\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DRPT.2008.4523888","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

基于lcl的分布式电网逆变器在并网模式下作为可控电流源,在孤岛模式下作为可控电压源。因此,当出现公用事业故障或人为孤岛时,DR必须将控制策略从受控电流源改为受控电压源。本文分别分析了单相逆变器和三相逆变器在受控电流源和受控电压源之间的转换,提出了一种基于受控电压模式的新型控制策略,无论并网还是单机。一旦电网发生故障,这种控制策略可以快速调节逆变器输出电压幅值,从而迫使通过可控硅开关的电网电流在更短的时间内降至零,并且在可控硅关断期间,电压在允许的水平内波动。脱离电网后,逆变器将恢复其电压幅值到额定水平。本文对该算法进行了详细的讨论。计算机仿真和实验证明了该控制方案的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Control algorithm research on seamless transfer for distributed resource with a LCL filter
Generally distributed resource (DR) with LCL-based grid inverter works as controlled current source in grid-connected mode, while operates in controlled voltage source in island. So in case of utility faults or intentional islanding, DR has to change its control strategy from controlled current source to controlled voltage source. This paper analyzes the transition between controlled current source and controlled voltage source on single-phase inverter and three-phase inverter, respectively, and then presents a novel control strategy based on controlled voltage mode whether connected to the grid or in stand-alone. Once the grid failure, this control strategy regulates the inverter output voltage amplitude quickly, which forces the grid currents through the SCR switches to decrease to zero at much less time and during this SCRs turn-off period, the voltage fluctuates within permissible levels. After disconnection from the grid, the inverter will recover its voltage amplitude to a rated level. The algorithm is discussed in this paper detailedly. Computer simulation and experiments proved the feasibility of this control scheme.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Transmission loss allocation using normalized loss weight factors Congestion management based on dynamic zoning and coordinated auctioning method Experimental study on the magnetic-controlled switcher type fault current limiter The simulating research on a improved magnetic shielding type of HTSCFCL Distribution feeder one-line diagrams automatic generation from geographic diagrams based on GIS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1