{"title":"残差发生器用于心血管异常检测","authors":"Z. Belkhatir, T. Laleg‐Kirati, M. Tadjine","doi":"10.1109/ECC.2014.6862573","DOIUrl":null,"url":null,"abstract":"This paper discusses the possibility of using observer-based approaches for cardiovascular anomalies detection and isolation. We consider a lumped parameter model of the cardiovascular system that can be written in a form of nonlinear state-space representation. We show that residuals that are sensitive to variations in some cardiovascular parameters and to abnormal opening and closure of the valves, can be generated. Since the whole state is not easily available for measurement, we propose to associate the residual generator to a robust extended kalman filter. Numerical results performed on synthetic data are provided.","PeriodicalId":251538,"journal":{"name":"2014 European Control Conference (ECC)","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Residual generator for cardiovascular anomalies detection\",\"authors\":\"Z. Belkhatir, T. Laleg‐Kirati, M. Tadjine\",\"doi\":\"10.1109/ECC.2014.6862573\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses the possibility of using observer-based approaches for cardiovascular anomalies detection and isolation. We consider a lumped parameter model of the cardiovascular system that can be written in a form of nonlinear state-space representation. We show that residuals that are sensitive to variations in some cardiovascular parameters and to abnormal opening and closure of the valves, can be generated. Since the whole state is not easily available for measurement, we propose to associate the residual generator to a robust extended kalman filter. Numerical results performed on synthetic data are provided.\",\"PeriodicalId\":251538,\"journal\":{\"name\":\"2014 European Control Conference (ECC)\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 European Control Conference (ECC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECC.2014.6862573\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 European Control Conference (ECC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECC.2014.6862573","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Residual generator for cardiovascular anomalies detection
This paper discusses the possibility of using observer-based approaches for cardiovascular anomalies detection and isolation. We consider a lumped parameter model of the cardiovascular system that can be written in a form of nonlinear state-space representation. We show that residuals that are sensitive to variations in some cardiovascular parameters and to abnormal opening and closure of the valves, can be generated. Since the whole state is not easily available for measurement, we propose to associate the residual generator to a robust extended kalman filter. Numerical results performed on synthetic data are provided.