{"title":"ITER中导流器扫瞄的热效应","authors":"J. Wesley","doi":"10.1109/FUSION.1991.218695","DOIUrl":null,"url":null,"abstract":"Thermal effects of magnetically sweeping the separatrix strike point on the outer divertor target of the ITER are calculated. For the 0.2 Hz*+or-12 cm sweep scenario proposed for ITER operations, the thermal capability of a generic target design is found to be slightly inadequate (by approximately 5%) to accommodate the full degree of plasma scrape-off peaking postulated as a design basis. The principal problem identified is that the 5-s sweep period is long relative to the 1.4-s thermal time constant of the divertor target. An increase of the sweep frequency to approximately 1 Hz is suggested; this increase would provide a power handling margin of approximately 25% relative to present operational criteria.<<ETX>>","PeriodicalId":318951,"journal":{"name":"[Proceedings] The 14th IEEE/NPSS Symposium Fusion Engineering","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Thermal effects of divertor sweeping in ITER\",\"authors\":\"J. Wesley\",\"doi\":\"10.1109/FUSION.1991.218695\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Thermal effects of magnetically sweeping the separatrix strike point on the outer divertor target of the ITER are calculated. For the 0.2 Hz*+or-12 cm sweep scenario proposed for ITER operations, the thermal capability of a generic target design is found to be slightly inadequate (by approximately 5%) to accommodate the full degree of plasma scrape-off peaking postulated as a design basis. The principal problem identified is that the 5-s sweep period is long relative to the 1.4-s thermal time constant of the divertor target. An increase of the sweep frequency to approximately 1 Hz is suggested; this increase would provide a power handling margin of approximately 25% relative to present operational criteria.<<ETX>>\",\"PeriodicalId\":318951,\"journal\":{\"name\":\"[Proceedings] The 14th IEEE/NPSS Symposium Fusion Engineering\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[Proceedings] The 14th IEEE/NPSS Symposium Fusion Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FUSION.1991.218695\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[Proceedings] The 14th IEEE/NPSS Symposium Fusion Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FUSION.1991.218695","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Thermal effects of magnetically sweeping the separatrix strike point on the outer divertor target of the ITER are calculated. For the 0.2 Hz*+or-12 cm sweep scenario proposed for ITER operations, the thermal capability of a generic target design is found to be slightly inadequate (by approximately 5%) to accommodate the full degree of plasma scrape-off peaking postulated as a design basis. The principal problem identified is that the 5-s sweep period is long relative to the 1.4-s thermal time constant of the divertor target. An increase of the sweep frequency to approximately 1 Hz is suggested; this increase would provide a power handling margin of approximately 25% relative to present operational criteria.<>