[神经外科血管手术中的神经生理监测:具体技术要求及其转换]。

H Hinrichs, H J Heinze, M R Gaab
{"title":"[神经外科血管手术中的神经生理监测:具体技术要求及其转换]。","authors":"H Hinrichs,&nbsp;H J Heinze,&nbsp;M R Gaab","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Several authors have presented evidence for a strict relation between regional cerebral blood flow and EEG. Therefore the EEG can serve as an adequate physiological parameter when monitoring cerebral function in the operating room. However, to exploit the inherent information as far as possible, both multichannel EEG and somatosensory evoked potentials should be recorded simultaneously. In the present article we describe a monitoring system which is capable to handle this task under the conditions of an operating room. In the first step some numerically simple algorithms are applied to detect gross artifacts. In the subsequent processing stage an analysis procedure is performed which is robust with respect to the remaining more subtile artifacts. In addition the raw signals are continually displayed on a monitor to allow for a visual evaluation of the EEG. The results of a trend analysis procedure are presented on the same graphical display by means of a compact topographical scheme. The system has been running under routine conditions for approximately two years now.</p>","PeriodicalId":75812,"journal":{"name":"EEG-EMG Zeitschrift fur Elektroenzephalographie, Elektromyographie und verwandte Gebiete","volume":"23 4","pages":"195-202"},"PeriodicalIF":0.0000,"publicationDate":"1992-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Neurophysiologic monitoring in neurosurgical vascular operations: specific technical requirements and their conversion].\",\"authors\":\"H Hinrichs,&nbsp;H J Heinze,&nbsp;M R Gaab\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Several authors have presented evidence for a strict relation between regional cerebral blood flow and EEG. Therefore the EEG can serve as an adequate physiological parameter when monitoring cerebral function in the operating room. However, to exploit the inherent information as far as possible, both multichannel EEG and somatosensory evoked potentials should be recorded simultaneously. In the present article we describe a monitoring system which is capable to handle this task under the conditions of an operating room. In the first step some numerically simple algorithms are applied to detect gross artifacts. In the subsequent processing stage an analysis procedure is performed which is robust with respect to the remaining more subtile artifacts. In addition the raw signals are continually displayed on a monitor to allow for a visual evaluation of the EEG. The results of a trend analysis procedure are presented on the same graphical display by means of a compact topographical scheme. The system has been running under routine conditions for approximately two years now.</p>\",\"PeriodicalId\":75812,\"journal\":{\"name\":\"EEG-EMG Zeitschrift fur Elektroenzephalographie, Elektromyographie und verwandte Gebiete\",\"volume\":\"23 4\",\"pages\":\"195-202\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EEG-EMG Zeitschrift fur Elektroenzephalographie, Elektromyographie und verwandte Gebiete\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EEG-EMG Zeitschrift fur Elektroenzephalographie, Elektromyographie und verwandte Gebiete","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

一些作者已经提出证据表明脑血流与脑电图之间有严格的关系。因此,脑电图可以作为手术室监测脑功能的一个充分的生理参数。然而,为了尽可能挖掘其固有的信息,需要同时记录多通道脑电图和体感诱发电位。在本文中,我们描述了一个能够在手术室条件下处理这项任务的监测系统。在第一步中,应用一些数值上简单的算法来检测粗伪影。在随后的处理阶段,执行相对于剩余的更细微的工件具有鲁棒性的分析程序。此外,原始信号连续显示在监视器上,以便对脑电图进行视觉评估。趋势分析程序的结果通过紧凑的地形方案呈现在同一图形显示上。该系统已经在常规条件下运行了大约两年。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Neurophysiologic monitoring in neurosurgical vascular operations: specific technical requirements and their conversion].

Several authors have presented evidence for a strict relation between regional cerebral blood flow and EEG. Therefore the EEG can serve as an adequate physiological parameter when monitoring cerebral function in the operating room. However, to exploit the inherent information as far as possible, both multichannel EEG and somatosensory evoked potentials should be recorded simultaneously. In the present article we describe a monitoring system which is capable to handle this task under the conditions of an operating room. In the first step some numerically simple algorithms are applied to detect gross artifacts. In the subsequent processing stage an analysis procedure is performed which is robust with respect to the remaining more subtile artifacts. In addition the raw signals are continually displayed on a monitor to allow for a visual evaluation of the EEG. The results of a trend analysis procedure are presented on the same graphical display by means of a compact topographical scheme. The system has been running under routine conditions for approximately two years now.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Team Training of Inter-Professional Students (TTIPS) for improving teamwork. [Subdivision of Ia fibers of de-efferented cat muscle spindles into two groups]. [Control of isometric muscle contraction in muscle hypotonia of central origin: EMG mapping analysis]. [Jaw opening reflex: a new electrophysiologic method for objective assessment of trigeminal sensory disorders. I. Method and normal values]. [Clinical application of quantitative evaluation of horizontal pursuit movements of the eye].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1