消弧电抗器电网负荷仿真及稳态状态计算

S. Girshin, V. Goryunov, E. Kuznetsov, E. Petrova, D. Osipov
{"title":"消弧电抗器电网负荷仿真及稳态状态计算","authors":"S. Girshin, V. Goryunov, E. Kuznetsov, E. Petrova, D. Osipov","doi":"10.1109/ELEKTRO.2016.7512083","DOIUrl":null,"url":null,"abstract":"The problem of modeling electrical loads in the calculation of modes of electric networks with controllable arc extinguish reactor with asymmetry modes is considered. The model is based on the simplifying assumption of constant power load permitting the use of a minimum set of input data. The equations are obtained using methods of phase coordinates and symmetrical components. The model is a formula of nonlinear transformation of phase voltages in phase load currents with the double exception of zero sequence. It is shown that even with a significant bias of neutral conductor load currents using this model are almost symmetrical. The proposed model of the load can be used to calculate the normal net mode with arc extinguish reactor, as well as to calculate the single phase-to-earth fault modes.","PeriodicalId":369251,"journal":{"name":"2016 ELEKTRO","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Simulation of electrical loads for the steady-state regime calculation of electric grids with arc extinguish reactor\",\"authors\":\"S. Girshin, V. Goryunov, E. Kuznetsov, E. Petrova, D. Osipov\",\"doi\":\"10.1109/ELEKTRO.2016.7512083\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The problem of modeling electrical loads in the calculation of modes of electric networks with controllable arc extinguish reactor with asymmetry modes is considered. The model is based on the simplifying assumption of constant power load permitting the use of a minimum set of input data. The equations are obtained using methods of phase coordinates and symmetrical components. The model is a formula of nonlinear transformation of phase voltages in phase load currents with the double exception of zero sequence. It is shown that even with a significant bias of neutral conductor load currents using this model are almost symmetrical. The proposed model of the load can be used to calculate the normal net mode with arc extinguish reactor, as well as to calculate the single phase-to-earth fault modes.\",\"PeriodicalId\":369251,\"journal\":{\"name\":\"2016 ELEKTRO\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 ELEKTRO\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELEKTRO.2016.7512083\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 ELEKTRO","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELEKTRO.2016.7512083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

考虑了具有非对称模态的可控灭弧电抗器电网模态计算中的负荷建模问题。该模型基于允许使用最小输入数据集的恒定电力负荷的简化假设。采用相坐标法和对称分量法得到了方程。该模型是在零序双例外情况下相负载电流中相电压的非线性变换公式。结果表明,即使中性导体有明显的偏置,使用该模型的负载电流也几乎是对称的。所建立的负荷模型可用于灭弧电抗器正常网络模式的计算,也可用于单相接地故障模式的计算。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Simulation of electrical loads for the steady-state regime calculation of electric grids with arc extinguish reactor
The problem of modeling electrical loads in the calculation of modes of electric networks with controllable arc extinguish reactor with asymmetry modes is considered. The model is based on the simplifying assumption of constant power load permitting the use of a minimum set of input data. The equations are obtained using methods of phase coordinates and symmetrical components. The model is a formula of nonlinear transformation of phase voltages in phase load currents with the double exception of zero sequence. It is shown that even with a significant bias of neutral conductor load currents using this model are almost symmetrical. The proposed model of the load can be used to calculate the normal net mode with arc extinguish reactor, as well as to calculate the single phase-to-earth fault modes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Linear features of robot servo-system controlled in sliding mode Patch antenna optimization in COMSOL multiphysics Mathematical model of electric energy losses calculating in crosslinked four-wire polyethylene insulated (XLPE) aerial bundled cables Research and development in collaboration with private sectors: Applications of electronics and computer technology in the fields of medical science, ergonomics and assistive technology Load torque impact on DC motor current control accuracy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1