{"title":"利用蓄电池储能系统实现各种常规控制器的多区域负荷变频控制","authors":"Pradipkumar Prajapati, Ashokkumar Parmar","doi":"10.1109/ICEETS.2016.7583800","DOIUrl":null,"url":null,"abstract":"The main objective of the power system is to provide good quality of power to the consumer. Continuous change in frequency by variation in load is a big challenge for generating unit to compensate it quickly as possible. Load Frequency Control (LFC) acts essential role to mitigate this problem by maintaining the frequency up to its desired level. PI and PID are conventional controllers can be used for LFC. Battery Energy Storage System (BESS) gives better results than conventional controllers. With the help of BES System voltage can be build up to, as many systems required. But if conventional controllers and BES System used together then more effective result can be achieved rather than their individual use for LFC. This paper presents a comparison of multi-area LFC with and without conventional controllers and conventional controllers in the presence of BES System. By using these both strategies together gives the best result as which system required.","PeriodicalId":215798,"journal":{"name":"2016 International Conference on Energy Efficient Technologies for Sustainability (ICEETS)","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"Multi-area Load Frequency Control by various conventional controller using Battery Energy Storage System\",\"authors\":\"Pradipkumar Prajapati, Ashokkumar Parmar\",\"doi\":\"10.1109/ICEETS.2016.7583800\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main objective of the power system is to provide good quality of power to the consumer. Continuous change in frequency by variation in load is a big challenge for generating unit to compensate it quickly as possible. Load Frequency Control (LFC) acts essential role to mitigate this problem by maintaining the frequency up to its desired level. PI and PID are conventional controllers can be used for LFC. Battery Energy Storage System (BESS) gives better results than conventional controllers. With the help of BES System voltage can be build up to, as many systems required. But if conventional controllers and BES System used together then more effective result can be achieved rather than their individual use for LFC. This paper presents a comparison of multi-area LFC with and without conventional controllers and conventional controllers in the presence of BES System. By using these both strategies together gives the best result as which system required.\",\"PeriodicalId\":215798,\"journal\":{\"name\":\"2016 International Conference on Energy Efficient Technologies for Sustainability (ICEETS)\",\"volume\":\"52 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 International Conference on Energy Efficient Technologies for Sustainability (ICEETS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEETS.2016.7583800\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Conference on Energy Efficient Technologies for Sustainability (ICEETS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEETS.2016.7583800","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Multi-area Load Frequency Control by various conventional controller using Battery Energy Storage System
The main objective of the power system is to provide good quality of power to the consumer. Continuous change in frequency by variation in load is a big challenge for generating unit to compensate it quickly as possible. Load Frequency Control (LFC) acts essential role to mitigate this problem by maintaining the frequency up to its desired level. PI and PID are conventional controllers can be used for LFC. Battery Energy Storage System (BESS) gives better results than conventional controllers. With the help of BES System voltage can be build up to, as many systems required. But if conventional controllers and BES System used together then more effective result can be achieved rather than their individual use for LFC. This paper presents a comparison of multi-area LFC with and without conventional controllers and conventional controllers in the presence of BES System. By using these both strategies together gives the best result as which system required.