基于电感电压特征的串联谐振DC-DC变换器全桥整流器短路故障检测与修复

Abualkasim Bakeer, A. Chub, D. Vinnikov
{"title":"基于电感电压特征的串联谐振DC-DC变换器全桥整流器短路故障检测与修复","authors":"Abualkasim Bakeer, A. Chub, D. Vinnikov","doi":"10.1109/RTUCON51174.2020.9316482","DOIUrl":null,"url":null,"abstract":"This paper proposes a method to detect the short-circuit fault (SCF) in the full-bridge diode rectifier at the output side of the series resonant dc-dc converter (SRC). The full-bridge inverter is employed at the input side. The utilized diagnostic/signature signal to detect the SCF is the voltage of the resonant inductor, which increases after fault occurrence. Also, sensing the inductor voltage is an easy way through inserting a few turns into the core of the resonant inductor without affecting its operation. The sensed inductor voltage is compared with a threshold voltage, which is calculated based on the converter parameters. After the identification of the SCF fault, the input-side bridge is reconfigured into a half-bridge structure to recover the normal operation of the converter because the output side is operating as a voltage doubler in this case. Since in the proposed method, localization of the exact faulty diode is not considered important in the further operation, fast recovery of the fault condition can be achieved. The simulation results provided show the feasibility of the detection algorithm and the remedial action at different operating conditions.","PeriodicalId":332414,"journal":{"name":"2020 IEEE 61th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Short-Circuit Fault Detection and Remedial in Full-Bridge Rectifier of Series Resonant DC-DC Converter Based on Inductor Voltage Signature\",\"authors\":\"Abualkasim Bakeer, A. Chub, D. Vinnikov\",\"doi\":\"10.1109/RTUCON51174.2020.9316482\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a method to detect the short-circuit fault (SCF) in the full-bridge diode rectifier at the output side of the series resonant dc-dc converter (SRC). The full-bridge inverter is employed at the input side. The utilized diagnostic/signature signal to detect the SCF is the voltage of the resonant inductor, which increases after fault occurrence. Also, sensing the inductor voltage is an easy way through inserting a few turns into the core of the resonant inductor without affecting its operation. The sensed inductor voltage is compared with a threshold voltage, which is calculated based on the converter parameters. After the identification of the SCF fault, the input-side bridge is reconfigured into a half-bridge structure to recover the normal operation of the converter because the output side is operating as a voltage doubler in this case. Since in the proposed method, localization of the exact faulty diode is not considered important in the further operation, fast recovery of the fault condition can be achieved. The simulation results provided show the feasibility of the detection algorithm and the remedial action at different operating conditions.\",\"PeriodicalId\":332414,\"journal\":{\"name\":\"2020 IEEE 61th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-11-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 61th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RTUCON51174.2020.9316482\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 61th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RTUCON51174.2020.9316482","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

提出了一种检测串联谐振dc-dc变换器(SRC)输出侧全桥二极管整流器短路故障(SCF)的方法。输入端采用全桥逆变器。用于检测SCF的诊断/签名信号是谐振电感的电压,故障发生后电压升高。此外,感应电感电压是一个简单的方法,通过插入几个匝到谐振电感的核心,而不影响其操作。将感应到的电感电压与基于变换器参数计算的阈值电压进行比较。在识别出SCF故障后,输入侧桥被重新配置为半桥结构,以恢复转换器的正常运行,因为在这种情况下,输出侧作为倍压器运行。由于该方法在后续操作中不考虑故障二极管的精确定位,因此可以实现故障状态的快速恢复。仿真结果表明了该检测算法的可行性以及在不同工况下的补救措施。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Short-Circuit Fault Detection and Remedial in Full-Bridge Rectifier of Series Resonant DC-DC Converter Based on Inductor Voltage Signature
This paper proposes a method to detect the short-circuit fault (SCF) in the full-bridge diode rectifier at the output side of the series resonant dc-dc converter (SRC). The full-bridge inverter is employed at the input side. The utilized diagnostic/signature signal to detect the SCF is the voltage of the resonant inductor, which increases after fault occurrence. Also, sensing the inductor voltage is an easy way through inserting a few turns into the core of the resonant inductor without affecting its operation. The sensed inductor voltage is compared with a threshold voltage, which is calculated based on the converter parameters. After the identification of the SCF fault, the input-side bridge is reconfigured into a half-bridge structure to recover the normal operation of the converter because the output side is operating as a voltage doubler in this case. Since in the proposed method, localization of the exact faulty diode is not considered important in the further operation, fast recovery of the fault condition can be achieved. The simulation results provided show the feasibility of the detection algorithm and the remedial action at different operating conditions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Measuring the impact of demand response services on electricity prices in Latvian electricity market Case Studies for Optimal Cable Line Placement and Sheath Grounding to Increase its Operational Characteristics Reduction of Electromagnetic Emissions Generated by Inductive Resonant WPT Systems Using Multi-Switching-Frequency-Based Method Economic Assessment Of The Efficiency Of The Application Of Energy Storage System To Compensate The Load Rise And Shedding Of Gas Piston Installation Control Algorithms Based on Load Angle and Phase Current Difference for Traction Switched Reluctance Motor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1