用于远程医疗系统鲁棒传输的高频传感器

Yi-hao Shen, K. Tsang, I. Triantis, Tony Chi Chung Lee
{"title":"用于远程医疗系统鲁棒传输的高频传感器","authors":"Yi-hao Shen, K. Tsang, I. Triantis, Tony Chi Chung Lee","doi":"10.1109/INDIN.2016.7819307","DOIUrl":null,"url":null,"abstract":"This paper introduces a high frequency Point-to-Point (PtP) Microwave Transmitter Module for Telemedicine for hospital(s). Such a telemedicine system links up remote communities from one building to another in hospital environment. The network configurations of the high frequency microwave system are illustrated in details. Key advantages such as high capacity, long propagation distance, and wide range of frequency bands are described. The high frequency PtP serves as a repeater so that paramedical staff or nurse(s) may receive data at appropriate time. Hence important tasks such as first aid, doctor's diagnosis and instructions to patients may be performed through the telemedicine system. This paper describes the design of a telemedicine system based on a high linearity Ku-band transmitter module that can improve the capacity (data rate) as well as increased the propagation distance. The module operates between 13 ∼ 15.5 GHz and achieves 25 dB of gain and 33 dBm of output power at 1dB gain compression. The third order intermodulation (IM3) is −41 dBc at 22 dBm Pout/tone, when the two-tone space is 600KMz at the high centre frequency of 15GHz.","PeriodicalId":421680,"journal":{"name":"2016 IEEE 14th International Conference on Industrial Informatics (INDIN)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"High frequency sensors for robust transmission in telemedicine system\",\"authors\":\"Yi-hao Shen, K. Tsang, I. Triantis, Tony Chi Chung Lee\",\"doi\":\"10.1109/INDIN.2016.7819307\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper introduces a high frequency Point-to-Point (PtP) Microwave Transmitter Module for Telemedicine for hospital(s). Such a telemedicine system links up remote communities from one building to another in hospital environment. The network configurations of the high frequency microwave system are illustrated in details. Key advantages such as high capacity, long propagation distance, and wide range of frequency bands are described. The high frequency PtP serves as a repeater so that paramedical staff or nurse(s) may receive data at appropriate time. Hence important tasks such as first aid, doctor's diagnosis and instructions to patients may be performed through the telemedicine system. This paper describes the design of a telemedicine system based on a high linearity Ku-band transmitter module that can improve the capacity (data rate) as well as increased the propagation distance. The module operates between 13 ∼ 15.5 GHz and achieves 25 dB of gain and 33 dBm of output power at 1dB gain compression. The third order intermodulation (IM3) is −41 dBc at 22 dBm Pout/tone, when the two-tone space is 600KMz at the high centre frequency of 15GHz.\",\"PeriodicalId\":421680,\"journal\":{\"name\":\"2016 IEEE 14th International Conference on Industrial Informatics (INDIN)\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE 14th International Conference on Industrial Informatics (INDIN)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INDIN.2016.7819307\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 14th International Conference on Industrial Informatics (INDIN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INDIN.2016.7819307","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

介绍了一种用于医院远程医疗的高频点对点微波发射机模块。这种远程医疗系统在医院环境中将偏远社区从一栋楼连接到另一栋楼。详细说明了高频微波系统的网络结构。介绍了该系统具有容量大、传播距离长、频带范围广等主要优点。高频PtP充当中继器,以便辅助医务人员或护士可以在适当的时间接收数据。因此,诸如急救、医生诊断和对病人的指导等重要任务可以通过远程医疗系统来完成。本文介绍了一种基于高线性度ku波段发射机模块的远程医疗系统的设计,该模块可以提高远程医疗系统的容量(数据速率),并增加远程医疗系统的传播距离。该模块工作在13 ~ 15.5 GHz之间,在1dB增益压缩下可实现25db增益和33dbm输出功率。三阶互调(IM3)在22dbm Pout/tone时为- 41 dBc,当两音空间为600KMz时,高中心频率为15GHz。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High frequency sensors for robust transmission in telemedicine system
This paper introduces a high frequency Point-to-Point (PtP) Microwave Transmitter Module for Telemedicine for hospital(s). Such a telemedicine system links up remote communities from one building to another in hospital environment. The network configurations of the high frequency microwave system are illustrated in details. Key advantages such as high capacity, long propagation distance, and wide range of frequency bands are described. The high frequency PtP serves as a repeater so that paramedical staff or nurse(s) may receive data at appropriate time. Hence important tasks such as first aid, doctor's diagnosis and instructions to patients may be performed through the telemedicine system. This paper describes the design of a telemedicine system based on a high linearity Ku-band transmitter module that can improve the capacity (data rate) as well as increased the propagation distance. The module operates between 13 ∼ 15.5 GHz and achieves 25 dB of gain and 33 dBm of output power at 1dB gain compression. The third order intermodulation (IM3) is −41 dBc at 22 dBm Pout/tone, when the two-tone space is 600KMz at the high centre frequency of 15GHz.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
LPV modelling and LPV observer-based fault detection for wind turbine systems Determining the optimal level of autonomy in cyber-physical production systems Detecting illegally parked vehicle based on cumulative dual foreground difference An electronic stethoscope for heart diseases based on micro-electro-mechanical-system microphone A PID controller for the underwater robot station-keeping
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1