一种在电力变压器中应用快速瞬变的装置

H. Martins, L. T. B. Santos
{"title":"一种在电力变压器中应用快速瞬变的装置","authors":"H. Martins, L. T. B. Santos","doi":"10.1109/ICHVE.2010.5640752","DOIUrl":null,"url":null,"abstract":"This paper presents the development of a device capable of generating very fast transient signals typically found in SF6 Gas Insulated Substations (GIS), originated from disconnector switchings or the occurrence of disruptive discharge to ground. Substations where power transformers are coupled to GIS, such signals are presented as a potential source of failure as a function of dielectric request imposed. This device is basically a variable \"gap\" made of special spheres, inserted in a pressurized SF6 compartment between a SF6/Air passing bushing and a 6power transformer. Using this set-up, triggered by self discharge, associated an adequate procedure; it is possible to test the supportability of bushings and transformers to dielectric requests of steep and fast front waves.","PeriodicalId":287425,"journal":{"name":"2010 International Conference on High Voltage Engineering and Application","volume":"165 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A set-up to apply very-fast transients in power transformers\",\"authors\":\"H. Martins, L. T. B. Santos\",\"doi\":\"10.1109/ICHVE.2010.5640752\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the development of a device capable of generating very fast transient signals typically found in SF6 Gas Insulated Substations (GIS), originated from disconnector switchings or the occurrence of disruptive discharge to ground. Substations where power transformers are coupled to GIS, such signals are presented as a potential source of failure as a function of dielectric request imposed. This device is basically a variable \\\"gap\\\" made of special spheres, inserted in a pressurized SF6 compartment between a SF6/Air passing bushing and a 6power transformer. Using this set-up, triggered by self discharge, associated an adequate procedure; it is possible to test the supportability of bushings and transformers to dielectric requests of steep and fast front waves.\",\"PeriodicalId\":287425,\"journal\":{\"name\":\"2010 International Conference on High Voltage Engineering and Application\",\"volume\":\"165 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on High Voltage Engineering and Application\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVE.2010.5640752\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on High Voltage Engineering and Application","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE.2010.5640752","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了一种能够产生非常快的瞬态信号的装置,这种信号通常出现在SF6气体绝缘变电站(GIS)中,源于隔离开关或对地破坏性放电的发生。在电力变压器与GIS耦合的变电站中,这些信号作为施加的介电要求的函数呈现为潜在的故障源。该装置基本上是由特殊球体制成的可变“间隙”,插入SF6/空气通过套管和6功率变压器之间的加压SF6隔间中。使用这种装置,由自放电触发,关联一个适当的程序;可以测试套管和变压器对陡峭和快速前波的介电要求的支持性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A set-up to apply very-fast transients in power transformers
This paper presents the development of a device capable of generating very fast transient signals typically found in SF6 Gas Insulated Substations (GIS), originated from disconnector switchings or the occurrence of disruptive discharge to ground. Substations where power transformers are coupled to GIS, such signals are presented as a potential source of failure as a function of dielectric request imposed. This device is basically a variable "gap" made of special spheres, inserted in a pressurized SF6 compartment between a SF6/Air passing bushing and a 6power transformer. Using this set-up, triggered by self discharge, associated an adequate procedure; it is possible to test the supportability of bushings and transformers to dielectric requests of steep and fast front waves.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Non-destructive test methods for hollow-core composite insulators Investigation of the effect of conductor temperature on AC power line corona Field characteristics and dielectric tests on an IGBT module plate Ultra wide band response of partial discharge test circuit The expert transformer monitoring system in substation structure
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1