{"title":"电光传感器的有限元设计与分析","authors":"S. Laskar, P. Dutta, S. Sen","doi":"10.1109/ICIT.2000.854087","DOIUrl":null,"url":null,"abstract":"The paper presents design, development, and analysis of electro-optic sensor by using FEM. The electro-optic effect (Pockels effect) has been used for measurement of voltage of variable frequency where a lithium-niobate crystal, sandwiched between electrodes undergoes a change in its refractive index when subjected to applied voltage. Change in refractive index is converted to a corresponding change in intensity using polarimetric method to facilitate on line measurement. The intensity of the output light transmitted through the crystal changes as a function of the applied voltage. Therefore output voltage of the detector gives a measure of the voltage applied. Experimental work has been carried out to study the effect of sinusoidal and also pulse used as voltage sensor or field sensor with high and low applied voltage. Multielectrode configuration forms the basic structure of an electro-optic A/D converter where number of electrode is equal to the number of bits of the A/D converter. The nonlinearity of the electro-optic sensor is found as +0.97%. The maximum applied voltage is 150 V and the sensitivity is (0.02-0.04) volt/volt.","PeriodicalId":405648,"journal":{"name":"Proceedings of IEEE International Conference on Industrial Technology 2000 (IEEE Cat. No.00TH8482)","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design and analysis of electro optic sensor by finite element method\",\"authors\":\"S. Laskar, P. Dutta, S. Sen\",\"doi\":\"10.1109/ICIT.2000.854087\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents design, development, and analysis of electro-optic sensor by using FEM. The electro-optic effect (Pockels effect) has been used for measurement of voltage of variable frequency where a lithium-niobate crystal, sandwiched between electrodes undergoes a change in its refractive index when subjected to applied voltage. Change in refractive index is converted to a corresponding change in intensity using polarimetric method to facilitate on line measurement. The intensity of the output light transmitted through the crystal changes as a function of the applied voltage. Therefore output voltage of the detector gives a measure of the voltage applied. Experimental work has been carried out to study the effect of sinusoidal and also pulse used as voltage sensor or field sensor with high and low applied voltage. Multielectrode configuration forms the basic structure of an electro-optic A/D converter where number of electrode is equal to the number of bits of the A/D converter. The nonlinearity of the electro-optic sensor is found as +0.97%. The maximum applied voltage is 150 V and the sensitivity is (0.02-0.04) volt/volt.\",\"PeriodicalId\":405648,\"journal\":{\"name\":\"Proceedings of IEEE International Conference on Industrial Technology 2000 (IEEE Cat. No.00TH8482)\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-01-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of IEEE International Conference on Industrial Technology 2000 (IEEE Cat. No.00TH8482)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIT.2000.854087\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IEEE International Conference on Industrial Technology 2000 (IEEE Cat. No.00TH8482)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIT.2000.854087","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文采用有限元法对电光传感器进行了设计、开发和分析。电光效应(Pockels效应)已被用于测量频率可变的电压,其中夹在电极之间的铌酸锂晶体在施加电压时经历折射率的变化。利用偏振法将折射率的变化转换为相应的强度变化,以方便在线测量。通过晶体的输出光的强度随施加电压的变化而变化。因此,检测器的输出电压给出了施加电压的度量。实验研究了正弦和脉冲在高、低外加电压下用作电压传感器或场传感器的效果。多电极配置构成了电光A/D转换器的基本结构,其中电极数等于A/D转换器的位数。电光传感器的非线性系数为+0.97%。最大施加电压为150v,灵敏度为(0.02-0.04)伏/伏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design and analysis of electro optic sensor by finite element method
The paper presents design, development, and analysis of electro-optic sensor by using FEM. The electro-optic effect (Pockels effect) has been used for measurement of voltage of variable frequency where a lithium-niobate crystal, sandwiched between electrodes undergoes a change in its refractive index when subjected to applied voltage. Change in refractive index is converted to a corresponding change in intensity using polarimetric method to facilitate on line measurement. The intensity of the output light transmitted through the crystal changes as a function of the applied voltage. Therefore output voltage of the detector gives a measure of the voltage applied. Experimental work has been carried out to study the effect of sinusoidal and also pulse used as voltage sensor or field sensor with high and low applied voltage. Multielectrode configuration forms the basic structure of an electro-optic A/D converter where number of electrode is equal to the number of bits of the A/D converter. The nonlinearity of the electro-optic sensor is found as +0.97%. The maximum applied voltage is 150 V and the sensitivity is (0.02-0.04) volt/volt.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Identification of nonlinear nonautonomous state space systems from input-output measurements On stabilizing gains far digital control systems Developing an experimental mobile robot-ROVEL Failure detection/management in launch vehicle avionics Static UPS failures-origin and possible prevention
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1