{"title":"配电网动态变压器额定值的实现","authors":"T. Jalal, N. Rashid, B. van Vliet","doi":"10.1109/POWERCON.2012.6401328","DOIUrl":null,"url":null,"abstract":"Unison Networks Limited is currently implementing Dynamic Transformer Rating (DTR) on most of the power transformers in its distribution network. The implementation involves 50 transformers across three different regions - Hawkes Bay, Taupo and Rotorua. The DTR scheme utilizes an in-house developed DTR algorithm that has been designed based on the IEC60076-7 Loading Guide for Oil Immersed Power Transformer Standard. The algorithm samples real time data from various sensors installed in the networks and translates them into dynamic rating and insulation loss of life information for each transformer.","PeriodicalId":176214,"journal":{"name":"2012 IEEE International Conference on Power System Technology (POWERCON)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":"{\"title\":\"Implementation of Dynamic Transformer Rating in a distribution network\",\"authors\":\"T. Jalal, N. Rashid, B. van Vliet\",\"doi\":\"10.1109/POWERCON.2012.6401328\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Unison Networks Limited is currently implementing Dynamic Transformer Rating (DTR) on most of the power transformers in its distribution network. The implementation involves 50 transformers across three different regions - Hawkes Bay, Taupo and Rotorua. The DTR scheme utilizes an in-house developed DTR algorithm that has been designed based on the IEC60076-7 Loading Guide for Oil Immersed Power Transformer Standard. The algorithm samples real time data from various sensors installed in the networks and translates them into dynamic rating and insulation loss of life information for each transformer.\",\"PeriodicalId\":176214,\"journal\":{\"name\":\"2012 IEEE International Conference on Power System Technology (POWERCON)\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE International Conference on Power System Technology (POWERCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/POWERCON.2012.6401328\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Conference on Power System Technology (POWERCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERCON.2012.6401328","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Implementation of Dynamic Transformer Rating in a distribution network
Unison Networks Limited is currently implementing Dynamic Transformer Rating (DTR) on most of the power transformers in its distribution network. The implementation involves 50 transformers across three different regions - Hawkes Bay, Taupo and Rotorua. The DTR scheme utilizes an in-house developed DTR algorithm that has been designed based on the IEC60076-7 Loading Guide for Oil Immersed Power Transformer Standard. The algorithm samples real time data from various sensors installed in the networks and translates them into dynamic rating and insulation loss of life information for each transformer.