{"title":"级联STATCOM阀组背靠背运行控制策略设计","authors":"Zongqiang Zheng","doi":"10.1109/IMCEC.2016.7867567","DOIUrl":null,"url":null,"abstract":"As the most important part of static synchronous generator (STATCOM), cascade valve group should be carried on the strict test, if the reliability of the device is high requirement. This paper presents a suitable control strategy for cascade valve group, and introduces the micro-grid islanding control. V/ƒ control is used as a modulation signal of link, it can provide the necessary support for system voltage and frequency. The control reference signal generation is used as another link modulation signal, meanwhile, a detailed design method of the connection reactor is proposed. Finally, the simulation model structure is consistent with the actual control system in PSCAD/EMTDC, verifies the correctness and feasibility of the control strategy.","PeriodicalId":218222,"journal":{"name":"2016 IEEE Advanced Information Management, Communicates, Electronic and Automation Control Conference (IMCEC)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design on control strategy for cascaded STATCOM valve group back-to-back running\",\"authors\":\"Zongqiang Zheng\",\"doi\":\"10.1109/IMCEC.2016.7867567\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As the most important part of static synchronous generator (STATCOM), cascade valve group should be carried on the strict test, if the reliability of the device is high requirement. This paper presents a suitable control strategy for cascade valve group, and introduces the micro-grid islanding control. V/ƒ control is used as a modulation signal of link, it can provide the necessary support for system voltage and frequency. The control reference signal generation is used as another link modulation signal, meanwhile, a detailed design method of the connection reactor is proposed. Finally, the simulation model structure is consistent with the actual control system in PSCAD/EMTDC, verifies the correctness and feasibility of the control strategy.\",\"PeriodicalId\":218222,\"journal\":{\"name\":\"2016 IEEE Advanced Information Management, Communicates, Electronic and Automation Control Conference (IMCEC)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Advanced Information Management, Communicates, Electronic and Automation Control Conference (IMCEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMCEC.2016.7867567\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Advanced Information Management, Communicates, Electronic and Automation Control Conference (IMCEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMCEC.2016.7867567","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design on control strategy for cascaded STATCOM valve group back-to-back running
As the most important part of static synchronous generator (STATCOM), cascade valve group should be carried on the strict test, if the reliability of the device is high requirement. This paper presents a suitable control strategy for cascade valve group, and introduces the micro-grid islanding control. V/ƒ control is used as a modulation signal of link, it can provide the necessary support for system voltage and frequency. The control reference signal generation is used as another link modulation signal, meanwhile, a detailed design method of the connection reactor is proposed. Finally, the simulation model structure is consistent with the actual control system in PSCAD/EMTDC, verifies the correctness and feasibility of the control strategy.