用工业次谐波继电器保护亚同步扭转相互作用条件

N. Perera, R. Midence, V. Liyanage
{"title":"用工业次谐波继电器保护亚同步扭转相互作用条件","authors":"N. Perera, R. Midence, V. Liyanage","doi":"10.1109/CPRE.2018.8349817","DOIUrl":null,"url":null,"abstract":"The Sub Synchronous Torsional Interaction (SSTI) conditions occurred due to the interactions of the generator-turbine systems and devices such as series compensated systems and HVDC systems has identified as harmful condition to avoid. Although it is a common practice to study and mitigate possibilities of SSTI conditions at system level designs, the power systems are not fully immune to SSTI conditions. This paper investigates the applicability of a numerical sub-harmonic relay for providing the protection against such SSTI conditions. Performance (accuracy and speed) of the proposed solution is investigated using various SSTI conditions injected into the relay.","PeriodicalId":285875,"journal":{"name":"2018 71st Annual Conference for Protective Relay Engineers (CPRE)","volume":"85 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Protection for sub synchronous torsional interaction conditions using an industrial sub-harmonic relay\",\"authors\":\"N. Perera, R. Midence, V. Liyanage\",\"doi\":\"10.1109/CPRE.2018.8349817\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Sub Synchronous Torsional Interaction (SSTI) conditions occurred due to the interactions of the generator-turbine systems and devices such as series compensated systems and HVDC systems has identified as harmful condition to avoid. Although it is a common practice to study and mitigate possibilities of SSTI conditions at system level designs, the power systems are not fully immune to SSTI conditions. This paper investigates the applicability of a numerical sub-harmonic relay for providing the protection against such SSTI conditions. Performance (accuracy and speed) of the proposed solution is investigated using various SSTI conditions injected into the relay.\",\"PeriodicalId\":285875,\"journal\":{\"name\":\"2018 71st Annual Conference for Protective Relay Engineers (CPRE)\",\"volume\":\"85 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 71st Annual Conference for Protective Relay Engineers (CPRE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPRE.2018.8349817\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 71st Annual Conference for Protective Relay Engineers (CPRE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPRE.2018.8349817","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

由于发电机组系统与串联补偿系统和高压直流系统等设备的相互作用而产生的亚同步扭转相互作用(SSTI)条件已被确定为应避免的有害条件。虽然在系统级设计中研究和减轻SSTI条件的可能性是一种常见的做法,但电力系统并不能完全免受SSTI条件的影响。本文研究了数值次谐波继电器对此类SSTI条件提供保护的适用性。使用注入继电器的各种SSTI条件对所提出的解决方案的性能(精度和速度)进行了研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Protection for sub synchronous torsional interaction conditions using an industrial sub-harmonic relay
The Sub Synchronous Torsional Interaction (SSTI) conditions occurred due to the interactions of the generator-turbine systems and devices such as series compensated systems and HVDC systems has identified as harmful condition to avoid. Although it is a common practice to study and mitigate possibilities of SSTI conditions at system level designs, the power systems are not fully immune to SSTI conditions. This paper investigates the applicability of a numerical sub-harmonic relay for providing the protection against such SSTI conditions. Performance (accuracy and speed) of the proposed solution is investigated using various SSTI conditions injected into the relay.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Correlating protective relay reports for system-wide, post-event analysis Back to the basics — Event analysis using symmetrical components Cyber security — Securing the protection and control relay communication in substation Communications assisted islanding detection: Contrasting direct transfer trip and phase comparison methods Applying intelligent fast load shed using IEC 61850 GOOSE
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1