{"title":"使用同步相量和互联网协议电信的反孤岛检测","authors":"D. Laverty, D. Morrow, R. Best, M. Cregan","doi":"10.1109/ISGTEurope.2011.6162664","DOIUrl":null,"url":null,"abstract":"This paper presents a method of improving anti-islanding detection for distributed generation by application of a wide-area measurement system. Present anti-islanding solutions were developed when installed capacity of distributed generation was low. Issues such as nuisance tripping, cascade tripping and poor anti-islanding detection sensitivity common with present solutions could be justified since distributed generation did not represent a substantial in-feed to the national grid. Today, the installed capacity of distributed generation constitutes a significant proportion of system demand. Consequently the problems with present anti-islanding solutions require a solution. This paper will describe in detail how the proposed system achieves this in an intuitive and cost effective manner and has the potential to be a component of a Smart Grid. A wide area measurement system based on Phasor Measurement Unit (PMU) technology provides distributed generators with live, real-time, data from secure points on the national grid. This data is communicated via a robust, secure, Internet Protocol (IPv6) telecommunications network.","PeriodicalId":419250,"journal":{"name":"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"34","resultStr":"{\"title\":\"Anti-islanding detection using Synchrophasors and Internet Protocol telecommunications\",\"authors\":\"D. Laverty, D. Morrow, R. Best, M. Cregan\",\"doi\":\"10.1109/ISGTEurope.2011.6162664\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a method of improving anti-islanding detection for distributed generation by application of a wide-area measurement system. Present anti-islanding solutions were developed when installed capacity of distributed generation was low. Issues such as nuisance tripping, cascade tripping and poor anti-islanding detection sensitivity common with present solutions could be justified since distributed generation did not represent a substantial in-feed to the national grid. Today, the installed capacity of distributed generation constitutes a significant proportion of system demand. Consequently the problems with present anti-islanding solutions require a solution. This paper will describe in detail how the proposed system achieves this in an intuitive and cost effective manner and has the potential to be a component of a Smart Grid. A wide area measurement system based on Phasor Measurement Unit (PMU) technology provides distributed generators with live, real-time, data from secure points on the national grid. This data is communicated via a robust, secure, Internet Protocol (IPv6) telecommunications network.\",\"PeriodicalId\":419250,\"journal\":{\"name\":\"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"34\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEurope.2011.6162664\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEurope.2011.6162664","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Anti-islanding detection using Synchrophasors and Internet Protocol telecommunications
This paper presents a method of improving anti-islanding detection for distributed generation by application of a wide-area measurement system. Present anti-islanding solutions were developed when installed capacity of distributed generation was low. Issues such as nuisance tripping, cascade tripping and poor anti-islanding detection sensitivity common with present solutions could be justified since distributed generation did not represent a substantial in-feed to the national grid. Today, the installed capacity of distributed generation constitutes a significant proportion of system demand. Consequently the problems with present anti-islanding solutions require a solution. This paper will describe in detail how the proposed system achieves this in an intuitive and cost effective manner and has the potential to be a component of a Smart Grid. A wide area measurement system based on Phasor Measurement Unit (PMU) technology provides distributed generators with live, real-time, data from secure points on the national grid. This data is communicated via a robust, secure, Internet Protocol (IPv6) telecommunications network.