使用同步相量和互联网协议电信的反孤岛检测

D. Laverty, D. Morrow, R. Best, M. Cregan
{"title":"使用同步相量和互联网协议电信的反孤岛检测","authors":"D. Laverty, D. Morrow, R. Best, M. Cregan","doi":"10.1109/ISGTEurope.2011.6162664","DOIUrl":null,"url":null,"abstract":"This paper presents a method of improving anti-islanding detection for distributed generation by application of a wide-area measurement system. Present anti-islanding solutions were developed when installed capacity of distributed generation was low. Issues such as nuisance tripping, cascade tripping and poor anti-islanding detection sensitivity common with present solutions could be justified since distributed generation did not represent a substantial in-feed to the national grid. Today, the installed capacity of distributed generation constitutes a significant proportion of system demand. Consequently the problems with present anti-islanding solutions require a solution. This paper will describe in detail how the proposed system achieves this in an intuitive and cost effective manner and has the potential to be a component of a Smart Grid. A wide area measurement system based on Phasor Measurement Unit (PMU) technology provides distributed generators with live, real-time, data from secure points on the national grid. This data is communicated via a robust, secure, Internet Protocol (IPv6) telecommunications network.","PeriodicalId":419250,"journal":{"name":"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"34","resultStr":"{\"title\":\"Anti-islanding detection using Synchrophasors and Internet Protocol telecommunications\",\"authors\":\"D. Laverty, D. Morrow, R. Best, M. Cregan\",\"doi\":\"10.1109/ISGTEurope.2011.6162664\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a method of improving anti-islanding detection for distributed generation by application of a wide-area measurement system. Present anti-islanding solutions were developed when installed capacity of distributed generation was low. Issues such as nuisance tripping, cascade tripping and poor anti-islanding detection sensitivity common with present solutions could be justified since distributed generation did not represent a substantial in-feed to the national grid. Today, the installed capacity of distributed generation constitutes a significant proportion of system demand. Consequently the problems with present anti-islanding solutions require a solution. This paper will describe in detail how the proposed system achieves this in an intuitive and cost effective manner and has the potential to be a component of a Smart Grid. A wide area measurement system based on Phasor Measurement Unit (PMU) technology provides distributed generators with live, real-time, data from secure points on the national grid. This data is communicated via a robust, secure, Internet Protocol (IPv6) telecommunications network.\",\"PeriodicalId\":419250,\"journal\":{\"name\":\"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"34\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEurope.2011.6162664\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEurope.2011.6162664","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 34

摘要

本文通过广域测量系统的应用,提出了一种改进分布式发电防孤岛检测的方法。目前的防孤岛解决方案是在分布式发电装机容量较低的情况下发展起来的。目前解决方案中常见的麻烦跳闸、级联跳闸和抗孤岛检测灵敏度差等问题可能是合理的,因为分布式发电并不代表国家电网的大量输入。如今,分布式发电的装机容量占系统需求的很大比例。因此,目前反孤岛解决办法的问题需要一个解决办法。本文将详细描述所提出的系统如何以直观和经济有效的方式实现这一目标,并具有成为智能电网组成部分的潜力。基于相量测量单元(PMU)技术的广域测量系统为分布式发电机提供来自国家电网安全点的实时数据。这些数据通过稳健、安全的互联网协议(IPv6)电信网络进行通信。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Anti-islanding detection using Synchrophasors and Internet Protocol telecommunications
This paper presents a method of improving anti-islanding detection for distributed generation by application of a wide-area measurement system. Present anti-islanding solutions were developed when installed capacity of distributed generation was low. Issues such as nuisance tripping, cascade tripping and poor anti-islanding detection sensitivity common with present solutions could be justified since distributed generation did not represent a substantial in-feed to the national grid. Today, the installed capacity of distributed generation constitutes a significant proportion of system demand. Consequently the problems with present anti-islanding solutions require a solution. This paper will describe in detail how the proposed system achieves this in an intuitive and cost effective manner and has the potential to be a component of a Smart Grid. A wide area measurement system based on Phasor Measurement Unit (PMU) technology provides distributed generators with live, real-time, data from secure points on the national grid. This data is communicated via a robust, secure, Internet Protocol (IPv6) telecommunications network.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Power quality assessment of the Bogotá distribution network focused on voltage sag analysis Increasing security of supply by the use of a Local Power Controller during large system disturbances Realising the potential of smart grids in LV networks. Part 2: Microgeneration Multi-scale dynamic modeling to maximize demand side management Optimal fault location in distribution systems using distributed disturbance recordings
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1