IEEE电网直流偏置磁流分布同步监测指南

{"title":"IEEE电网直流偏置磁流分布同步监测指南","authors":"","doi":"10.1109/ieeestd.2021.9652507","DOIUrl":null,"url":null,"abstract":"The synchronous monitoring method, the layout principle, and the analysis of monitoring results of direct current (dc) magnetic bias current distribution on transmission networks 110 kV and above from transformers (including converter transformers) are specified in this guide. This guide does not discuss the effect of dc or geomagnetically induced current (GIC) on transformers.","PeriodicalId":151473,"journal":{"name":"IEEE Std 2869-2021","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"IEEE Guide for the Synchronous Monitoring of Direct Current (DC) Bias Magnetic Current Distribution in Power Grid\",\"authors\":\"\",\"doi\":\"10.1109/ieeestd.2021.9652507\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The synchronous monitoring method, the layout principle, and the analysis of monitoring results of direct current (dc) magnetic bias current distribution on transmission networks 110 kV and above from transformers (including converter transformers) are specified in this guide. This guide does not discuss the effect of dc or geomagnetically induced current (GIC) on transformers.\",\"PeriodicalId\":151473,\"journal\":{\"name\":\"IEEE Std 2869-2021\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Std 2869-2021\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ieeestd.2021.9652507\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Std 2869-2021","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ieeestd.2021.9652507","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本指南规定了110 kV及以上输电网变压器(含换流变压器)直流偏磁电流分布的同步监测方法、布设原则和监测结果分析。本指南不讨论直流或地磁感应电流(GIC)对变压器的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
IEEE Guide for the Synchronous Monitoring of Direct Current (DC) Bias Magnetic Current Distribution in Power Grid
The synchronous monitoring method, the layout principle, and the analysis of monitoring results of direct current (dc) magnetic bias current distribution on transmission networks 110 kV and above from transformers (including converter transformers) are specified in this guide. This guide does not discuss the effect of dc or geomagnetically induced current (GIC) on transformers.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
IEEE Guide for the Synchronous Monitoring of Direct Current (DC) Bias Magnetic Current Distribution in Power Grid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1