Jacques Wattel, M. Tomlinson, J. Beukes, T. Mouton
{"title":"使用智能电表对低压馈线进行连续线路阻抗评估","authors":"Jacques Wattel, M. Tomlinson, J. Beukes, T. Mouton","doi":"10.1109/ISGTEurope.2018.8571667","DOIUrl":null,"url":null,"abstract":"This paper investigates the use of smart meters to measure the line impedance of LV feeders to provide information on the adequacy of protection settings, deteriorating infrastructure, damaged infrastructure, etc. The consequences of a broken neutral conductor are examined for the two earthing schemes used in South Africa. The feasibility of measuring the line impedance using smart meters is evaluated using an experimental model of an LV feeder with experimental smart meters located at customer installations. Experimental results showed that the smart meters can be used to estimate the line impedance to detect a possible broken neutral or protective earth and neutral conductor failure.","PeriodicalId":302863,"journal":{"name":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","volume":"71 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Continuous Line Impedance Assessment of LV Feeders Using Smart Meters\",\"authors\":\"Jacques Wattel, M. Tomlinson, J. Beukes, T. Mouton\",\"doi\":\"10.1109/ISGTEurope.2018.8571667\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper investigates the use of smart meters to measure the line impedance of LV feeders to provide information on the adequacy of protection settings, deteriorating infrastructure, damaged infrastructure, etc. The consequences of a broken neutral conductor are examined for the two earthing schemes used in South Africa. The feasibility of measuring the line impedance using smart meters is evaluated using an experimental model of an LV feeder with experimental smart meters located at customer installations. Experimental results showed that the smart meters can be used to estimate the line impedance to detect a possible broken neutral or protective earth and neutral conductor failure.\",\"PeriodicalId\":302863,\"journal\":{\"name\":\"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"volume\":\"71 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEurope.2018.8571667\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEurope.2018.8571667","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Continuous Line Impedance Assessment of LV Feeders Using Smart Meters
This paper investigates the use of smart meters to measure the line impedance of LV feeders to provide information on the adequacy of protection settings, deteriorating infrastructure, damaged infrastructure, etc. The consequences of a broken neutral conductor are examined for the two earthing schemes used in South Africa. The feasibility of measuring the line impedance using smart meters is evaluated using an experimental model of an LV feeder with experimental smart meters located at customer installations. Experimental results showed that the smart meters can be used to estimate the line impedance to detect a possible broken neutral or protective earth and neutral conductor failure.