用LCL滤波器稳定三相电压源逆变器的比例谐振控制器

M. S. Quinalia, R. F. Magossi, P. G. B. Ferreira, R. Machado, V. Oliveira
{"title":"用LCL滤波器稳定三相电压源逆变器的比例谐振控制器","authors":"M. S. Quinalia, R. F. Magossi, P. G. B. Ferreira, R. Machado, V. Oliveira","doi":"10.1109/COBEP.2017.8257421","DOIUrl":null,"url":null,"abstract":"Applications with traditional voltage source inverters (VSIs) usually demand low THD output voltage regardless the load. The proportional-resonant (PR) controller have been used instead of a classical proportional-integral-derivative (PID) controller to track a sinusoidal reference waveform and improve the dynamical response of a specific VSI. Once the interest of knowing the stabilizing set to the controllers has increased, in this paper it is presented, based on Routh-Hurwitz criterion, the stabilizing set of a system with a PR and a three-phase VSI with a LCL filter. Moreover, the inverter circuitry model and the set of PR-controller gains were validated based on Matlab and PSIM simulation results.","PeriodicalId":375493,"journal":{"name":"2017 Brazilian Power Electronics Conference (COBEP)","volume":"225 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Stabilizing sets of proportional-resonant controllers for three-phase voltage source inverters with a LCL filter\",\"authors\":\"M. S. Quinalia, R. F. Magossi, P. G. B. Ferreira, R. Machado, V. Oliveira\",\"doi\":\"10.1109/COBEP.2017.8257421\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Applications with traditional voltage source inverters (VSIs) usually demand low THD output voltage regardless the load. The proportional-resonant (PR) controller have been used instead of a classical proportional-integral-derivative (PID) controller to track a sinusoidal reference waveform and improve the dynamical response of a specific VSI. Once the interest of knowing the stabilizing set to the controllers has increased, in this paper it is presented, based on Routh-Hurwitz criterion, the stabilizing set of a system with a PR and a three-phase VSI with a LCL filter. Moreover, the inverter circuitry model and the set of PR-controller gains were validated based on Matlab and PSIM simulation results.\",\"PeriodicalId\":375493,\"journal\":{\"name\":\"2017 Brazilian Power Electronics Conference (COBEP)\",\"volume\":\"225 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 Brazilian Power Electronics Conference (COBEP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/COBEP.2017.8257421\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Brazilian Power Electronics Conference (COBEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COBEP.2017.8257421","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

传统电压源逆变器(vsi)的应用通常要求低THD输出电压,无论负载如何。采用比例谐振(PR)控制器代替传统的比例积分导数(PID)控制器来跟踪正弦参考波形,改善特定VSI的动态响应。当人们对控制器的稳定集越来越感兴趣时,本文基于Routh-Hurwitz准则,给出了带LCL滤波器的带PR和三相VSI系统的稳定集。此外,基于Matlab和PSIM仿真结果验证了逆变电路模型和pr控制器增益集。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Stabilizing sets of proportional-resonant controllers for three-phase voltage source inverters with a LCL filter
Applications with traditional voltage source inverters (VSIs) usually demand low THD output voltage regardless the load. The proportional-resonant (PR) controller have been used instead of a classical proportional-integral-derivative (PID) controller to track a sinusoidal reference waveform and improve the dynamical response of a specific VSI. Once the interest of knowing the stabilizing set to the controllers has increased, in this paper it is presented, based on Routh-Hurwitz criterion, the stabilizing set of a system with a PR and a three-phase VSI with a LCL filter. Moreover, the inverter circuitry model and the set of PR-controller gains were validated based on Matlab and PSIM simulation results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Inverter-based motor drive systems: An overview from the electromagnetic compatibility perspective Impact of PV systems on microgrids under different levels of penetration and operational scenarios A case study of adaptive microgrid protection during transitions and operations An alternative analysis of AC-AC PWM converter voltage stabilizer Performance comparison of IGBTS and SIC-MOSFET applied in photovoltaic inverters during reactive power injection
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1