A. Lay-Ekuakille, G. Griffo, Joël Kidiamboko Kitoko, R. Velázquez, J. Garcia
{"title":"基础设施健康感知中表达准确性的评估指标:输水管道泄漏案例研究","authors":"A. Lay-Ekuakille, G. Griffo, Joël Kidiamboko Kitoko, R. Velázquez, J. Garcia","doi":"10.1109/ICSENST.2017.8304517","DOIUrl":null,"url":null,"abstract":"Structural health monitoring is part of a broad topic involving diverse engineering disciplines. Thanks to advances in ICT (information communication technology), in particular, in sensors; nowadays, it is possible to monitor the structural health of diverse infrastructures, and civil constructions. However, in many cases, the efficiency of sensing systems is not pointed out because experts always focus on primary results but not on the accuracy especially for structures located in non-seismic areas. The paper presents analytical description of necessary indicators for expressing uncertainty and accuracy in detecting cracks on water pipelines that cause leakage. The technique we employ here, to process data from magnetic sensors mounted on the pipe, is based on FDM (filter diagonalization technique), capable of yielding promising results in detecting leaks during water flow by processing electrical signals from the aforementioned sensors.","PeriodicalId":289209,"journal":{"name":"2017 Eleventh International Conference on Sensing Technology (ICST)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Assessment indicators for expressing accuracy in sensing infrastructure health: Case study of leakage in water pipelines\",\"authors\":\"A. Lay-Ekuakille, G. Griffo, Joël Kidiamboko Kitoko, R. Velázquez, J. Garcia\",\"doi\":\"10.1109/ICSENST.2017.8304517\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Structural health monitoring is part of a broad topic involving diverse engineering disciplines. Thanks to advances in ICT (information communication technology), in particular, in sensors; nowadays, it is possible to monitor the structural health of diverse infrastructures, and civil constructions. However, in many cases, the efficiency of sensing systems is not pointed out because experts always focus on primary results but not on the accuracy especially for structures located in non-seismic areas. The paper presents analytical description of necessary indicators for expressing uncertainty and accuracy in detecting cracks on water pipelines that cause leakage. The technique we employ here, to process data from magnetic sensors mounted on the pipe, is based on FDM (filter diagonalization technique), capable of yielding promising results in detecting leaks during water flow by processing electrical signals from the aforementioned sensors.\",\"PeriodicalId\":289209,\"journal\":{\"name\":\"2017 Eleventh International Conference on Sensing Technology (ICST)\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 Eleventh International Conference on Sensing Technology (ICST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENST.2017.8304517\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Eleventh International Conference on Sensing Technology (ICST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2017.8304517","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Assessment indicators for expressing accuracy in sensing infrastructure health: Case study of leakage in water pipelines
Structural health monitoring is part of a broad topic involving diverse engineering disciplines. Thanks to advances in ICT (information communication technology), in particular, in sensors; nowadays, it is possible to monitor the structural health of diverse infrastructures, and civil constructions. However, in many cases, the efficiency of sensing systems is not pointed out because experts always focus on primary results but not on the accuracy especially for structures located in non-seismic areas. The paper presents analytical description of necessary indicators for expressing uncertainty and accuracy in detecting cracks on water pipelines that cause leakage. The technique we employ here, to process data from magnetic sensors mounted on the pipe, is based on FDM (filter diagonalization technique), capable of yielding promising results in detecting leaks during water flow by processing electrical signals from the aforementioned sensors.