种植体特性对即刻加载单种植体病例种植体稳定性的影响:一项前瞻性研究

K. Obagbemiro, Y. Ajayi, P. Akeredolu, John Adeoye, G. Arotiba
{"title":"种植体特性对即刻加载单种植体病例种植体稳定性的影响:一项前瞻性研究","authors":"K. Obagbemiro, Y. Ajayi, P. Akeredolu, John Adeoye, G. Arotiba","doi":"10.4103/JDI.JDI_12_18","DOIUrl":null,"url":null,"abstract":"Introduction: Factors that affect primary and ultimate implant stability include characteristics of the type of dental implant used, bone quality at the site of implant placement, insertion torque, as well as micromotions at the bone–implant interface. This study, however, sought out to determine the effect and relationship between relevant implant characteristics and implant stability in immediately loaded single implant cases using the Periotest® M handheld device. Aim: To determine the effect of implant characteristics on the ultimate implant stability in immediately loaded single implant cases. Results: At placement, 33 (94%) of implants had periotest values between −0.8 and 0 at placement. There is a general decrease in the number of patients with periotest values −0.8–0 and those with +1–9 from the initial placement to 6 months after placement. It was further observed that there is a negative correlation between the implant length, diameter, and the mean periotest values although this was not statistically significant. Conclusion: There is a directly proportional relationship between implant characteristics and implant stability of immediately loaded implants.","PeriodicalId":212982,"journal":{"name":"Journal of Dental Implants","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"The effect of implant characteristics on the implant stability of immediately loaded single implant cases: A prospective study\",\"authors\":\"K. Obagbemiro, Y. Ajayi, P. Akeredolu, John Adeoye, G. Arotiba\",\"doi\":\"10.4103/JDI.JDI_12_18\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Factors that affect primary and ultimate implant stability include characteristics of the type of dental implant used, bone quality at the site of implant placement, insertion torque, as well as micromotions at the bone–implant interface. This study, however, sought out to determine the effect and relationship between relevant implant characteristics and implant stability in immediately loaded single implant cases using the Periotest® M handheld device. Aim: To determine the effect of implant characteristics on the ultimate implant stability in immediately loaded single implant cases. Results: At placement, 33 (94%) of implants had periotest values between −0.8 and 0 at placement. There is a general decrease in the number of patients with periotest values −0.8–0 and those with +1–9 from the initial placement to 6 months after placement. It was further observed that there is a negative correlation between the implant length, diameter, and the mean periotest values although this was not statistically significant. Conclusion: There is a directly proportional relationship between implant characteristics and implant stability of immediately loaded implants.\",\"PeriodicalId\":212982,\"journal\":{\"name\":\"Journal of Dental Implants\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Dental Implants\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/JDI.JDI_12_18\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Implants","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/JDI.JDI_12_18","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

影响初级和最终种植体稳定性的因素包括所使用的牙种植体类型的特性、种植体放置部位的骨质量、插入扭矩以及骨-种植体界面的微运动。然而,本研究试图确定使用Periotest®M手持设备立即加载单种植体病例中相关种植体特性与种植体稳定性之间的影响和关系。目的:探讨种植体特性对即刻加载单种植体最终稳定性的影响。结果:放置时,33例(94%)种植体的牙周炎值在−0.8 ~ 0之间。从最初放置到放置后6个月,骨膜测试值为- 0.8-0和+ 1-9的患者数量普遍减少。我们进一步观察到种植体长度、直径和平均骨膜值之间存在负相关,尽管这没有统计学意义。结论:即刻加载种植体的种植体特性与种植体稳定性成正比关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The effect of implant characteristics on the implant stability of immediately loaded single implant cases: A prospective study
Introduction: Factors that affect primary and ultimate implant stability include characteristics of the type of dental implant used, bone quality at the site of implant placement, insertion torque, as well as micromotions at the bone–implant interface. This study, however, sought out to determine the effect and relationship between relevant implant characteristics and implant stability in immediately loaded single implant cases using the Periotest® M handheld device. Aim: To determine the effect of implant characteristics on the ultimate implant stability in immediately loaded single implant cases. Results: At placement, 33 (94%) of implants had periotest values between −0.8 and 0 at placement. There is a general decrease in the number of patients with periotest values −0.8–0 and those with +1–9 from the initial placement to 6 months after placement. It was further observed that there is a negative correlation between the implant length, diameter, and the mean periotest values although this was not statistically significant. Conclusion: There is a directly proportional relationship between implant characteristics and implant stability of immediately loaded implants.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Piezo osteotomy with all-on-4 implants to enable a full-arch rehabilitation A comparative evaluation of bite pressure between single implant prosthesis and natural teeth: An in-vivo study Two implant-retained mandibular overdenture using locator attachment – A clinical report Systemic medications and implant success: Is there a link? Part three: The effects of antiresorptive and anti-angiogenic agents on the outcome of implant therapy Gender-based predilection for the microbial load of Aggregatibacter actinomycetemcomitans present in anterior versus posterior implant sites: A preliminary observational study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1