{"title":"三维变换在医学图像压缩中的性能评价","authors":"R. Shyam Sunder, C. Eswaran, N. Sriraam","doi":"10.1109/EIT.2005.1627021","DOIUrl":null,"url":null,"abstract":"In this paper, 3-D discrete Hartley, cosine and Fourier transforms are used for the compression of magnetic resonance images and X-ray angiograms. The performance results are then compared and evaluated. The transforms are applied on image blocks of sizes 8times8timesM where M represents the number of slices. The resultant transform coefficients are quantized and then encoded using a combination of run length and Huffman coding schemes to achieve maximum compression. The performances of the transforms are evaluated in terms of peak signal to noise ratio and bit rate. It is found from the experimental results, that 3-D discrete Hartley transform yields the best results for magnetic resonance brain images whereas for X-ray angiograms the 3-D discrete cosine transform is found to be superior to the other two transforms","PeriodicalId":358002,"journal":{"name":"2005 IEEE International Conference on Electro Information Technology","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Performance evaluation of 3-D transforms for medical image compression\",\"authors\":\"R. Shyam Sunder, C. Eswaran, N. Sriraam\",\"doi\":\"10.1109/EIT.2005.1627021\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, 3-D discrete Hartley, cosine and Fourier transforms are used for the compression of magnetic resonance images and X-ray angiograms. The performance results are then compared and evaluated. The transforms are applied on image blocks of sizes 8times8timesM where M represents the number of slices. The resultant transform coefficients are quantized and then encoded using a combination of run length and Huffman coding schemes to achieve maximum compression. The performances of the transforms are evaluated in terms of peak signal to noise ratio and bit rate. It is found from the experimental results, that 3-D discrete Hartley transform yields the best results for magnetic resonance brain images whereas for X-ray angiograms the 3-D discrete cosine transform is found to be superior to the other two transforms\",\"PeriodicalId\":358002,\"journal\":{\"name\":\"2005 IEEE International Conference on Electro Information Technology\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 IEEE International Conference on Electro Information Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EIT.2005.1627021\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 IEEE International Conference on Electro Information Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIT.2005.1627021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

本文采用三维离散哈特利变换、余弦变换和傅立叶变换对磁共振图像和x射线血管成像进行压缩。然后对性能结果进行比较和评估。变换应用于大小为8times8timesM的图像块,其中M表示切片的数量。所得到的变换系数被量化,然后使用运行长度和霍夫曼编码方案的组合进行编码,以实现最大的压缩。用峰值信噪比和比特率来评价变换的性能。从实验结果中发现,三维离散哈特利变换对磁共振脑成像效果最好,而对于x射线血管成像,三维离散余弦变换优于其他两种变换
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance evaluation of 3-D transforms for medical image compression
In this paper, 3-D discrete Hartley, cosine and Fourier transforms are used for the compression of magnetic resonance images and X-ray angiograms. The performance results are then compared and evaluated. The transforms are applied on image blocks of sizes 8times8timesM where M represents the number of slices. The resultant transform coefficients are quantized and then encoded using a combination of run length and Huffman coding schemes to achieve maximum compression. The performances of the transforms are evaluated in terms of peak signal to noise ratio and bit rate. It is found from the experimental results, that 3-D discrete Hartley transform yields the best results for magnetic resonance brain images whereas for X-ray angiograms the 3-D discrete cosine transform is found to be superior to the other two transforms
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Carry-save and binary sign-digit representations conversion Energy macro-modeling of embedded microprocessor using SystemC A proportional rate-based control scheme for active queue management Hierarchical clustering for image databases Theft-induced checkpointing for reconfigurable dataflow applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1