{"title":"大功率连续波磁控管腔的热分析","authors":"Tong Feng, Dongping Gao, Zhaochuan Zhang","doi":"10.1109/IVEC.2015.7223834","DOIUrl":null,"url":null,"abstract":"A cooling system of a high-power Continuous Wave Magnetron (CWM) is devised with theoretical and numerical simulations. The temperature and heat distribution of the cavity is obtained utilizing ANSYS, and that is consistent with the situation under practical operation.","PeriodicalId":435469,"journal":{"name":"2015 IEEE International Vacuum Electronics Conference (IVEC)","volume":"143 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-08-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Thermal analysis of a high-power Continuous Wave Magnetron cavity\",\"authors\":\"Tong Feng, Dongping Gao, Zhaochuan Zhang\",\"doi\":\"10.1109/IVEC.2015.7223834\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A cooling system of a high-power Continuous Wave Magnetron (CWM) is devised with theoretical and numerical simulations. The temperature and heat distribution of the cavity is obtained utilizing ANSYS, and that is consistent with the situation under practical operation.\",\"PeriodicalId\":435469,\"journal\":{\"name\":\"2015 IEEE International Vacuum Electronics Conference (IVEC)\",\"volume\":\"143 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-08-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Vacuum Electronics Conference (IVEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IVEC.2015.7223834\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Vacuum Electronics Conference (IVEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IVEC.2015.7223834","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Thermal analysis of a high-power Continuous Wave Magnetron cavity
A cooling system of a high-power Continuous Wave Magnetron (CWM) is devised with theoretical and numerical simulations. The temperature and heat distribution of the cavity is obtained utilizing ANSYS, and that is consistent with the situation under practical operation.