{"title":"基于Android的预警系统,用于早期发现过敏反应","authors":"Estefania Munoz Diaz, R. Gutierrez-Rivas, J. J. García, W. Marnane, A. Jiménez, D. Gualda","doi":"10.1109/BSN.2017.7936027","DOIUrl":null,"url":null,"abstract":"This work proposes an Android-based platform to warn the medical staff of the onset of allergy reactions during a provocation test in a hospital. The portable system carries out the analysis of the heart rate variability for the early detection of allergic reactions in patients undergoing allergy provocation tests at hospitals. The proposal is composed of an ECG (electrocardiogram) acquisition system and an Android device (Smartphone, Tablet) that monitors and evaluates the results in real time, increasing the safety of allergic tests. At present, food and drug allergic tests are a major problem for patients because of their long duration and intrusion. However, the authors have designed an algorithm for detecting allergy reactions that have focused on reducing the time of the tests and the number of doses. This algorithm runs on an Android platform, and it is able to provide alarms for the medical staff if there is an allergy reaction. The proposed monitoring system is very suitable for the health monitoring during the provocation tests.","PeriodicalId":249670,"journal":{"name":"2017 IEEE 14th International Conference on Wearable and Implantable Body Sensor Networks (BSN)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Android based warning system for the early detection of allergic reactions\",\"authors\":\"Estefania Munoz Diaz, R. Gutierrez-Rivas, J. J. García, W. Marnane, A. Jiménez, D. Gualda\",\"doi\":\"10.1109/BSN.2017.7936027\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work proposes an Android-based platform to warn the medical staff of the onset of allergy reactions during a provocation test in a hospital. The portable system carries out the analysis of the heart rate variability for the early detection of allergic reactions in patients undergoing allergy provocation tests at hospitals. The proposal is composed of an ECG (electrocardiogram) acquisition system and an Android device (Smartphone, Tablet) that monitors and evaluates the results in real time, increasing the safety of allergic tests. At present, food and drug allergic tests are a major problem for patients because of their long duration and intrusion. However, the authors have designed an algorithm for detecting allergy reactions that have focused on reducing the time of the tests and the number of doses. This algorithm runs on an Android platform, and it is able to provide alarms for the medical staff if there is an allergy reaction. The proposed monitoring system is very suitable for the health monitoring during the provocation tests.\",\"PeriodicalId\":249670,\"journal\":{\"name\":\"2017 IEEE 14th International Conference on Wearable and Implantable Body Sensor Networks (BSN)\",\"volume\":\"48 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE 14th International Conference on Wearable and Implantable Body Sensor Networks (BSN)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BSN.2017.7936027\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE 14th International Conference on Wearable and Implantable Body Sensor Networks (BSN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BSN.2017.7936027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

这项工作提出了一个基于android的平台,在医院的刺激试验中警告医务人员过敏反应的发生。该便携式系统可对在医院进行过敏激发试验的患者进行心率变异性分析,以便早期发现过敏反应。该方案由一个ECG(心电图)采集系统和一个实时监测和评估结果的Android设备(智能手机、平板电脑)组成,提高了过敏测试的安全性。目前,食品和药物过敏试验因其持续时间长、侵入性强,是困扰患者的一大难题。然而,作者设计了一种检测过敏反应的算法,该算法的重点是减少测试的时间和剂量。该算法在Android平台上运行,如果出现过敏反应,可以向医护人员发出警报。该监测系统非常适用于激发试验期间的健康监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Android based warning system for the early detection of allergic reactions
This work proposes an Android-based platform to warn the medical staff of the onset of allergy reactions during a provocation test in a hospital. The portable system carries out the analysis of the heart rate variability for the early detection of allergic reactions in patients undergoing allergy provocation tests at hospitals. The proposal is composed of an ECG (electrocardiogram) acquisition system and an Android device (Smartphone, Tablet) that monitors and evaluates the results in real time, increasing the safety of allergic tests. At present, food and drug allergic tests are a major problem for patients because of their long duration and intrusion. However, the authors have designed an algorithm for detecting allergy reactions that have focused on reducing the time of the tests and the number of doses. This algorithm runs on an Android platform, and it is able to provide alarms for the medical staff if there is an allergy reaction. The proposed monitoring system is very suitable for the health monitoring during the provocation tests.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Radiowave propagation characteristics of the intra-body channel at 2.38 GHz Smart-shoe self-powered by walking A personalized air quality sensing system - a preliminary study on assessing the air quality of London underground stations Unsupervised deep representation learning to remove motion artifacts in free-mode body sensor networks Quantifying postural instability in Parkinsonian gait from inertial sensor data during standardised clinical gait tests
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1