M. Marzband, A. Sumper, O. Gomis‐Bellmunt, Paola Pezzini, M. Chindris
{"title":"采用模糊控制器和PID控制器对隔离型风柴油混合微电网进行频率控制","authors":"M. Marzband, A. Sumper, O. Gomis‐Bellmunt, Paola Pezzini, M. Chindris","doi":"10.1109/EPQU.2011.6128917","DOIUrl":null,"url":null,"abstract":"This paper presents a new application of fuzzy logic (FL) to1 an isolated network with a High Penetration, no-storage wind-diesel (HPNSWD) system. As a result of a study referring the behavior of an isolated electric system facing frequency disturbances, a fuzzy logic controller (FLC) was developed to improve the system´s dynamic performance. The validity of the proposed controller is evaluated by computer analysis using MATLAB/SIMULINK. The simulation results demonstrated that a small-scale wind turbine generation unit can be freely operated in an isolated distribution network without creating violation in power balance and voltage profile. The effectiveness of the fuzzy logic controller is then compared with that of a proportional-integral-and differential (PID) controller.","PeriodicalId":369941,"journal":{"name":"11th International Conference on Electrical Power Quality and Utilisation","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"34","resultStr":"{\"title\":\"Frequency control of isolated wind and diesel hybrid MicroGrid power system by using fuzzy logic controllers and PID controllers\",\"authors\":\"M. Marzband, A. Sumper, O. Gomis‐Bellmunt, Paola Pezzini, M. Chindris\",\"doi\":\"10.1109/EPQU.2011.6128917\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a new application of fuzzy logic (FL) to1 an isolated network with a High Penetration, no-storage wind-diesel (HPNSWD) system. As a result of a study referring the behavior of an isolated electric system facing frequency disturbances, a fuzzy logic controller (FLC) was developed to improve the system´s dynamic performance. The validity of the proposed controller is evaluated by computer analysis using MATLAB/SIMULINK. The simulation results demonstrated that a small-scale wind turbine generation unit can be freely operated in an isolated distribution network without creating violation in power balance and voltage profile. The effectiveness of the fuzzy logic controller is then compared with that of a proportional-integral-and differential (PID) controller.\",\"PeriodicalId\":369941,\"journal\":{\"name\":\"11th International Conference on Electrical Power Quality and Utilisation\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"34\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"11th International Conference on Electrical Power Quality and Utilisation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPQU.2011.6128917\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"11th International Conference on Electrical Power Quality and Utilisation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPQU.2011.6128917","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Frequency control of isolated wind and diesel hybrid MicroGrid power system by using fuzzy logic controllers and PID controllers
This paper presents a new application of fuzzy logic (FL) to1 an isolated network with a High Penetration, no-storage wind-diesel (HPNSWD) system. As a result of a study referring the behavior of an isolated electric system facing frequency disturbances, a fuzzy logic controller (FLC) was developed to improve the system´s dynamic performance. The validity of the proposed controller is evaluated by computer analysis using MATLAB/SIMULINK. The simulation results demonstrated that a small-scale wind turbine generation unit can be freely operated in an isolated distribution network without creating violation in power balance and voltage profile. The effectiveness of the fuzzy logic controller is then compared with that of a proportional-integral-and differential (PID) controller.