LC低通滤波器本质安全降压变换器输出电压纹波的简化计算方法

Yan Li, Shu-lin Liu, Hai-zhou Gao
{"title":"LC低通滤波器本质安全降压变换器输出电压纹波的简化计算方法","authors":"Yan Li, Shu-lin Liu, Hai-zhou Gao","doi":"10.1109/ICIEA.2019.8833828","DOIUrl":null,"url":null,"abstract":"Intrinsically safe Buck converter is an efficient DC-DC step-down switching circuit applied in flammable and explosive environment. The output voltage ripple (OVR) is an important electrical performance of the converter. It affected by switching frequency, filter inductance, capacitance, duty cycle, load resistance and other parameters. It is not easy to accurately calculate. The OVR calculation of the intrinsically safe Buck converter with LC low pass filter is more complicated compared with that of the traditional Buck converter. In this paper, an ideal circuit topology which is completely equivalent to the intrinsically safe Buck converter with LC low pass filter in continuous conduction mode (CCM) is constructed. By analyzing the frequency response of the equivalent circuit, the steady-state output characteristics of the circuit is obtained. Based on the voltage harmonic analysis, the OVR calculation method of the converter is obtained. Further ripple theoretical calculation and simulation analysis show that the fundamental ripple ratio can be equivalent to the total ripple ratio of the circuit completely and accurately in numerical computation. The final simulation results show that this method can effectively calculate the OVR of the intrinsically safe Buck converter with LC low pass filter.","PeriodicalId":311302,"journal":{"name":"2019 14th IEEE Conference on Industrial Electronics and Applications (ICIEA)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A Simplified Output Voltage Ripple Calculation Method of Intrinsically Safe Buck Converter with LC Low Pass Filter\",\"authors\":\"Yan Li, Shu-lin Liu, Hai-zhou Gao\",\"doi\":\"10.1109/ICIEA.2019.8833828\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Intrinsically safe Buck converter is an efficient DC-DC step-down switching circuit applied in flammable and explosive environment. The output voltage ripple (OVR) is an important electrical performance of the converter. It affected by switching frequency, filter inductance, capacitance, duty cycle, load resistance and other parameters. It is not easy to accurately calculate. The OVR calculation of the intrinsically safe Buck converter with LC low pass filter is more complicated compared with that of the traditional Buck converter. In this paper, an ideal circuit topology which is completely equivalent to the intrinsically safe Buck converter with LC low pass filter in continuous conduction mode (CCM) is constructed. By analyzing the frequency response of the equivalent circuit, the steady-state output characteristics of the circuit is obtained. Based on the voltage harmonic analysis, the OVR calculation method of the converter is obtained. Further ripple theoretical calculation and simulation analysis show that the fundamental ripple ratio can be equivalent to the total ripple ratio of the circuit completely and accurately in numerical computation. The final simulation results show that this method can effectively calculate the OVR of the intrinsically safe Buck converter with LC low pass filter.\",\"PeriodicalId\":311302,\"journal\":{\"name\":\"2019 14th IEEE Conference on Industrial Electronics and Applications (ICIEA)\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 14th IEEE Conference on Industrial Electronics and Applications (ICIEA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIEA.2019.8833828\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 14th IEEE Conference on Industrial Electronics and Applications (ICIEA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEA.2019.8833828","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本质安全Buck变换器是一种适用于易燃易爆环境的高效DC-DC降压开关电路。输出电压纹波(OVR)是变换器的一项重要的电气性能。它受开关频率、滤波器电感、电容、占空比、负载电阻等参数的影响。要准确计算是不容易的。与传统的Buck变换器相比,LC低通滤波器的本质安全Buck变换器的OVR计算更为复杂。本文构造了一种完全等价于连续导通模式下带LC低通滤波器的本质安全Buck变换器的理想电路拓扑结构。通过分析等效电路的频率响应,得到了该电路的稳态输出特性。在电压谐波分析的基础上,给出了变换器的OVR计算方法。进一步的纹波理论计算和仿真分析表明,在数值计算中,基波比可以完全准确地等效于电路的总纹波比。最后的仿真结果表明,该方法可以有效地计算出带有LC低通滤波器的本质安全Buck变换器的OVR。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Simplified Output Voltage Ripple Calculation Method of Intrinsically Safe Buck Converter with LC Low Pass Filter
Intrinsically safe Buck converter is an efficient DC-DC step-down switching circuit applied in flammable and explosive environment. The output voltage ripple (OVR) is an important electrical performance of the converter. It affected by switching frequency, filter inductance, capacitance, duty cycle, load resistance and other parameters. It is not easy to accurately calculate. The OVR calculation of the intrinsically safe Buck converter with LC low pass filter is more complicated compared with that of the traditional Buck converter. In this paper, an ideal circuit topology which is completely equivalent to the intrinsically safe Buck converter with LC low pass filter in continuous conduction mode (CCM) is constructed. By analyzing the frequency response of the equivalent circuit, the steady-state output characteristics of the circuit is obtained. Based on the voltage harmonic analysis, the OVR calculation method of the converter is obtained. Further ripple theoretical calculation and simulation analysis show that the fundamental ripple ratio can be equivalent to the total ripple ratio of the circuit completely and accurately in numerical computation. The final simulation results show that this method can effectively calculate the OVR of the intrinsically safe Buck converter with LC low pass filter.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Acoustic Sensors to Measure Speed of Oil Flow in Downhole Pipes Energy efficiency analysis of a liquefied natural gas and electric power combined transmission system Design and analysis of a novel tip-tilt stage with high precision for space applications Fault diagnosis of wind turbine bearing using synchrosqueezing wavelet transform and order analysis Smart Home Energy Management Optimization Method Considering ESS and PEV
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1