智能电网中信道感知MAC协议的性能评估

Abdulfattah Noorwali, R. Rao, A. Shami
{"title":"智能电网中信道感知MAC协议的性能评估","authors":"Abdulfattah Noorwali, R. Rao, A. Shami","doi":"10.1109/EPEC.2015.7379989","DOIUrl":null,"url":null,"abstract":"An Intelligent Distributed Channel-Aware Medium Access Control (IDCA-MAC) protocol is proposed for Home Area Network (HAN), in general, and for Electrical Devices Networks (EDN), in particular, in smart grids. In an EDN, electrical devices generate critical packets, and these must be communicated to their respective mesh clients. The proposed IDCA-MAC protocol employs simultaneous transmission of data packets through a single collision domain. Also, the electrical devices and the mesh client are assumed to be equipped with Multiple Input Multiple Output (MIMO) technology. The proposed protocol is compatible with the existing IEEE 802.11 standard, and uses channel-aware Medium Access Control (MA-Aware) and the Zig-Zag decoding algorithm. Simulations are carried out using the NS-2 network simulator, and the performance of IDCA-MAC protocol is evaluated for various smart grid scenarios that are of practical significance. It is shown that the protocol is very effective and can be easily adopted in existing smart grids for improved throughput and performance.","PeriodicalId":231255,"journal":{"name":"2015 IEEE Electrical Power and Energy Conference (EPEC)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Performance evaluation of Channel-Aware MAC protocol in smart grid\",\"authors\":\"Abdulfattah Noorwali, R. Rao, A. Shami\",\"doi\":\"10.1109/EPEC.2015.7379989\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An Intelligent Distributed Channel-Aware Medium Access Control (IDCA-MAC) protocol is proposed for Home Area Network (HAN), in general, and for Electrical Devices Networks (EDN), in particular, in smart grids. In an EDN, electrical devices generate critical packets, and these must be communicated to their respective mesh clients. The proposed IDCA-MAC protocol employs simultaneous transmission of data packets through a single collision domain. Also, the electrical devices and the mesh client are assumed to be equipped with Multiple Input Multiple Output (MIMO) technology. The proposed protocol is compatible with the existing IEEE 802.11 standard, and uses channel-aware Medium Access Control (MA-Aware) and the Zig-Zag decoding algorithm. Simulations are carried out using the NS-2 network simulator, and the performance of IDCA-MAC protocol is evaluated for various smart grid scenarios that are of practical significance. It is shown that the protocol is very effective and can be easily adopted in existing smart grids for improved throughput and performance.\",\"PeriodicalId\":231255,\"journal\":{\"name\":\"2015 IEEE Electrical Power and Energy Conference (EPEC)\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Electrical Power and Energy Conference (EPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPEC.2015.7379989\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Electrical Power and Energy Conference (EPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEC.2015.7379989","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

针对家庭区域网络(HAN)和电气设备网络(EDN),特别是智能电网,提出了一种智能分布式信道感知介质访问控制(IDCA-MAC)协议。在EDN中,电气设备生成关键数据包,这些数据包必须与各自的网格客户端通信。所提出的IDCA-MAC协议采用通过单个冲突域同时传输数据包的方式。此外,假定电气设备和网格客户端配备了多输入多输出(MIMO)技术。该协议兼容现有的IEEE 802.11标准,采用通道感知媒体访问控制(MA-Aware)和zigz - zag解码算法。利用NS-2网络模拟器进行了仿真,对IDCA-MAC协议在各种智能电网场景下的性能进行了评估,具有实际意义。实验表明,该协议是非常有效的,可以很容易地应用于现有的智能电网,以提高吞吐量和性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance evaluation of Channel-Aware MAC protocol in smart grid
An Intelligent Distributed Channel-Aware Medium Access Control (IDCA-MAC) protocol is proposed for Home Area Network (HAN), in general, and for Electrical Devices Networks (EDN), in particular, in smart grids. In an EDN, electrical devices generate critical packets, and these must be communicated to their respective mesh clients. The proposed IDCA-MAC protocol employs simultaneous transmission of data packets through a single collision domain. Also, the electrical devices and the mesh client are assumed to be equipped with Multiple Input Multiple Output (MIMO) technology. The proposed protocol is compatible with the existing IEEE 802.11 standard, and uses channel-aware Medium Access Control (MA-Aware) and the Zig-Zag decoding algorithm. Simulations are carried out using the NS-2 network simulator, and the performance of IDCA-MAC protocol is evaluated for various smart grid scenarios that are of practical significance. It is shown that the protocol is very effective and can be easily adopted in existing smart grids for improved throughput and performance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison between numerical and analytical methods of AC resistance evaluation for Medium Frequency Transformers: Validation on a prototype Improved control strategy of full-bridge modular multilevel converter Appliance scheduling optimization in smart home networks comprising of smart appliances and a photovoltaic panel Dynamic Reactive Power Compensation for voltage support using Static VAR Compensator (SVC) In Saudi Arabia Observability analysis of power systems in the presence of hybrid measurements
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1