径向电力系统故障引起的相电压行为:一种教育工具

G. Ramos, Ángela Espín-Delgado, J. Camarillo-Peñaranda
{"title":"径向电力系统故障引起的相电压行为:一种教育工具","authors":"G. Ramos, Ángela Espín-Delgado, J. Camarillo-Peñaranda","doi":"10.1109/PEPQA.2017.7981686","DOIUrl":null,"url":null,"abstract":"A study of the impact of the means of grounding on the voltage sag and swell characterization is presented in this paper. Only temporary overvoltages and undervoltages caused by faults are considered. The voltage divider model is employed, and the symmetrical components are used to obtain the phasor voltages at the point of common coupling as functions of the means of grounding of the system and the distance between the point of common coupling and the fault location. A computational tool that shows the phasor behavior during a fault event is developed. Also, a zone classification is proposed based on the location of voltage vectors depending on the fault type. This zone classification may be a cornerstone for new methods of fault classification and location in future works.","PeriodicalId":256426,"journal":{"name":"2017 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)","volume":"71 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Behavior of phase voltages due to faults in radial power systems: An educational tool\",\"authors\":\"G. Ramos, Ángela Espín-Delgado, J. Camarillo-Peñaranda\",\"doi\":\"10.1109/PEPQA.2017.7981686\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A study of the impact of the means of grounding on the voltage sag and swell characterization is presented in this paper. Only temporary overvoltages and undervoltages caused by faults are considered. The voltage divider model is employed, and the symmetrical components are used to obtain the phasor voltages at the point of common coupling as functions of the means of grounding of the system and the distance between the point of common coupling and the fault location. A computational tool that shows the phasor behavior during a fault event is developed. Also, a zone classification is proposed based on the location of voltage vectors depending on the fault type. This zone classification may be a cornerstone for new methods of fault classification and location in future works.\",\"PeriodicalId\":256426,\"journal\":{\"name\":\"2017 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)\",\"volume\":\"71 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEPQA.2017.7981686\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEPQA.2017.7981686","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文研究了接地方式对电压跌落和膨胀特性的影响。仅考虑故障引起的暂时性过压和欠压。采用分压器模型,采用对称分量作为系统接地方式和故障点距离的函数,得到共联轴点处的相量电压。开发了一种显示故障事件中相量行为的计算工具。此外,根据故障类型,提出了基于电压矢量位置的区域划分方法。这将为今后断层分类和定位的新方法奠定基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Behavior of phase voltages due to faults in radial power systems: An educational tool
A study of the impact of the means of grounding on the voltage sag and swell characterization is presented in this paper. Only temporary overvoltages and undervoltages caused by faults are considered. The voltage divider model is employed, and the symmetrical components are used to obtain the phasor voltages at the point of common coupling as functions of the means of grounding of the system and the distance between the point of common coupling and the fault location. A computational tool that shows the phasor behavior during a fault event is developed. Also, a zone classification is proposed based on the location of voltage vectors depending on the fault type. This zone classification may be a cornerstone for new methods of fault classification and location in future works.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Simulation interface to reproduce signals with harmonic distortion of distribution systems in real-time Adaptive model for a variable load in a distribution network using a neuro-fuzzy system A procedure for power electronic converters design with controllability verification based on the nonlinear dynamical model OpenDSS and OpenDSS-PM open source libraries for NI LabVIEW Implicit PV cell parameters estimation used in approximated closed-form model for inverter power control
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1