{"title":"3.0T MR高b值DWIBS对脑转移灶的检测价值","authors":"Y. Wang, Qin-yan Xu, Ye Zhang, Xi-zhen Wang, Xi-he Sun, Yue Guan, Yan-ming Ge, Guang-hui Chang","doi":"10.1109/BMEI.2015.7401484","DOIUrl":null,"url":null,"abstract":"Comparing the imaging features on the ordinary fa-value and high-b-value DWIBS with that on the enhanced imaging, to explore the value of 3.0T MR high-b-value diffusion weighted imaging with background suppression (DWIBS) in detecting the cerebral metastases. 41 patients with cerebral metastases confirmed by clinically and pathologically were collected. All the patients underwent conventional MRI and contrast-enhanced MRI, and DWIBS used two types b-value: ordinary b-value (b=0, 1000s/mm2) and high-b-value (b=3000s/mm2). Evading cystic necrosis area, the signal intensity (SI), background noise and apparent diffusion coefficient (ADC) value of tumor parenchyma and adjacent normal white matter were measured. The averages of signal to noise ratio (SNR), contrast to noise ratio (CNR) and contrast ratio (CR) were computed from these data. The lesion diagnosis accuracy rate of high-b-value DWIBS was better than that of ordinary b-value. On high-b-value DWIBS sequence, the CNR, CR and SI-lesion/ SI-normal of brain metastasis was significant higher than that of ordinary b-value DWIBS sequence (P<;0.05). And the SNR was significant lower than that of ordinary b-value DWIBS sequence (P <; 0.05). The CNR, CR of Contrast-enhanced T1WI was significant higher than that of normal brain tissue (P<;0.05). The ADC value in High-b-value DWIBS sequence was lower than that in ordinary b-value DWIBS sequence (P <; 0.05). Conclusion High-b-value DWIBS sequence showed a great value in detecting cerebral metastases. It was a simple method and could be avoiding potential harm of contrast agent for the human bodies.","PeriodicalId":119361,"journal":{"name":"2015 8th International Conference on Biomedical Engineering and Informatics (BMEI)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The value of 3.0T MR high-b-value DWIBS in detecting the cerebral metastases\",\"authors\":\"Y. Wang, Qin-yan Xu, Ye Zhang, Xi-zhen Wang, Xi-he Sun, Yue Guan, Yan-ming Ge, Guang-hui Chang\",\"doi\":\"10.1109/BMEI.2015.7401484\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Comparing the imaging features on the ordinary fa-value and high-b-value DWIBS with that on the enhanced imaging, to explore the value of 3.0T MR high-b-value diffusion weighted imaging with background suppression (DWIBS) in detecting the cerebral metastases. 41 patients with cerebral metastases confirmed by clinically and pathologically were collected. All the patients underwent conventional MRI and contrast-enhanced MRI, and DWIBS used two types b-value: ordinary b-value (b=0, 1000s/mm2) and high-b-value (b=3000s/mm2). Evading cystic necrosis area, the signal intensity (SI), background noise and apparent diffusion coefficient (ADC) value of tumor parenchyma and adjacent normal white matter were measured. The averages of signal to noise ratio (SNR), contrast to noise ratio (CNR) and contrast ratio (CR) were computed from these data. The lesion diagnosis accuracy rate of high-b-value DWIBS was better than that of ordinary b-value. On high-b-value DWIBS sequence, the CNR, CR and SI-lesion/ SI-normal of brain metastasis was significant higher than that of ordinary b-value DWIBS sequence (P<;0.05). And the SNR was significant lower than that of ordinary b-value DWIBS sequence (P <; 0.05). The CNR, CR of Contrast-enhanced T1WI was significant higher than that of normal brain tissue (P<;0.05). The ADC value in High-b-value DWIBS sequence was lower than that in ordinary b-value DWIBS sequence (P <; 0.05). Conclusion High-b-value DWIBS sequence showed a great value in detecting cerebral metastases. It was a simple method and could be avoiding potential harm of contrast agent for the human bodies.\",\"PeriodicalId\":119361,\"journal\":{\"name\":\"2015 8th International Conference on Biomedical Engineering and Informatics (BMEI)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 8th International Conference on Biomedical Engineering and Informatics (BMEI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BMEI.2015.7401484\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 8th International Conference on Biomedical Engineering and Informatics (BMEI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BMEI.2015.7401484","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对比普通fa值、高b值DWIBS与增强成像的影像特征,探讨3.0T MR背景抑制高b值弥散加权成像(DWIBS)对脑转移灶的检测价值。收集经临床及病理证实的41例脑转移瘤患者。所有患者均行常规MRI和增强MRI检查,DWIBS采用普通b值(b= 0.1000 s/mm2)和高b值(b=3000s/mm2)两种b值类型。避开囊性坏死区,测量肿瘤实质及邻近正常白质的信号强度(SI)、背景噪声及表观扩散系数(ADC)值。根据这些数据计算信噪比(SNR)、噪声对比比(CNR)和对比度(CR)的平均值。高b值DWIBS病变诊断准确率优于普通b值DWIBS。高b值DWIBS序列脑转移灶的CNR、CR、si -病变/ si -正常值均显著高于普通b值DWIBS序列(P< 0.05)。信噪比显著低于普通b值DWIBS序列(P <;0.05)。T1WI增强脑组织的CNR、CR显著高于正常脑组织(P<;0.05)。高b值DWIBS序列的ADC值低于普通b值DWIBS序列(P <;0.05)。结论高b值DWIBS序列对脑转移瘤的检测具有重要价值。该方法简便,可避免造影剂对人体的潜在危害。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The value of 3.0T MR high-b-value DWIBS in detecting the cerebral metastases
Comparing the imaging features on the ordinary fa-value and high-b-value DWIBS with that on the enhanced imaging, to explore the value of 3.0T MR high-b-value diffusion weighted imaging with background suppression (DWIBS) in detecting the cerebral metastases. 41 patients with cerebral metastases confirmed by clinically and pathologically were collected. All the patients underwent conventional MRI and contrast-enhanced MRI, and DWIBS used two types b-value: ordinary b-value (b=0, 1000s/mm2) and high-b-value (b=3000s/mm2). Evading cystic necrosis area, the signal intensity (SI), background noise and apparent diffusion coefficient (ADC) value of tumor parenchyma and adjacent normal white matter were measured. The averages of signal to noise ratio (SNR), contrast to noise ratio (CNR) and contrast ratio (CR) were computed from these data. The lesion diagnosis accuracy rate of high-b-value DWIBS was better than that of ordinary b-value. On high-b-value DWIBS sequence, the CNR, CR and SI-lesion/ SI-normal of brain metastasis was significant higher than that of ordinary b-value DWIBS sequence (P<;0.05). And the SNR was significant lower than that of ordinary b-value DWIBS sequence (P <; 0.05). The CNR, CR of Contrast-enhanced T1WI was significant higher than that of normal brain tissue (P<;0.05). The ADC value in High-b-value DWIBS sequence was lower than that in ordinary b-value DWIBS sequence (P <; 0.05). Conclusion High-b-value DWIBS sequence showed a great value in detecting cerebral metastases. It was a simple method and could be avoiding potential harm of contrast agent for the human bodies.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
ECG signal compressed sensing using the wavelet tree model Development of a quantifiable optical reader for lateral flow immunoassay A tightly secure multi-party-signature protocol in the plain model Breast mass detection with kernelized supervised hashing 3D reconstruction of human enamel Ex vivo using high frequency ultrasound
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1