P. Latha, Victoria Jancee, K. Kaviyarasan, S. Aghalya, J. Martin, L. Manickam
{"title":"使用物联网的可重构故障电流检测系统","authors":"P. Latha, Victoria Jancee, K. Kaviyarasan, S. Aghalya, J. Martin, L. Manickam","doi":"10.1109/ICECAA58104.2023.10212218","DOIUrl":null,"url":null,"abstract":"This research study intends to develop a novel method for identifying over-current or fault-current concerns in appliances and electronics used in the home or industry, such as battery and chargers is discussed. The system monitors electrical circuits in real-time, detects faults, and alerts appropriate parties through sound alarms and email notifications. The system may be configured according to individual defect detection needs. The NIOS II (Altera DE2 EDK) processor controls the numerous components and processes and analyzes data. To properly monitor electrical characteristics, voltage, and current sensors are added into the system. The NIOS II processor continually monitors observed data and compares them to specified threshold levels. An alarm sounds if voltage or current exceeds the thresholds, communicating an issue or abnormal situation. Through IoT server connectivity, the system sends email notifications in addition to the sound alert. An email notice is sent to a predetermined email address when a fault condition is detected, providing remote monitoring and quick information about the fault occurrence. The system's benefits include reconfigurability, monitoring in real-time, alarm alerting, remote email notification, safety, and customization.","PeriodicalId":114624,"journal":{"name":"2023 2nd International Conference on Edge Computing and Applications (ICECAA)","volume":"325-326 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reconfigurable Fault Current Detection System Using IoT\",\"authors\":\"P. Latha, Victoria Jancee, K. Kaviyarasan, S. Aghalya, J. Martin, L. Manickam\",\"doi\":\"10.1109/ICECAA58104.2023.10212218\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This research study intends to develop a novel method for identifying over-current or fault-current concerns in appliances and electronics used in the home or industry, such as battery and chargers is discussed. The system monitors electrical circuits in real-time, detects faults, and alerts appropriate parties through sound alarms and email notifications. The system may be configured according to individual defect detection needs. The NIOS II (Altera DE2 EDK) processor controls the numerous components and processes and analyzes data. To properly monitor electrical characteristics, voltage, and current sensors are added into the system. The NIOS II processor continually monitors observed data and compares them to specified threshold levels. An alarm sounds if voltage or current exceeds the thresholds, communicating an issue or abnormal situation. Through IoT server connectivity, the system sends email notifications in addition to the sound alert. An email notice is sent to a predetermined email address when a fault condition is detected, providing remote monitoring and quick information about the fault occurrence. The system's benefits include reconfigurability, monitoring in real-time, alarm alerting, remote email notification, safety, and customization.\",\"PeriodicalId\":114624,\"journal\":{\"name\":\"2023 2nd International Conference on Edge Computing and Applications (ICECAA)\",\"volume\":\"325-326 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 2nd International Conference on Edge Computing and Applications (ICECAA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICECAA58104.2023.10212218\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 2nd International Conference on Edge Computing and Applications (ICECAA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECAA58104.2023.10212218","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
本研究旨在开发一种新的方法来识别家庭或工业中使用的电器和电子产品中的过流或故障电流问题,例如电池和充电器。系统对电路进行实时监控,及时发现故障,并通过声音报警、邮件通知等方式向相关方发出警报。系统可以根据单个缺陷检测的需要进行配置。NIOS II (Altera DE2 EDK)处理器控制众多组件和进程并分析数据。为了正确地监控电气特性,在系统中添加了电压和电流传感器。NIOS II处理器持续监视观察到的数据,并将它们与指定的阈值水平进行比较。当电压或电流超过阈值时发出告警,提示存在问题或异常情况。通过物联网服务器连接,系统除了发出声音警报外,还会发送电子邮件通知。当检测到故障情况时,通过邮件通知的方式发送到指定邮箱,实现远程监控和快速了解故障发生情况。该系统的优点包括可重构性、实时监控、警报警报、远程电子邮件通知、安全性和可定制性。
Reconfigurable Fault Current Detection System Using IoT
This research study intends to develop a novel method for identifying over-current or fault-current concerns in appliances and electronics used in the home or industry, such as battery and chargers is discussed. The system monitors electrical circuits in real-time, detects faults, and alerts appropriate parties through sound alarms and email notifications. The system may be configured according to individual defect detection needs. The NIOS II (Altera DE2 EDK) processor controls the numerous components and processes and analyzes data. To properly monitor electrical characteristics, voltage, and current sensors are added into the system. The NIOS II processor continually monitors observed data and compares them to specified threshold levels. An alarm sounds if voltage or current exceeds the thresholds, communicating an issue or abnormal situation. Through IoT server connectivity, the system sends email notifications in addition to the sound alert. An email notice is sent to a predetermined email address when a fault condition is detected, providing remote monitoring and quick information about the fault occurrence. The system's benefits include reconfigurability, monitoring in real-time, alarm alerting, remote email notification, safety, and customization.