用表面电极记录肌内肌电信号

N. Stoykov, Madeleine M. Lowery, C. J. Heckman, A. Taflove, Todd A. Kuiken
{"title":"用表面电极记录肌内肌电信号","authors":"N. Stoykov, Madeleine M. Lowery, C. J. Heckman, A. Taflove, Todd A. Kuiken","doi":"10.1109/ICORR.2005.1501104","DOIUrl":null,"url":null,"abstract":"The control of multifunctional myoelectric prostheses is a substantive area of research with the potential to dramatically improve the independence of transradial amputees. We present preliminary data for the development of a new technique for obtaining multiple electromyographic (EMG) signals for controlling multifunctional myoelectric hand and wrist prostheses. A completely embedded passive conductor is proposed to transmit intramuscular EMG signals to a distant location just beneath the skin surface with a subcutaneous terminal. These signals can then be recorded with conventional surface electrodes. The surface recorded intramuscular EMG (SRI EMG) signals would closely follow the electrical potential at the muscle fiber source. They would be extremely selective, and the well-known effect of spatial filtering, which reduces the amplitude and frequency content of surface EMG signals, would be virtually eliminated. It would, therefore, be possible to access control signals from deep or small muscles that would otherwise be unavailable. Based on this technique, a new generation of multifunction myoelectric prostheses can be developed. The technique is a simple, inexpensive, and robust alternative to implanted telemetry systems and percutaneous electrodes.","PeriodicalId":131431,"journal":{"name":"9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005.","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":"{\"title\":\"Recording intramuscular EMG signals using surface electrodes\",\"authors\":\"N. Stoykov, Madeleine M. Lowery, C. J. Heckman, A. Taflove, Todd A. Kuiken\",\"doi\":\"10.1109/ICORR.2005.1501104\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The control of multifunctional myoelectric prostheses is a substantive area of research with the potential to dramatically improve the independence of transradial amputees. We present preliminary data for the development of a new technique for obtaining multiple electromyographic (EMG) signals for controlling multifunctional myoelectric hand and wrist prostheses. A completely embedded passive conductor is proposed to transmit intramuscular EMG signals to a distant location just beneath the skin surface with a subcutaneous terminal. These signals can then be recorded with conventional surface electrodes. The surface recorded intramuscular EMG (SRI EMG) signals would closely follow the electrical potential at the muscle fiber source. They would be extremely selective, and the well-known effect of spatial filtering, which reduces the amplitude and frequency content of surface EMG signals, would be virtually eliminated. It would, therefore, be possible to access control signals from deep or small muscles that would otherwise be unavailable. Based on this technique, a new generation of multifunction myoelectric prostheses can be developed. The technique is a simple, inexpensive, and robust alternative to implanted telemetry systems and percutaneous electrodes.\",\"PeriodicalId\":131431,\"journal\":{\"name\":\"9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005.\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-08-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICORR.2005.1501104\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICORR.2005.1501104","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

摘要

多功能肌电义肢的控制是一个实质性的研究领域,具有显著提高经桡骨截肢者独立性的潜力。我们提供了一种获取多种肌电信号的新技术的初步数据,用于控制多功能肌电手和腕部假体。提出了一种完全嵌入的无源导体,通过皮下终端将肌内肌电图信号传输到皮肤表面下的远处。这些信号可以用传统的表面电极记录下来。表面记录的肌内肌电(SRI EMG)信号与肌纤维源电位密切相关。它们将具有极强的选择性,而众所周知的空间滤波效应,即降低表面肌电信号的幅度和频率含量,将几乎被消除。因此,从深层或小肌肉中获取控制信号是可能的,否则这些信号是无法获得的。在此基础上,可研制新一代多功能肌电义肢。该技术是一种简单、廉价、可靠的替代植入式遥测系统和经皮电极的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Recording intramuscular EMG signals using surface electrodes
The control of multifunctional myoelectric prostheses is a substantive area of research with the potential to dramatically improve the independence of transradial amputees. We present preliminary data for the development of a new technique for obtaining multiple electromyographic (EMG) signals for controlling multifunctional myoelectric hand and wrist prostheses. A completely embedded passive conductor is proposed to transmit intramuscular EMG signals to a distant location just beneath the skin surface with a subcutaneous terminal. These signals can then be recorded with conventional surface electrodes. The surface recorded intramuscular EMG (SRI EMG) signals would closely follow the electrical potential at the muscle fiber source. They would be extremely selective, and the well-known effect of spatial filtering, which reduces the amplitude and frequency content of surface EMG signals, would be virtually eliminated. It would, therefore, be possible to access control signals from deep or small muscles that would otherwise be unavailable. Based on this technique, a new generation of multifunction myoelectric prostheses can be developed. The technique is a simple, inexpensive, and robust alternative to implanted telemetry systems and percutaneous electrodes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A dual input device for self-assisted control of a virtual pendulum Realizing a posture-based wearable antigravity muscles support system for lower extremities Adjustable robotic tendon using a 'Jack Spring'/spl trade/ A 3-D rehabilitation system for upper limbs developed in a 5-year NEDO project and its clinical testing A motorized gravity compensation mechanism used for active rehabilitation of upper limbs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1