低压配电电缆局部缺陷检测

Merse Szalai, László Székely, R. Cselkó
{"title":"低压配电电缆局部缺陷检测","authors":"Merse Szalai, László Székely, R. Cselkó","doi":"10.1109/IYCE54153.2022.9857547","DOIUrl":null,"url":null,"abstract":"The detectability of fault locations in low voltage distribution cables were not evolved as much as in higher voltage levels. The goal of our work is to find a similar method to detect defects in the low voltage distribution system. One possible method is the detection of intermittent arcing, which is a clear sign of ongoing degradation. We should be able to determine where discharges occur in the grid. We present an attempt to apply smart meters to detect the defects, as this would easily allow to alert the system operator. In this study we investigated fault-free and intentionally damaged underground cables. Our goal was to show that we can distinguish the current or voltage signals caused by discharges via smart meters on damaged cables from the completely intact cables.","PeriodicalId":248738,"journal":{"name":"2022 8th International Youth Conference on Energy (IYCE)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Detection of local defects in low-voltage distribution cables\",\"authors\":\"Merse Szalai, László Székely, R. Cselkó\",\"doi\":\"10.1109/IYCE54153.2022.9857547\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The detectability of fault locations in low voltage distribution cables were not evolved as much as in higher voltage levels. The goal of our work is to find a similar method to detect defects in the low voltage distribution system. One possible method is the detection of intermittent arcing, which is a clear sign of ongoing degradation. We should be able to determine where discharges occur in the grid. We present an attempt to apply smart meters to detect the defects, as this would easily allow to alert the system operator. In this study we investigated fault-free and intentionally damaged underground cables. Our goal was to show that we can distinguish the current or voltage signals caused by discharges via smart meters on damaged cables from the completely intact cables.\",\"PeriodicalId\":248738,\"journal\":{\"name\":\"2022 8th International Youth Conference on Energy (IYCE)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 8th International Youth Conference on Energy (IYCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IYCE54153.2022.9857547\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 8th International Youth Conference on Energy (IYCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IYCE54153.2022.9857547","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

低压配电电缆故障定位的可检测性发展不如高压配电电缆。我们的工作目标是寻找一种类似的方法来检测低压配电系统中的缺陷。一种可能的方法是检测间歇性电弧,这是持续退化的明显迹象。我们应该能确定电网中发生放电的位置。我们尝试应用智能仪表来检测缺陷,因为这很容易提醒系统操作员。在这项研究中,我们调查了无故障和故意损坏的地下电缆。我们的目标是表明,我们可以通过智能仪表区分损坏电缆上放电引起的电流或电压信号和完全完好的电缆。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Detection of local defects in low-voltage distribution cables
The detectability of fault locations in low voltage distribution cables were not evolved as much as in higher voltage levels. The goal of our work is to find a similar method to detect defects in the low voltage distribution system. One possible method is the detection of intermittent arcing, which is a clear sign of ongoing degradation. We should be able to determine where discharges occur in the grid. We present an attempt to apply smart meters to detect the defects, as this would easily allow to alert the system operator. In this study we investigated fault-free and intentionally damaged underground cables. Our goal was to show that we can distinguish the current or voltage signals caused by discharges via smart meters on damaged cables from the completely intact cables.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Numerical study of a duct-type ESP with W-type collecting electrodes and different circular corona electrodes radius Examination of electric field distribution in a laboratory-built electrospinning device Overview of the EROI, a tool to measure energy availability through the energy transition Developing a residential consumption forecast method Utilization of Additive Manufacturing in Nuclear Power Industry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1