M. Young, A. Dimitrovski, Zhi Li, Yilu Liu, R. Patterson
{"title":"连续可变串联电抗器:ccvt对距离保护的影响","authors":"M. Young, A. Dimitrovski, Zhi Li, Yilu Liu, R. Patterson","doi":"10.1109/PESGM.2015.7286460","DOIUrl":null,"url":null,"abstract":"A continuously variable series reactor (CVSR) is a novel application of a well-known concept that provides continuous modulation of line reactance by controlling the magnetization in a ferromagnetic core. The target application is power flow control in meshed electric power systems. Modulation of the line impedance occurs by altering the bias of a dc winding to control the magnetization of the ferromagnetic core, thereby varying the reactance of the ac winding. Fault conditions can drive the CVSR outside of the control point in sub-cycle time and could affect distance protection along the controlled line. This study seeks to quantify such impacts using PSCAD™ simulations of a CVSR under fault conditions with CCVTs providing the line potential measurements. Impacts are observed through playback of the resulting waveforms into a distance relay. The results show that the interaction of the CVSR with CCVTs has minimal effect on distance protection reach.","PeriodicalId":423639,"journal":{"name":"2015 IEEE Power & Energy Society General Meeting","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Continously variable series reactor: Impacts on distance protection using CCVTs\",\"authors\":\"M. Young, A. Dimitrovski, Zhi Li, Yilu Liu, R. Patterson\",\"doi\":\"10.1109/PESGM.2015.7286460\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A continuously variable series reactor (CVSR) is a novel application of a well-known concept that provides continuous modulation of line reactance by controlling the magnetization in a ferromagnetic core. The target application is power flow control in meshed electric power systems. Modulation of the line impedance occurs by altering the bias of a dc winding to control the magnetization of the ferromagnetic core, thereby varying the reactance of the ac winding. Fault conditions can drive the CVSR outside of the control point in sub-cycle time and could affect distance protection along the controlled line. This study seeks to quantify such impacts using PSCAD™ simulations of a CVSR under fault conditions with CCVTs providing the line potential measurements. Impacts are observed through playback of the resulting waveforms into a distance relay. The results show that the interaction of the CVSR with CCVTs has minimal effect on distance protection reach.\",\"PeriodicalId\":423639,\"journal\":{\"name\":\"2015 IEEE Power & Energy Society General Meeting\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Power & Energy Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESGM.2015.7286460\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Power & Energy Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM.2015.7286460","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Continously variable series reactor: Impacts on distance protection using CCVTs
A continuously variable series reactor (CVSR) is a novel application of a well-known concept that provides continuous modulation of line reactance by controlling the magnetization in a ferromagnetic core. The target application is power flow control in meshed electric power systems. Modulation of the line impedance occurs by altering the bias of a dc winding to control the magnetization of the ferromagnetic core, thereby varying the reactance of the ac winding. Fault conditions can drive the CVSR outside of the control point in sub-cycle time and could affect distance protection along the controlled line. This study seeks to quantify such impacts using PSCAD™ simulations of a CVSR under fault conditions with CCVTs providing the line potential measurements. Impacts are observed through playback of the resulting waveforms into a distance relay. The results show that the interaction of the CVSR with CCVTs has minimal effect on distance protection reach.