新型4型风力发电机保护方案

Shashidhar Reddy Sathu, N. Fischer, B. Johnson
{"title":"新型4型风力发电机保护方案","authors":"Shashidhar Reddy Sathu, N. Fischer, B. Johnson","doi":"10.1109/CPRE.2018.8349812","DOIUrl":null,"url":null,"abstract":"The short circuit behavior of the early generation wind turbines depends solely on the physical characteristics of the machine. Conventional protection schemes can be applied to provide protection to those wind farms. But full converter based Type 4 wind turbine generators have complex fault current characteristics governed by the converter controls, with fault current responses very different from synchronous generators. The use of relays with conventional protection and supervision schemes may cause misoperation. This paper presents preliminary concepts for a new protection scheme based on converter control system behavior and tested with simulation of a Type 4 wind turbine in RTDS.","PeriodicalId":285875,"journal":{"name":"2018 71st Annual Conference for Protective Relay Engineers (CPRE)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"New protection scheme for type 4 wind turbines\",\"authors\":\"Shashidhar Reddy Sathu, N. Fischer, B. Johnson\",\"doi\":\"10.1109/CPRE.2018.8349812\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The short circuit behavior of the early generation wind turbines depends solely on the physical characteristics of the machine. Conventional protection schemes can be applied to provide protection to those wind farms. But full converter based Type 4 wind turbine generators have complex fault current characteristics governed by the converter controls, with fault current responses very different from synchronous generators. The use of relays with conventional protection and supervision schemes may cause misoperation. This paper presents preliminary concepts for a new protection scheme based on converter control system behavior and tested with simulation of a Type 4 wind turbine in RTDS.\",\"PeriodicalId\":285875,\"journal\":{\"name\":\"2018 71st Annual Conference for Protective Relay Engineers (CPRE)\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 71st Annual Conference for Protective Relay Engineers (CPRE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPRE.2018.8349812\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 71st Annual Conference for Protective Relay Engineers (CPRE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPRE.2018.8349812","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

早期风力涡轮机的短路行为完全取决于机器的物理特性。传统的保护方案可以为这些风力发电场提供保护。但基于全变流器的四型风力发电机组故障电流特性复杂,受变流器控制,故障电流响应与同步发电机有很大不同。使用具有常规保护和监督方案的继电器可能会导致误操作。本文提出了一种基于变流器控制系统行为的新型保护方案的初步概念,并在RTDS中对4型风力机进行了仿真试验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
New protection scheme for type 4 wind turbines
The short circuit behavior of the early generation wind turbines depends solely on the physical characteristics of the machine. Conventional protection schemes can be applied to provide protection to those wind farms. But full converter based Type 4 wind turbine generators have complex fault current characteristics governed by the converter controls, with fault current responses very different from synchronous generators. The use of relays with conventional protection and supervision schemes may cause misoperation. This paper presents preliminary concepts for a new protection scheme based on converter control system behavior and tested with simulation of a Type 4 wind turbine in RTDS.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Correlating protective relay reports for system-wide, post-event analysis Back to the basics — Event analysis using symmetrical components Cyber security — Securing the protection and control relay communication in substation Communications assisted islanding detection: Contrasting direct transfer trip and phase comparison methods Applying intelligent fast load shed using IEC 61850 GOOSE
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1