{"title":"智能电网重构过程中谐波失真极限变化研究","authors":"Wenyue Yang, D. Geiger, S. Halpin","doi":"10.1109/NAPS.2014.6965421","DOIUrl":null,"url":null,"abstract":"It is of interest to determine if the applicable harmonic distortion limits of customer installations will change after the smart grid reconfigures the power system. There is wide acceptance that the smart grid will improve the power system by making it more efficient, reliable, and secure. However, there may be appreciable changes to the applicable harmonic distortion limits of the customer installations when the smart grid reconfigures the power system bus connections. This phenomenon may be an issue of concern in implementing smart grid technologies. A 30-bus power system will be used as the test system to determine if the customer's harmonic distortion limits will vary based on how the power system is connected. The variations in the harmonic distortion limit for various customers will be collected, analyzed and presented. It will be shown that the smart grid reconfiguration process will change the harmonic distortion limits of some of the customer installations. Future standardization will need to account for this phenomenon so that the power system will continue to operate in an efficient, reliable, and secure manner.","PeriodicalId":421766,"journal":{"name":"2014 North American Power Symposium (NAPS)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A study of harmonic distortion limit changes during the reconfiguration process of the smart grid\",\"authors\":\"Wenyue Yang, D. Geiger, S. Halpin\",\"doi\":\"10.1109/NAPS.2014.6965421\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"It is of interest to determine if the applicable harmonic distortion limits of customer installations will change after the smart grid reconfigures the power system. There is wide acceptance that the smart grid will improve the power system by making it more efficient, reliable, and secure. However, there may be appreciable changes to the applicable harmonic distortion limits of the customer installations when the smart grid reconfigures the power system bus connections. This phenomenon may be an issue of concern in implementing smart grid technologies. A 30-bus power system will be used as the test system to determine if the customer's harmonic distortion limits will vary based on how the power system is connected. The variations in the harmonic distortion limit for various customers will be collected, analyzed and presented. It will be shown that the smart grid reconfiguration process will change the harmonic distortion limits of some of the customer installations. Future standardization will need to account for this phenomenon so that the power system will continue to operate in an efficient, reliable, and secure manner.\",\"PeriodicalId\":421766,\"journal\":{\"name\":\"2014 North American Power Symposium (NAPS)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 North American Power Symposium (NAPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAPS.2014.6965421\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 North American Power Symposium (NAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.2014.6965421","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

确定在智能电网重新配置电力系统后,客户装置的适用谐波失真限制是否会发生变化是一个有趣的问题。人们普遍认为,智能电网将提高电力系统的效率、可靠性和安全性。然而,当智能电网重新配置电力系统母线连接时,客户装置的适用谐波失真限制可能会有明显的变化。这种现象可能是实施智能电网技术时需要关注的问题。将使用一个30总线的电力系统作为测试系统,以确定客户的谐波失真限制是否会根据电力系统的连接方式而变化。收集、分析和呈现不同用户的谐波失真极限变化。结果表明,智能电网重构过程将改变部分用户装置的谐波失真限制。未来的标准化将需要考虑到这一现象,以便电力系统能够继续以高效、可靠和安全的方式运行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A study of harmonic distortion limit changes during the reconfiguration process of the smart grid
It is of interest to determine if the applicable harmonic distortion limits of customer installations will change after the smart grid reconfigures the power system. There is wide acceptance that the smart grid will improve the power system by making it more efficient, reliable, and secure. However, there may be appreciable changes to the applicable harmonic distortion limits of the customer installations when the smart grid reconfigures the power system bus connections. This phenomenon may be an issue of concern in implementing smart grid technologies. A 30-bus power system will be used as the test system to determine if the customer's harmonic distortion limits will vary based on how the power system is connected. The variations in the harmonic distortion limit for various customers will be collected, analyzed and presented. It will be shown that the smart grid reconfiguration process will change the harmonic distortion limits of some of the customer installations. Future standardization will need to account for this phenomenon so that the power system will continue to operate in an efficient, reliable, and secure manner.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Addressing cyber security for the oil, gas and energy sector Investigation of voltage stability in three-phase unbalanced distribution systems with DG using modal analysis technique Dynamic Remedial Action Scheme using online transient stability analysis Implementing a real-time cyber-physical system test bed in RTDS and OPNET Size reduction of permanent magnet generators for wind turbines with higher energy density permanent magnets
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1